Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 6 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,15 +1,31 @@ 1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Installation and connection = 3 3 4 +== Safety rules == 5 + 6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor** able to break the load and charge circuits must be connected to the BMS. 7 + 8 +Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured. 9 + 10 +(% class="box errormessage" %) 11 +((( 12 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 13 +))) 14 + 15 +(% class="box errormessage" %) 16 +((( 17 +The system is not designed to operate with batteries whose total voltage exceeds 1200 V. 18 +))) 19 + 4 4 == Installation procedure == 5 5 6 6 Overall and mounting dimensions of the BMS Main 2.1 are shown below. 7 7 8 -[[image:17 32198397369-222.png||data-xwiki-image-style-alignment="center" height="393" width="556"]]24 +[[image:1752600650898-961.png||data-xwiki-image-style-alignment="center" height="546" width="450"]] 9 9 10 10 (% style="width:494px" %) 11 11 |**Parameter**|(% style="width:178px" %)**Value** 12 -|Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 3228 +|Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 17 13 13 |Mounting dimensions (length × width), mm|(% style="width:178px" %)114 × 114 14 14 |Mounting holes|(% style="width:178px" %)M3 15 15 ... ... @@ -89,9 +89,13 @@ 89 89 By default, relay 1 is used to control the discharging contactor. 90 90 91 91 |**Pin**|**Name**|**Description** 92 -|**1**|**V+**|Switching voltage (up to 55V, max 2A)108 +|**1**|**V+**|Switching voltage (up to 55V, max 3A) 93 93 |**2**|**NO**|Normally open contact 94 94 111 +Contactor connection example for all relays: 112 + 113 +[[image:1741619814065-850.png||height="189" width="252"]] 114 + 95 95 === P9 – header of relay 2 === 96 96 97 97 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -101,9 +101,11 @@ 101 101 By default, relay 2 is used to output the “Allow charging” signal. 102 102 103 103 |**Pin**|**Name**|**Description** 104 -|**1**|**V+**|Switching voltage (up to 55V, max 2A)124 +|**1**|**V+**|Switching voltage (up to 55V, max 3A) 105 105 |**2**|**NO**|Normally open contact 106 106 127 +Contactor connection example: see relay 1. 128 + 107 107 === P6 – header of relay 3 === 108 108 109 109 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -113,9 +113,12 @@ 113 113 By default, relay 3 is used to control the charging contactor. 114 114 115 115 |**Pin**|**Name**|**Description** 116 -|**1**|**V+**|Switching voltage (up to 55V, max 8A) 138 +|**1**|**V+**|Switching voltage up to 55V, 139 +up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 117 117 |**2**|**NO**|Normally open contact 118 118 142 +Contactor connection example: see relay 1. 143 + 119 119 === P7 – header of relay 4 === 120 120 121 121 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -125,9 +125,12 @@ 125 125 By default, relay 4 is used to control the heater. 126 126 127 127 |**Pin**|**Name**|**Description** 128 -|**1**|**V+**|Switching voltage (up to 55V, max 8A) 153 +|**1**|**V+**|Switching voltage up to 55V, 154 +up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 129 129 |**2**|**NO**|Normally open contact 130 130 157 +Contactor connection example: see relay 1. 158 + 131 131 === P14 – header for CAN and RS-485 interfaces === 132 132 133 133 Receptacle Housing: Molex 430250600. Terminals: Molex 43030
- 1741619628288-759.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.2 KB - Content
- 1741619637854-961.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.2 KB - Content
- 1741619700532-367.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.1 KB - Content
- 1741619814065-850.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.1 KB - Content
- 1741620022836-867.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.3 KB - Content
- 1752600650898-961.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +84.9 KB - Content