Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -5,7 +5,9 @@ 5 5 [[image:1732198397369-222.png||data-xwiki-image-style-alignment="center" height="393" width="556"]] 6 6 7 7 |**Parameter**|**Value** 8 -|Overall dimensions (length × width × height), mm|120 × 120 × 32 8 +|((( 9 +Overall dimensions (length × width × height), mm 10 +)))|120 × 120 × 32 9 9 |Mounting dimensions (length × width), mm|114 × 114 10 10 |Mounting holes|M3 11 11 ... ... @@ -31,39 +31,44 @@ 31 31 32 32 [[image:1732198827034-560.png||height="78" width="41"]] 33 33 34 -|**Pin**|**Name**|**Description** 35 -|**1**|**GND**|Ground 36 -|**2**|**V+**|Supply voltage 9-30V 36 +(% style="width:339px" %) 37 +|(% style="width:71px" %)**Pin**|(% style="width:91px" %)**Name**|(% style="width:174px" %)**Description** 38 +|(% style="width:71px" %)**1**|(% style="width:91px" %)**GND**|(% style="width:174px" %)Ground 39 +|(% style="width:71px" %)**2**|(% style="width:91px" %)**V+**|(% style="width:174px" %)Supply voltage 9-30V 37 37 38 38 === 2.3.2 P15 – header for BMS Logic === 39 39 40 40 [[image:1732198890482-787.png||height="77" width="71"]] 41 41 42 -|**Pin**|**Name**|**Description** 43 -|**1**|**RS485_A**|RS-485 line A for communication with BMS Logic 44 -|**2**|**RS485_B**|RS-485 line B for communication with BMS Logic 45 -|**3**|**+5V**|Supply voltage for BMS Logic 46 -|**4**|**GND**|Ground 47 47 46 +(% style="width:524px" %) 47 +|(% style="width:69px" %)**Pin**|(% style="width:97px" %)**Name**|(% style="width:355px" %)**Description** 48 +|(% style="width:69px" %)**1**|(% style="width:97px" %)**RS485_A**|(% style="width:355px" %)RS-485 line A for communication with BMS Logic 49 +|(% style="width:69px" %)**2**|(% style="width:97px" %)**RS485_B**|(% style="width:355px" %)RS-485 line B for communication with BMS Logic 50 +|(% style="width:69px" %)**3**|(% style="width:97px" %)**+5V**|(% style="width:355px" %)Supply voltage for BMS Logic 51 +|(% style="width:69px" %)**4**|(% style="width:97px" %)**GND**|(% style="width:355px" %)Ground 52 + 48 48 === 2.3.3 P12 – header for current sensor === 49 49 50 50 [[image:1732198890482-787.png||height="77" width="71"]] 51 51 52 -|**Pin**|**Name**|**Description** 53 -|**1**|**+5V**|Supply voltage for the current sensor 5V, max 50 mA 54 -|**2**|**GND**|Ground 55 -|**3**|**Vcs**|ADC input (current sensor output) 56 -|**4**|**Vref**|ADC input (current sensor reference signal) 57 +(% style="width:531px" %) 58 +|(% style="width:75px" %)**Pin**|(% style="width:93px" %)**Name**|(% style="width:360px" %)**Description** 59 +|(% style="width:75px" %)**1**|(% style="width:93px" %)**+5V**|(% style="width:360px" %)Supply voltage for the current sensor 5V, max 50 mA 60 +|(% style="width:75px" %)**2**|(% style="width:93px" %)**GND**|(% style="width:360px" %)Ground 61 +|(% style="width:75px" %)**3**|(% style="width:93px" %)**Vcs**|(% style="width:360px" %)ADC input (current sensor output) 62 +|(% style="width:75px" %)**4**|(% style="width:93px" %)**Vref**|(% style="width:360px" %)ADC input (current sensor reference signal) 57 57 58 58 === 2.3.4 P13 – header for humidity sensor === 59 59 60 60 [[image:1732198896526-660.png||height="70" width="64"]] 61 61 62 -|**Pin**|**Name**|**Description** 63 -|**1**|**+5V**|Supply voltage 5 V, max 50 mA 64 -|**2**|**GND**|Ground 65 -|**3**|**Vhs**|ADC input (humidity sensor output) 66 -|**4**|**Vts**|ADC input (temperature sensor output) 68 +(% style="width:531px" %) 69 +|(% style="width:77px" %)**Pin**|(% style="width:92px" %)**Name**|(% style="width:359px" %)**Description** 70 +|(% style="width:77px" %)**1**|(% style="width:92px" %)**+5V**|(% style="width:359px" %)Supply voltage 5 V, max 50 mA 71 +|(% style="width:77px" %)**2**|(% style="width:92px" %)**GND**|(% style="width:359px" %)Ground 72 +|(% style="width:77px" %)**3**|(% style="width:92px" %)**Vhs**|(% style="width:359px" %)ADC input (humidity sensor output) 73 +|(% style="width:77px" %)**4**|(% style="width:92px" %)**Vts**|(% style="width:359px" %)ADC input (temperature sensor output) 67 67 68 68 === 2.3.5 P8 – header of relay 1 === 69 69 ... ... @@ -71,9 +71,10 @@ 71 71 72 72 By default, relay 1 is used to control the discharging contactor. 73 73 74 -|**Pin**|**Name**|**Description** 75 -|**1**|**V+**|Switching voltage (up to 55V, max 2A) 76 -|**2**|**NO**|Normally open contact 81 +(% style="width:527px" %) 82 +|(% style="width:82px" %)**Pin**|(% style="width:91px" %)**Name**|(% style="width:351px" %)**Description** 83 +|(% style="width:82px" %)**1**|(% style="width:91px" %)**V+**|(% style="width:351px" %)Switching voltage (up to 55V, max 2A) 84 +|(% style="width:82px" %)**2**|(% style="width:91px" %)**NO**|(% style="width:351px" %)Normally open contact 77 77 78 78 === 2.3.6 P9 – header of relay 2 === 79 79 ... ... @@ -81,9 +81,10 @@ 81 81 82 82 By default, relay 2 is used to output the “Allow charging” signal. 