... ... @@ -89,9 +89,13 @@ 89 89 By default, relay 1 is used to control the discharging contactor. 90 90 91 91 |**Pin**|**Name**|**Description** 92 -|**1**|**V+**|Switching voltage (up to 55V, max 2A)92 +|**1**|**V+**|Switching voltage (up to 55V, max 3A) 93 93 |**2**|**NO**|Normally open contact 94 94 95 +Contactor connection example for all relays: 96 + 97 +[[image:1741619814065-850.png||height="189" width="252"]] 98 + 95 95 === P9 – header of relay 2 === 96 96 97 97 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -101,9 +101,11 @@ 101 101 By default, relay 2 is used to output the “Allow charging” signal. 102 102 103 103 |**Pin**|**Name**|**Description** 104 -|**1**|**V+**|Switching voltage (up to 55V, max 2A)108 +|**1**|**V+**|Switching voltage (up to 55V, max 3A) 105 105 |**2**|**NO**|Normally open contact 106 106 111 +Contactor connection example: see relay 1. 112 + 107 107 === P6 – header of relay 3 === 108 108 109 109 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -113,9 +113,12 @@ 113 113 By default, relay 3 is used to control the charging contactor. 114 114 115 115 |**Pin**|**Name**|**Description** 116 -|**1**|**V+**|Switching voltage (up to 55V, max 8A) 122 +|**1**|**V+**|Switching voltage up to 55V, 123 +up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 117 117 |**2**|**NO**|Normally open contact 118 118 126 +Contactor connection example: see relay 1. 127 + 119 119 === P7 – header of relay 4 === 120 120 121 121 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -125,9 +125,12 @@ 125 125 By default, relay 4 is used to control the heater. 126 126 127 127 |**Pin**|**Name**|**Description** 128 -|**1**|**V+**|Switching voltage (up to 55V, max 8A) 137 +|**1**|**V+**|Switching voltage up to 55V, 138 +up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 129 129 |**2**|**NO**|Normally open contact 130 130 141 +Contactor connection example: see relay 1. 142 + 131 131 === P14 – header for CAN and RS-485 interfaces === 132 132 133 133 Receptacle Housing: Molex 430250600. Terminals: Molex 43030
- 1741619628288-759.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.2 KB - Content
- 1741619637854-961.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.2 KB - Content
- 1741619700532-367.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.1 KB - Content
- 1741619814065-850.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.1 KB - Content