Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -38,6 +38,8 @@ 38 38 39 39 === P1 – header for power supply === 40 40 41 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 42 + 41 41 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 42 42 43 43 |**Pin**|**Name**|**Description** ... ... @@ -46,6 +46,8 @@ 46 46 47 47 === P15 – header for BMS Logic === 48 48 51 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 52 + 49 49 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 50 50 51 51 |**Pin**|**Name**|**Description** ... ... @@ -56,6 +56,8 @@ 56 56 57 57 === P12 – header for current sensor === 58 58 63 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 64 + 59 59 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 60 60 61 61 |**Pin**|**Name**|**Description** ... ... @@ -66,6 +66,8 @@ 66 66 67 67 === P13 – header for humidity sensor === 68 68 75 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 76 + 69 69 [[image:1732198896526-660.png||data-xwiki-image-style-alignment="center" height="70" width="64"]] 70 70 71 71 |**Pin**|**Name**|**Description** ... ... @@ -76,6 +76,8 @@ 76 76 77 77 === P8 – header of relay 1 === 78 78 87 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 88 + 79 79 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 80 80 81 81 By default, relay 1 is used to control the discharging contactor. ... ... @@ -86,6 +86,8 @@ 86 86 87 87 === P9 – header of relay 2 === 88 88 99 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 100 + 89 89 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 90 90 91 91 By default, relay 2 is used to output the “Allow charging” signal. ... ... @@ -96,6 +96,8 @@ 96 96 97 97 === P6 – header of relay 3 === 98 98 111 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 112 + 99 99 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 100 100 101 101 By default, relay 3 is used to control the charging contactor. ... ... @@ -106,6 +106,8 @@ 106 106 107 107 === P7 – header of relay 4 === 108 108 123 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 124 + 109 109 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 110 110 111 111 By default, relay 4 is used to control the heater. ... ... @@ -116,6 +116,8 @@ 116 116 117 117 === P14 – header for CAN and RS-485 interfaces === 118 118 135 +Receptacle Housing: Molex 430250600. Terminals: Molex 43030 136 + 119 119 [[image:1731517180930-597.png||data-xwiki-image-style-alignment="center" height="81" width="113"]] 120 120 121 121 (% style="width:641px" %) ... ... @@ -149,6 +149,8 @@ 149 149 150 150 === P11 – header for discrete inputs/outputs === 151 151 170 +Receptacle Housing: Molex 430251600. Terminals: Molex 43030 171 + 152 152 [[image:1732198937514-731.png||data-xwiki-image-style-alignment="center" height="85" width="272"]] 153 153 154 154 |**Pin**|**Name**|**Description**