... ... @@ -89,7 +89,7 @@
89 89  By default, relay 1 is used to control the discharging contactor.
90 90  
91 91  |**Pin**|**Name**|**Description**
92 -|**1**|**V+**|Switching voltage (up to 55V, max 2A)
92 +|**1**|**V+**|Switching voltage (up to 55V, max 3A)
93 93  |**2**|**NO**|Normally open contact
94 94  
95 95  === P9 – header of relay 2 ===
... ... @@ -101,7 +101,7 @@
101 101  By default, relay 2 is used to output the “Allow charging” signal.
102 102  
103 103  |**Pin**|**Name**|**Description**
104 -|**1**|**V+**|Switching voltage (up to 55V, max 2A)
104 +|**1**|**V+**|Switching voltage (up to 55V, max 3A)
105 105  |**2**|**NO**|Normally open contact
106 106  
107 107  === P6 – header of relay 3 ===
... ... @@ -113,7 +113,8 @@
113 113  By default, relay 3 is used to control the charging contactor.
114 114  
115 115  |**Pin**|**Name**|**Description**
116 -|**1**|**V+**|Switching voltage (up to 55V, max 8A)
116 +|**1**|**V+**|Switching voltage up to 55V,
117 +up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c)
117 117  |**2**|**NO**|Normally open contact
118 118  
119 119  === P7 – header of relay 4 ===
... ... @@ -125,7 +125,8 @@
125 125  By default, relay 4 is used to control the heater.
126 126  
127 127  |**Pin**|**Name**|**Description**
128 -|**1**|**V+**|Switching voltage (up to 55V, max 8A)
129 +|**1**|**V+**|Switching voltage up to 55V,
130 +up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c)
129 129  |**2**|**NO**|Normally open contact
130 130  