Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,7 +12,6 @@ 12 12 |Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 32 13 13 |Mounting dimensions (length × width), mm|(% style="width:178px" %)114 × 114 14 14 |Mounting holes|(% style="width:178px" %)M3 15 -|Connectors type|(% style="width:178px" %)Molex MiniFit (P1, P6) 16 16 17 17 == Connection procedure == 18 18 ... ... @@ -37,6 +37,8 @@ 37 37 38 38 === P1 – header for power supply === 39 39 39 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 40 + 40 40 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 41 41 42 42 |**Pin**|**Name**|**Description** ... ... @@ -45,6 +45,8 @@ 45 45 46 46 === P15 – header for BMS Logic === 47 47 49 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 50 + 48 48 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 49 49 50 50 |**Pin**|**Name**|**Description** ... ... @@ -55,6 +55,8 @@ 55 55 56 56 === P12 – header for current sensor === 57 57 61 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 62 + 58 58 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 59 59 60 60 |**Pin**|**Name**|**Description** ... ... @@ -65,6 +65,8 @@ 65 65 66 66 === P13 – header for humidity sensor === 67 67 73 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 74 + 68 68 [[image:1732198896526-660.png||data-xwiki-image-style-alignment="center" height="70" width="64"]] 69 69 70 70 |**Pin**|**Name**|**Description** ... ... @@ -75,6 +75,8 @@ 75 75 76 76 === P8 – header of relay 1 === 77 77 85 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 86 + 78 78 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 79 79 80 80 By default, relay 1 is used to control the discharging contactor. ... ... @@ -85,6 +85,8 @@ 85 85 86 86 === P9 – header of relay 2 === 87 87 97 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 98 + 88 88 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 89 89 90 90 By default, relay 2 is used to output the “Allow charging” signal. ... ... @@ -95,6 +95,8 @@ 95 95 96 96 === P6 – header of relay 3 === 97 97 109 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 110 + 98 98 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 99 99 100 100 By default, relay 3 is used to control the charging contactor. ... ... @@ -105,6 +105,8 @@ 105 105 106 106 === P7 – header of relay 4 === 107 107 121 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 122 + 108 108 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 109 109 110 110 By default, relay 4 is used to control the heater. ... ... @@ -115,6 +115,8 @@ 115 115 116 116 === P14 – header for CAN and RS-485 interfaces === 117 117 133 +Receptacle Housing: Molex 430250600. Terminals: Molex 43030 134 + 118 118 [[image:1731517180930-597.png||data-xwiki-image-style-alignment="center" height="81" width="113"]] 119 119 120 120 (% style="width:641px" %) ... ... @@ -148,6 +148,8 @@ 148 148 149 149 === P11 – header for discrete inputs/outputs === 150 150 168 +Receptacle Housing: Molex 430251600. Terminals: Molex 43030 169 + 151 151 [[image:1732198937514-731.png||data-xwiki-image-style-alignment="center" height="85" width="272"]] 152 152 153 153 |**Pin**|**Name**|**Description**