Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS Main 2\.1.WebHome1 +drafts.BMS Main 2\.1.WebHome - Content
-
... ... @@ -1,21 +1,15 @@ 1 -(% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Installation and connection = 1 +== 2.1 Installation procedure == 3 3 4 -== Installation procedure == 5 - 6 6 Overall and mounting dimensions of the BMS Main 2.1 are shown below. 7 7 8 8 [[image:1732198397369-222.png||data-xwiki-image-style-alignment="center" height="393" width="556"]] 9 9 10 -(% style="width:494px" %) 11 -|**Parameter**|(% style="width:178px" %)**Value** 12 -|Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 32 13 -|Mounting dimensions (length × width), mm|(% style="width:178px" %)114 × 114 14 -|Mounting holes|(% style="width:178px" %)M3 15 -|Headers P1, P6-P9 type |(% style="width:178px" %)Molex series Mini-Fit 16 -|Headers P11-P15 type |(% style="width:178px" %)Molex series Micro-Fit 7 +|**Parameter**|**Value** 8 +|Overall dimensions (length × width × height), mm|120 × 120 × 32 9 +|Mounting dimensions (length × width), mm|114 × 114 10 +|Mounting holes|M3 17 17 18 -== Connection procedure == 12 +== 2.2 Connection procedure == 19 19 20 20 The mounting area of the BMS Main 2.1 must be protected from mechanical particles (dust, dirt, large objects) and water. The installation site must provide convenient access for subsequent connection to the device’s headers. 21 21 ... ... @@ -24,7 +24,7 @@ 24 24 1. Connect the BMS Main 2.1 to the on-board CAN network. Observe the rules for connecting CAN devices. If the BMS Main 2.1 is the last device on a bus, close pins 1-2 on the P21 jumper, otherwise leave the jumper on pins 2-3. 25 25 1. Connect a power supply to the P1 header. It is not recommended to power the BMS Main 2.1 from the battery only, since at a critical discharge of the battery, it is not possible to turn on the BMS and close the charging contactor. 26 26 27 -== Headers description == 21 +== 2.3 Headers description == 28 28 29 29 The BMS Main 2.1 headers are shown in figure below. 30 30 ... ... @@ -36,10 +36,8 @@ 36 36 All headers are shown from the device side! 37 37 ))) 38 38 39 -=== P1 – header for power supply === 33 +=== 2.3.1 P1 – header for power supply === 40 40 41 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556 42 - 43 43 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 44 44 45 45 |**Pin**|**Name**|**Description** ... ... @@ -46,10 +46,8 @@ 46 46 |**1**|**GND**|Ground 47 47 |**2**|**V+**|Supply voltage 9-30V 48 48 49 -=== P15 – header for BMS Logic === 41 +=== 2.3.2 P15 – header for BMS Logic === 50 50 51 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030 52 - 53 53 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 54 54 55 55 |**Pin**|**Name**|**Description** ... ... @@ -58,10 +58,8 @@ 58 58 |**3**|**+5V**|Supply voltage for BMS Logic 59 59 |**4**|**GND**|Ground 60 60 61 -=== P12 – header for current sensor === 51 +=== 2.3.3 P12 – header for current sensor === 62 62 63 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030 64 - 65 65 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 66 66 67 67 |**Pin**|**Name**|**Description** ... ... @@ -70,10 +70,8 @@ 70 70 |**3**|**Vcs**|ADC input (current sensor output) 71 71 |**4**|**Vref**|ADC input (current sensor reference signal) 72 72 73 -=== P13 – header for humidity sensor === 61 +=== 2.3.4 P13 – header for humidity sensor === 74 74 75 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030 76 - 77 77 [[image:1732198896526-660.png||data-xwiki-image-style-alignment="center" height="70" width="64"]] 78 78 79 79 |**Pin**|**Name**|**Description** ... ... @@ -82,10 +82,8 @@ 82 82 |**3**|**Vhs**|ADC input (humidity sensor output) 83 83 |**4**|**Vts**|ADC input (temperature sensor output) 84 84 85 -=== P8 – header of relay 1 === 71 +=== 2.3.5 P8 – header of relay 1 === 86 86 87 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556 88 - 89 89 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 90 90 91 91 By default, relay 1 is used to control the discharging contactor. ... ... @@ -94,10 +94,8 @@ 94 94 |**1**|**V+**|Switching voltage (up to 55V, max 2A) 95 95 |**2**|**NO**|Normally open contact 96 96 97 -=== P9 – header of relay 2 === 81 +=== 2.3.6 P9 – header of relay 2 === 98 98 99 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556 100 - 101 101 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 102 102 103 103 By default, relay 2 is used to output the “Allow charging” signal. ... ... @@ -106,10 +106,8 @@ 106 106 |**1**|**V+**|Switching voltage (up to 55V, max 