Summary

Details

Page properties
Content
... ... @@ -12,6 +12,8 @@
12 12  |Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 32
13 13  |Mounting dimensions (length × width), mm|(% style="width:178px" %)114 × 114
14 14  |Mounting holes|(% style="width:178px" %)M3
15 +|Headers P1, P6-P9 type |(% style="width:178px" %)Molex series Mini-Fit
16 +|Headers P11-P15 type |(% style="width:178px" %)Molex series Micro-Fit
15 15  
16 16  == Connection procedure ==
17 17  
... ... @@ -89,7 +89,7 @@
89 89  By default, relay 1 is used to control the discharging contactor.
90 90  
91 91  |**Pin**|**Name**|**Description**
92 -|**1**|**V+**|Switching voltage (up to 55V, max 3A)
94 +|**1**|**V+**|Switching voltage (up to 55V, max 2A)
93 93  |**2**|**NO**|Normally open contact
94 94  
95 95  === P9 – header of relay 2 ===
... ... @@ -101,7 +101,7 @@
101 101  By default, relay 2 is used to output the “Allow charging” signal.
102 102  
103 103  |**Pin**|**Name**|**Description**
104 -|**1**|**V+**|Switching voltage (up to 55V, max 3A)
106 +|**1**|**V+**|Switching voltage (up to 55V, max 2A)
105 105  |**2**|**NO**|Normally open contact
106 106  
107 107  === P6 – header of relay 3 ===
... ... @@ -113,8 +113,7 @@
113 113  By default, relay 3 is used to control the charging contactor.
114 114  
115 115  |**Pin**|**Name**|**Description**
116 -|**1**|**V+**|Switching voltage up to 55V,
117 -up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c)
118 +|**1**|**V+**|Switching voltage (up to 55V, max 8A)
118 118  |**2**|**NO**|Normally open contact
119 119  
120 120  === P7 – header of relay 4 ===
... ... @@ -126,8 +126,7 @@
126 126  By default, relay 4 is used to control the heater.
127 127  
128 128  |**Pin**|**Name**|**Description**
129 -|**1**|**V+**|Switching voltage up to 55V,
130 -up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c)
130 +|**1**|**V+**|Switching voltage (up to 55V, max 8A)
131 131  |**2**|**NO**|Normally open contact
132 132  
133 133  === P14 – header for CAN and RS-485 interfaces ===