... ... @@ -1,19 +1,32 @@
1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Installation and connection =
3 3  
4 +== Safety rules ==
5 +
6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor** able to break the load and charge circuits must be connected to the BMS.
7 +
8 +Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.
9 +
10 +(% class="box errormessage" %)
11 +(((
12 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
13 +)))
14 +
15 +(% class="box errormessage" %)
16 +(((
17 +The system is not designed to operate with batteries whose total voltage exceeds 1200 V.
18 +)))
19 +
4 4  == Installation procedure ==
5 5  
6 6  Overall and mounting dimensions of the BMS Main 2.1 are shown below.
7 7  
8 -[[image:1732198397369-222.png||data-xwiki-image-style-alignment="center" height="393" width="556"]]
9 9  
10 10  (% style="width:494px" %)
11 11  |**Parameter**|(% style="width:178px" %)**Value**
12 -|Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 32
27 +|Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 17
13 13  |Mounting dimensions (length × width), mm|(% style="width:178px" %)114 × 114
14 14  |Mounting holes|(% style="width:178px" %)M3
15 -|Headers P1, P6-P9 type |(% style="width:178px" %)Molex series Mini-Fit
16 -|Headers P11-P15 type |(% style="width:178px" %)Molex series Micro-Fit
17 17  
18 18  == Connection procedure ==
19 19  
... ... @@ -91,9 +91,13 @@
91 91  By default, relay 1 is used to control the discharging contactor.
92 92  
93 93  |**Pin**|**Name**|**Description**
94 -|**1**|**V+**|Switching voltage (up to 55V, max 2A)
107 +|**1**|**V+**|Switching voltage (up to 55V, max 3A)
95 95  |**2**|**NO**|Normally open contact
96 96  
110 +Contactor connection example for all relays:
111 +
112 +[[image:1741619814065-850.png||height="189" width="252"]]
113 +
97 97  === P9 – header of relay 2 ===
98 98  
99 99  Receptacle Housing: Molex 39012020. Terminals: Molex 5556
... ... @@ -103,9 +103,11 @@
103 103  By default, relay 2 is used to output the “Allow charging” signal.
104 104  
105 105  |**Pin**|**Name**|**Description**
106 -|**1**|**V+**|Switching voltage (up to 55V, max 2A)
123 +|**1**|**V+**|Switching voltage (up to 55V, max 3A)
107 107  |**2**|**NO**|Normally open contact
108 108  
126 +Contactor connection example: see relay 1.
127 +
109 109  === P6 – header of relay 3 ===
110 110  
111 111  Receptacle Housing: Molex 39012020. Terminals: Molex 5556
... ... @@ -115,9 +115,12 @@
115 115  By default, relay 3 is used to control the charging contactor.
116 116  
117 117  |**Pin**|**Name**|**Description**
118 -|**1**|**V+**|Switching voltage (up to 55V, max 8A)
137 +|**1**|**V+**|Switching voltage up to 55V,
138 +up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c)
119 119  |**2**|**NO**|Normally open contact
120 120  
141 +Contactor connection example: see relay 1.
142 +
121 121  === P7 – header of relay 4 ===
122 122  
123 123  Receptacle Housing: Molex 39012020. Terminals: Molex 5556
... ... @@ -127,9 +127,12 @@
127 127  By default, relay 4 is used to control the heater.
128 128  
129 129  |**Pin**|**Name**|**Description**
130 -|**1**|**V+**|Switching voltage (up to 55V, max 8A)
152 +|**1**|**V+**|Switching voltage up to 55V,
153 +up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c)
131 131  |**2**|**NO**|Normally open contact
132 132  
156 +Contactor connection example: see relay 1.
157 +
133 133  === P14 – header for CAN and RS-485 interfaces ===
134 134  
135 135  Receptacle Housing: Molex 430250600. Terminals: Molex 43030
1741619628288-759.jpg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +29.2 KB
Content
1741619637854-961.jpg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +29.2 KB
Content
1741619700532-367.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +14.1 KB
Content
1741619814065-850.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +15.1 KB
Content
1741620022836-867.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +13.3 KB
Content
1752600650898-961.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +84.9 KB
Content