... ... @@ -12,8 +12,6 @@
12 12  |Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 32
13 13  |Mounting dimensions (length × width), mm|(% style="width:178px" %)114 × 114
14 14  |Mounting holes|(% style="width:178px" %)M3
15 -|Headers P1, P6-P9 type |(% style="width:178px" %)Molex series Mini-Fit
16 -|Headers P11-P15 type |(% style="width:178px" %)Molex series Micro-Fit
17 17  
18 18  == Connection procedure ==
19 19  
... ... @@ -91,7 +91,7 @@
91 91  By default, relay 1 is used to control the discharging contactor.
92 92  
93 93  |**Pin**|**Name**|**Description**
94 -|**1**|**V+**|Switching voltage (up to 55V, max 2A)
92 +|**1**|**V+**|Switching voltage (up to 55V, max 3A)
95 95  |**2**|**NO**|Normally open contact
96 96  
97 97  === P9 – header of relay 2 ===
... ... @@ -103,7 +103,7 @@
103 103  By default, relay 2 is used to output the “Allow charging” signal.
104 104  
105 105  |**Pin**|**Name**|**Description**
106 -|**1**|**V+**|Switching voltage (up to 55V, max 2A)
104 +|**1**|**V+**|Switching voltage (up to 55V, max 3A)
107 107  |**2**|**NO**|Normally open contact
108 108  
109 109  === P6 – header of relay 3 ===
... ... @@ -115,7 +115,8 @@
115 115  By default, relay 3 is used to control the charging contactor.
116 116  
117 117  |**Pin**|**Name**|**Description**
118 -|**1**|**V+**|Switching voltage (up to 55V, max 8A)
116 +|**1**|**V+**|Switching voltage up to 55V,
117 +up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c)
119 119  |**2**|**NO**|Normally open contact
120 120  
121 121  === P7 – header of relay 4 ===
... ... @@ -127,7 +127,8 @@
127 127  By default, relay 4 is used to control the heater.
128 128  
129 129  |**Pin**|**Name**|**Description**
130 -|**1**|**V+**|Switching voltage (up to 55V, max 8A)
129 +|**1**|**V+**|Switching voltage up to 55V,
130 +up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c)
131 131  |**2**|**NO**|Normally open contact