Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,22 @@ 1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Installation and connection = 3 3 4 +== Safety rules == 5 + 6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS. 7 + 8 +Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured. 9 + 10 +(% class="box warningmessage" %) 11 +((( 12 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 13 +))) 14 + 15 +(% class="box errormessage" %) 16 +((( 17 +**The system is not designed to operate with batteries whose total voltage exceeds 1200 V.** 18 +))) 19 + 4 4 == Installation procedure == 5 5 6 6 Overall and mounting dimensions of the BMS Main 2.1 are shown below. ... ... @@ -7,10 +7,11 @@ 7 7 8 8 [[image:1732198397369-222.png||data-xwiki-image-style-alignment="center" height="393" width="556"]] 9 9 10 -|**Parameter**|**Value** 11 -|Overall dimensions (length × width × height), mm|120 × 120 × 32 12 -|Mounting dimensions (length × width), mm|114 × 114 13 -|Mounting holes|M3 26 +(% style="width:494px" %) 27 +|**Parameter**|(% style="width:178px" %)**Value** 28 +|Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 32 29 +|Mounting dimensions (length × width), mm|(% style="width:178px" %)114 × 114 30 +|Mounting holes|(% style="width:178px" %)M3 14 14 15 15 == Connection procedure == 16 16 ... ... @@ -35,6 +35,8 @@ 35 35 36 36 === P1 – header for power supply === 37 37 55 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 56 + 38 38 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 39 39 40 40 |**Pin**|**Name**|**Description** ... ... @@ -43,6 +43,8 @@ 43 43 44 44 === P15 – header for BMS Logic === 45 45 65 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 66 + 46 46 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 47 47 48 48 |**Pin**|**Name**|**Description** ... ... @@ -53,6 +53,8 @@ 53 53 54 54 === P12 – header for current sensor === 55 55 77 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 78 + 56 56 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 57 57 58 58 |**Pin**|**Name**|**Description** ... ... @@ -63,6 +63,8 @@ 63 63 64 64 === P13 – header for humidity sensor === 65 65 89 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 90 + 66 66 [[image:1732198896526-660.png||data-xwiki-image-style-alignment="center" height="70" width="64"]] 67 67 68 68 |**Pin**|**Name**|**Description** ... ... @@ -73,46 +73,68 @@ 73 73 74 74 === P8 – header of relay 1 === 75 75 101 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 102 + 76 76 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 77 77 78 78 By default, relay 1 is used to control the discharging contactor. 79 79 80 80 |**Pin**|**Name**|**Description** 81 -|**1**|**V+**|Switching voltage (up to 55V, max 2A)108 +|**1**|**V+**|Switching voltage (up to 55V, max 3A) 82 82 |**2**|**NO**|Normally open contact 83 83 111 +Contactor connection example for all relays: 112 + 113 +[[image:1741619814065-850.png||height="189" width="252"]] 114 + 84 84 === P9 – header of relay 2 === 85 85 117 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 118 + 86 86 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 87 87 88 88 By default, relay 2 is used to output the “Allow charging” signal. 89 89 90 90 |**Pin**|**Name**|**Description** 91 -|**1**|**V+**|Switching voltage (up to 55V, max 2A)124 +|**1**|**V+**|Switching voltage (up to 55V, max 3A) 92 92 |**2**|**NO**|Normally open contact 93 93 127 +Contactor connection example: see relay 1. 128 + 94 94 === P6 – header of relay 3 === 95 95 131 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 132 + 96 96 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 97 97 98 98 By default, relay 3 is used to control the charging contactor. 99 99 100 100 |**Pin**|**Name**|**Description** 101 -|**1**|**V+**|Switching voltage (up to 55V, max 8A) 138 +|**1**|**V+**|Switching voltage up to 55V, 139 +up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 102 102 |**2**|**NO**|Normally open contact 103 103 142 +Contactor connection example: see relay 1. 143 + 104 104 === P7 – header of relay 4 === 105 105 146 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 147 + 106 106 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 107 107 108 108 By default, relay 4 is used to control the heater. 109 109 110 110 |**Pin**|**Name**|**Description** 111 -|**1**|**V+**|Switching voltage (up to 55V, max 8A) 153 +|**1**|**V+**|Switching voltage up to 55V, 154 +up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 112 112 |**2**|**NO**|Normally open contact 113 113 157 +Contactor connection example: see relay 1. 158 + 114 114 === P14 – header for CAN and RS-485 interfaces === 115 115 161 +Receptacle Housing: Molex 430250600. Terminals: Molex 43030 162 + 116 116 [[image:1731517180930-597.png||data-xwiki-image-style-alignment="center" height="81" width="113"]] 117 117 118 118 (% style="width:641px" %) ... ... @@ -146,6 +146,8 @@ 146 146 147 147 === P11 – header for discrete inputs/outputs === 148 148 196 +Receptacle Housing: Molex 430251600. Terminals: Molex 43030 197 + 149 149 [[image:1732198937514-731.png||data-xwiki-image-style-alignment="center" height="85" width="272"]] 150 150 151 151 |**Pin**|**Name**|**Description**
- 1741619628288-759.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.2 KB - Content
- 1741619637854-961.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.2 KB - Content
- 1741619700532-367.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.1 KB - Content
- 1741619814065-850.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.1 KB - Content
- 1741620022836-867.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.3 KB - Content