2A) 107 107 |**2**|**NO**|Normally open contact 108 108 109 -=== P6 – header of relay 3 === 91 +=== 2.3.7 P6 – header of relay 3 === 110 110 111 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556 112 - 113 113 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 114 114 115 115 By default, relay 3 is used to control the charging contactor. ... ... @@ -118,10 +118,8 @@ 118 118 |**1**|**V+**|Switching voltage (up to 55V, max 8A) 119 119 |**2**|**NO**|Normally open contact 120 120 121 -=== P7 – header of relay 4 === 101 +=== 2.3.8 P7 – header of relay 4 === 122 122 123 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556 124 - 125 125 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 126 126 127 127 By default, relay 4 is used to control the heater. ... ... @@ -130,10 +130,8 @@ 130 130 |**1**|**V+**|Switching voltage (up to 55V, max 8A) 131 131 |**2**|**NO**|Normally open contact 132 132 133 -=== P14 – header for CAN and RS-485 interfaces === 111 +=== 2.3.9 P14 – header for CAN and RS-485 interfaces === 134 134 135 -Receptacle Housing: Molex 430250600. Terminals: Molex 43030 136 - 137 137 [[image:1731517180930-597.png||data-xwiki-image-style-alignment="center" height="81" width="113"]] 138 138 139 139 (% style="width:641px" %) ... ... @@ -145,7 +145,7 @@ 145 145 |**5**|**CAN_L**|CAN L line for communication with external equipment 146 146 |**6**|**GND_CAN**|Ground 147 147 148 -=== P21 – CAN termination resistor jumper === 124 +=== 2.3.10 P21 – CAN termination resistor jumper === 149 149 150 150 [[image:1731517188900-976.png||data-xwiki-image-style-alignment="center" height="78" width="149"]] 151 151 ... ... @@ -155,7 +155,7 @@ 155 155 |**1-2**|**120 Ohm**|Termination resistor 120 Ohm is connected 156 156 |**2-3**|**-**|Termination resistor 120 Ohm is not connected 157 157 158 -=== P22 - RS-485 termination resistor jumper === 134 +=== 2.3.11 P22 - RS-485 termination resistor jumper === 159 159 160 160 [[image:1731517195672-298.png||data-xwiki-image-style-alignment="center" height="81" width="155"]] 161 161 ... ... @@ -165,10 +165,8 @@ 165 165 |**1-2**|**120 Ohm**|Terminating resistor 120 Ohm is connected 166 166 |**2-3**|**-**|Terminating resistor 120 Ohm is not connected 167 167 168 -=== P11 – header for discrete inputs/outputs === 144 +=== 2.3.12 P11 – header for discrete inputs/outputs === 169 169 170 -Receptacle Housing: Molex 430251600. Terminals: Molex 43030 171 - 172 172 [[image:1732198937514-731.png||data-xwiki-image-style-alignment="center" height="85" width="272"]] 173 173 174 174 |**Pin**|**Name**|**Description** ... ... @@ -189,51 +189,51 @@ 189 189 |**9**|**OUT_1**|Discrete output #1 (+5V, 20mA) 190 190 |**1**|**GND_OUT_1**|Discrete output #1 (ground) 191 191 192 -= =Indicators ==166 += 2.4 Indicators = 193 193 194 -=== DS1 – power indicator === 168 +=== 2.4.1 DS1 – power indicator === 195 195 196 196 |**State**|**Description** 197 197 |**Lights red**|The device is powered 198 198 |**Off**|The device is not powered 199 199 200 -=== DS2 – operation indicator === 174 +=== 2.4.2 DS2 – operation indicator === 201 201 202 202 |**State**|**Description** 203 203 |**Blinking green**|The BMS firmware is running 204 204 |**Off**|The BMS firmware is not running 205 205 206 -=== DS3 – communication indicator === 180 +=== 2.4.3 DS3 – communication indicator === 207 207 208 208 |**State**|**Description** 209 209 |**Blinking yellow (2Hz)**|Initializing communication with BMS Logic boards 210 210 |**Blinking yellow (25Hz)**|Communication with BMS Logic is established 211 211 212 -=== DS4 – error indicator === 186 +=== 2.4.4 DS4 – error indicator === 213 213 214 214 215 215 |(**State**|**Description** 216 216 |(**Blinking red**|Errors in communication with BMS Logic 217 217 218 -=== DS7 – relay 1 indicator === 192 +=== 2.4.5 DS7 – relay 1 indicator === 219 219 220 220 |**State**|**Description** 221 221 |**Lights green**|Relay #1 is closed 222 222 |**Off**|Relay #1 is opened 223 223 224 -=== DS8 – relay 2 indicator === 198 +=== 2.4.6 DS8 – relay 2 indicator === 225 225 226 226 |**State**|**Description** 227 227 |**Lights green**|Relay #2 is closed 228 228 |**Off**|Relay #2 is opened 229 229 230 -=== DS5 – relay 3 indicator === 204 +=== 2.4.7 DS5 – relay 3 indicator === 231 231 232 232 |**State**|**Description** 233 233 |**Lights green**|Relay #3 is closed 234 234 |**Off**|Relay #3 is opened 235 235 236 -=== DS6 – relay 4 indicator === 210 +=== 2.4.8 DS6 – relay 4 indicator === 237 237 238 238 |**State**|**Description** 239 239 |**Lights green**|Relay #4 is closed