Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -38,8 +38,6 @@ 38 38 39 39 === P1 – header for power supply === 40 40 41 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556 42 - 43 43 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 44 44 45 45 |**Pin**|**Name**|**Description** ... ... @@ -48,8 +48,6 @@ 48 48 49 49 === P15 – header for BMS Logic === 50 50 51 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030 52 - 53 53 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 54 54 55 55 |**Pin**|**Name**|**Description** ... ... @@ -60,8 +60,6 @@ 60 60 61 61 === P12 – header for current sensor === 62 62 63 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030 64 - 65 65 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 66 66 67 67 |**Pin**|**Name**|**Description** ... ... @@ -72,8 +72,6 @@ 72 72 73 73 === P13 – header for humidity sensor === 74 74 75 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030 76 - 77 77 [[image:1732198896526-660.png||data-xwiki-image-style-alignment="center" height="70" width="64"]] 78 78 79 79 |**Pin**|**Name**|**Description** ... ... @@ -84,8 +84,6 @@ 84 84 85 85 === P8 – header of relay 1 === 86 86 87 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556 88 - 89 89 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 90 90 91 91 By default, relay 1 is used to control the discharging contactor. ... ... @@ -96,8 +96,6 @@ 96 96 97 97 === P9 – header of relay 2 === 98 98 99 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556 100 - 101 101 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 102 102 103 103 By default, relay 2 is used to output the “Allow charging” signal. ... ... @@ -108,8 +108,6 @@ 108 108 109 109 === P6 – header of relay 3 === 110 110 111 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556 112 - 113 113 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 114 114 115 115 By default, relay 3 is used to control the charging contactor. ... ... @@ -120,8 +120,6 @@ 120 120 121 121 === P7 – header of relay 4 === 122 122 123 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556 124 - 125 125 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 126 126 127 127 By default, relay 4 is used to control the heater. ... ... @@ -132,8 +132,6 @@ 132 132 133 133 === P14 – header for CAN and RS-485 interfaces === 134 134 135 -Receptacle Housing: Molex 430250600. Terminals: Molex 43030 136 - 137 137 [[image:1731517180930-597.png||data-xwiki-image-style-alignment="center" height="81" width="113"]] 138 138 139 139 (% style="width:641px" %) ... ... @@ -167,8 +167,6 @@ 167 167 168 168 === P11 – header for discrete inputs/outputs === 169 169 170 -Receptacle Housing: Molex 430251600. Terminals: Molex 43030 171 - 172 172 [[image:1732198937514-731.png||data-xwiki-image-style-alignment="center" height="85" width="272"]] 173 173 174 174 |**Pin**|**Name**|**Description**