Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS Main 2\.1.WebHome1 +drafts.BMS Main 2\.1.WebHome - Content
-
... ... @@ -1,21 +1,15 @@ 1 -(% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Installation and connection = 1 +== 2.1 Installation procedure == 3 3 4 -== Installation procedure == 5 - 6 6 Overall and mounting dimensions of the BMS Main 2.1 are shown below. 7 7 8 8 [[image:1732198397369-222.png||data-xwiki-image-style-alignment="center" height="393" width="556"]] 9 9 10 -(% style="width:494px" %) 11 -|**Parameter**|(% style="width:178px" %)**Value** 12 -|Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 32 13 -|Mounting dimensions (length × width), mm|(% style="width:178px" %)114 × 114 14 -|Mounting holes|(% style="width:178px" %)M3 15 -|Headers P1, P6-P9 type |(% style="width:178px" %)Molex series Mini-Fit 16 -|Headers P11-P15 type |(% style="width:178px" %)Molex series Micro-Fit 7 +|**Parameter**|**Value** 8 +|Overall dimensions (length × width × height), mm|120 × 120 × 32 9 +|Mounting dimensions (length × width), mm|114 × 114 10 +|Mounting holes|M3 17 17 18 -== Connection procedure == 12 +== 2.2 Connection procedure == 19 19 20 20 The mounting area of the BMS Main 2.1 must be protected from mechanical particles (dust, dirt, large objects) and water. The installation site must provide convenient access for subsequent connection to the device’s headers. 21 21 ... ... @@ -24,7 +24,7 @@ 24 24 1. Connect the BMS Main 2.1 to the on-board CAN network. Observe the rules for connecting CAN devices. If the BMS Main 2.1 is the last device on a bus, close pins 1-2 on the P21 jumper, otherwise leave the jumper on pins 2-3. 25 25 1. Connect a power supply to the P1 header. It is not recommended to power the BMS Main 2.1 from the battery only, since at a critical discharge of the battery, it is not possible to turn on the BMS and close the charging contactor. 26 26 27 -== Headers description == 21 +== 2.3 Headers description == 28 28 29 29 The BMS Main 2.1 headers are shown in figure below. 30 30 ... ... @@ -36,7 +36,7 @@ 36 36 All headers are shown from the device side! 37 37 ))) 38 38 39 -=== P1 – header for power supply === 33 +=== 2.3.1 P1 – header for power supply === 40 40 41 41 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 42 42 ... ... @@ -44,7 +44,7 @@ 44 44 |**1**|**GND**|Ground 45 45 |**2**|**V+**|Supply voltage 9-30V 46 46 47 -=== P15 – header for BMS Logic === 41 +=== 2.3.2 P15 – header for BMS Logic === 48 48 49 49 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 50 50 ... ... @@ -54,7 +54,7 @@ 54 54 |**3**|**+5V**|Supply voltage for BMS Logic 55 55 |**4**|**GND**|Ground 56 56 57 -=== P12 – header for current sensor === 51 +=== 2.3.3 P12 – header for current sensor === 58 58 59 59 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 60 60 ... ... @@ -64,7 +64,7 @@ 64 64 |**3**|**Vcs**|ADC input (current sensor output) 65 65 |**4**|**Vref**|ADC input (current sensor reference signal) 66 66 67 -=== P13 – header for humidity sensor === 61 +=== 2.3.4 P13 – header for humidity sensor === 68 68 69 69 [[image:1732198896526-660.png||data-xwiki-image-style-alignment="center" height="70" width="64"]] 70 70 ... ... @@ -74,7 +74,7 @@ 74 74 |**3**|**Vhs**|ADC input (humidity sensor output) 75 75 |**4**|**Vts**|ADC input (temperature sensor output) 76 76 77 -=== P8 – header of relay 1 === 71 +=== 2.3.5 P8 – header of relay 1 === 78 78 79 79 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 80 80 ... ... @@ -84,7 +84,7 @@ 84 84 |**1**|**V+**|Switching voltage (up to 55V, max 2A) 85 85 |**2**|**NO**|Normally open contact 86 86 87 -=== P9 – header of relay 2 === 81 +=== 2.3.6 P9 – header of relay 2 === 88 88 89 89 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 90 90 ... ... @@ -94,7 +94,7 @@ 94 94 |**1**|**V+**|Switching voltage (up to 55V, max 2A) 95 95 |**2**|**NO**|Normally open contact 96 96 97 -=== P6 – header of relay 3 === 91 +=== 2.3.7 P6 – header of relay 3 === 98 98 99 99 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 100 100 ... ... @@ -104,7 +104,7 @@ 104 104 |**1**|**V+**|Switching voltage (up to 55V, max 8A) 105 105 |**2**|**NO**|Normally open contact 106 106 107 -=== P7 – header of relay 4 === 101 +=== 2.3.8 P7 – header of relay 4 === 108 108 109 109 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 110 110 ... ... @@ -114,7 +114,7 @@ 114 114 |**1**|**V+**|Switching voltage (up to 55V, max 8A) 115 115 |**2**|**NO**|Normally open contact 116 116 117 -=== P14 – header for CAN and RS-485 interfaces === 111 +=== 2.3.9 P14 – header for CAN and RS-485 interfaces === 118 118 119 119 [[image:1731517180930-597.png||data-xwiki-image-style-alignment="center" height="81" width="113"]] 120 120 ... ... @@ -127,7 +127,7 @@ 127 127 |**5**|**CAN_L**|CAN L line for communication with external equipment 128 128 |**6**|**GND_CAN**|Ground 129 129 130 -=== P21 – CAN termination resistor jumper === 124 +=== 2.3.10 P21 – CAN termination resistor jumper === 131 131 132 132 [[image:1731517188900-976.png||data-xwiki-image-style-alignment="center" height="78" width="149"]] 133 133 ... ... @@ -137,7 +137,7 @@ 137 137 |**1-2**|**120 Ohm**|Termination resistor 120 Ohm is connected 138 138 |**2-3**|**-**|Termination resistor 120 Ohm is not connected 139 139 140 -=== P22 - RS-485 termination resistor jumper === 134 +=== 2.3.11 P22 - RS-485 termination resistor jumper === 141 141 142 142 [[image:1731517195672-298.png||data-xwiki-image-style-alignment="center" height="81" width="155"]] 143 143 ... ... @@ -147,7 +147,7 @@ 147 147 |**1-2**|**120 Ohm**|Terminating resistor 120 Ohm is connected 148 148 |**2-3**|**-**|Terminating resistor 120 Ohm is not connected 149 149 150 -=== P11 – header for discrete inputs/outputs === 144 +=== 2.3.12 P11 – header for discrete inputs/outputs === 151 151 152 152 [[image:1732198937514-731.png||data-xwiki-image-style-alignment="center" height="85" width="272"]] 153 153 ... ... @@ -169,51 +169,51 @@ 169 169 |**9**|**OUT_1**|Discrete output #1 (+5V, 20mA) 170 170 |**1**|**GND_OUT_1**|Discrete output #1 (ground) 171 171 172 -= =Indicators ==166 += 2.4 Indicators = 173 173 174 -=== DS1 – power indicator === 168 +=== 2.4.1 DS1 – power indicator === 175 175 176 176 |**State**|**Description** 177 177 |**Lights red**|The device is powered 178 178 |**Off**|The device is not powered 179 179 180 -=== DS2 – operation indicator === 174 +=== 2.4.2 DS2 – operation indicator === 181 181 182 182 |**State**|**Description** 183 183 |**Blinking green**|The BMS firmware is running 184 184 |**Off**|The BMS firmware is not running 185 185 186 -=== DS3 – communication indicator === 180 +=== 2.4.3 DS3 – communication indicator === 187 187 188 188 |**State**|**Description** 189 189 |**Blinking yellow (2Hz)**|Initializing communication with BMS Logic boards 190 190 |**Blinking yellow (25Hz)**|Communication with BMS Logic is established 191 191 192 -=== DS4 – error indicator === 186 +=== 2.4.4 DS4 – error indicator === 193 193 194 194 195 195 |(**State**|**Description** 196 196 |(**Blinking red**|Errors in communication with BMS Logic 197 197 198 -=== DS7 – relay 1 indicator === 192 +=== 2.4.5 DS7 – relay 1 indicator === 199 199 200 200 |**State**|**Description** 201 201 |**Lights green**|Relay #1 is closed 202 202 |**Off**|Relay #1 is opened 203 203 204 -=== DS8 – relay 2 indicator === 198 +=== 2.4.6 DS8 – relay 2 indicator === 205 205 206 206 |**State**|**Description** 207 207 |**Lights green**|Relay #2 is closed 208 208 |**Off**|Relay #2 is opened 209 209 210 -=== DS5 – relay 3 indicator === 204 +=== 2.4.7 DS5 – relay 3 indicator === 211 211 212 212 |**State**|**Description** 213 213 |**Lights green**|Relay #3 is closed 214 214 |**Off**|Relay #3 is opened 215 215 216 -=== DS6 – relay 4 indicator === 210 +=== 2.4.8 DS6 – relay 4 indicator === 217 217 218 218 |**State**|**Description** 219 219 |**Lights green**|Relay #4 is closed