83 83 84 -|**Pin**|**Name**|**Description** 85 -|**1**|**V+**|Switching voltage (up to 55V, max 2A) 86 -|**2**|**NO**|Normally open contact 92 +(% style="width:524px" %) 93 +|(% style="width:89px" %)**Pin**|(% style="width:91px" %)**Name**|(% style="width:341px" %)**Description** 94 +|(% style="width:89px" %)**1**|(% style="width:91px" %)**V+**|(% style="width:341px" %)Switching voltage (up to 55V, max 2A) 95 +|(% style="width:89px" %)**2**|(% style="width:91px" %)**NO**|(% style="width:341px" %)Normally open contact 87 87 88 88 === 2.3.7 P6 – header of relay 3 === 89 89 ... ... @@ -91,9 +91,10 @@ 91 91 92 92 By default, relay 3 is used to control the charging contactor. 93 93 94 -|**Pin**|**Name**|**Description** 95 -|**1**|**V+**|Switching voltage (up to 55V, max 8A) 96 -|**2**|**NO**|Normally open contact 103 +(% style="width:524px" %) 104 +|(% style="width:101px" %)**Pin**|(% style="width:88px" %)**Name**|(% style="width:332px" %)**Description** 105 +|(% style="width:101px" %)**1**|(% style="width:88px" %)**V+**|(% style="width:332px" %)Switching voltage (up to 55V, max 8A) 106 +|(% style="width:101px" %)**2**|(% style="width:88px" %)**NO**|(% style="width:332px" %)Normally open contact 97 97 98 98 === 2.3.8 P7 – header of relay 4 === 99 99 ... ... @@ -101,9 +101,10 @@ 101 101 102 102 By default, relay 4 is used to control the heater. 103 103 104 -|**Pin**|**Name**|**Description** 105 -|**1**|**V+**|Switching voltage (up to 55V, max 8A) 106 -|**2**|**NO**|Normally open contact 114 +(% style="width:530px" %) 115 +|(% style="width:102px" %)**Pin**|(% style="width:93px" %)**Name**|(% style="width:332px" %)**Description** 116 +|(% style="width:102px" %)**1**|(% style="width:93px" %)**V+**|(% style="width:332px" %)Switching voltage (up to 55V, max 8A) 117 +|(% style="width:102px" %)**2**|(% style="width:93px" %)**NO**|(% style="width:332px" %)Normally open contact 107 107 108 108 === 2.3.9 P14 – header for CAN and RS-485 interfaces === 109 109 ... ... @@ -110,13 +110,13 @@ 110 110 [[image:1731517180930-597.png||height="81" width="113"]] 111 111 112 112 (% style="width:641px" %) 113 -|**Pin**|**Name**|**Description** 114 -|**1**|**EXT_RS485_A**|RS-485 line A for communication with external equipment 115 -|**2**|**CAN_H**|CAN H line for communication with external equipment 116 -|**3**|**+5V_CAN**|Supply voltage 5V for external devices, max 200 mA 117 -|**4**|**EXT_RS485_B**|RS-485 line B for communication with external equipment 118 -|**5**|**CAN_L**|CAN L line for communication with external equipment 119 -|**6**|**GND_CAN**|Ground 124 +|(% style="width:107px" %)**Pin**|(% style="width:127px" %)**Name**|(% style="width:404px" %)**Description** 125 +|(% style="width:107px" %)**1**|(% style="width:127px" %)**EXT_RS485_A**|(% style="width:404px" %)RS-485 line A for communication with external equipment 126 +|(% style="width:107px" %)**2**|(% style="width:127px" %)**CAN_H**|(% style="width:404px" %)CAN H line for communication with external equipment 127 +|(% style="width:107px" %)**3**|(% style="width:127px" %)**+5V_CAN**|(% style="width:404px" %)Supply voltage 5V for external devices, max 200 mA 128 +|(% style="width:107px" %)**4**|(% style="width:127px" %)**EXT_RS485_B**|(% style="width:404px" %)RS-485 line B for communication with external equipment 129 +|(% style="width:107px" %)**5**|(% style="width:127px" %)**CAN_L**|(% style="width:404px" %)CAN L line for communication with external equipment 130 +|(% style="width:107px" %)**6**|(% style="width:127px" %)**GND_CAN**|(% style="width:404px" %)Ground 120 120 121 121 === 2.3.10 P21 – CAN termination resistor jumper === 122 122 ... ... @@ -124,9 +124,10 @@ 124 124 125 125 To connect the termination resistor between the lines **CAN_H** and **CAN_L**, install a jumper, according to the P21 pinout: 126 126 127 -|**Pin**|**Name**|**Description** 128 -|**1-2**|**120 Ohm**|Termination resistor 120 Ohm is connected 129 -|**2-3**|**-**|Termination resistor 120 Ohm is not connected 138 +(% style="width:643px" %) 139 +|**Pin**|(% style="width:122px" %)**Name**|(% style="width:400px" %)**Description** 140 +|**1-2**|(% style="width:122px" %)**120 Ohm**|(% style="width:400px" %)Termination resistor 120 Ohm is connected 141 +|**2-3**|(% style="width:122px" %)**-**|(% style="width:400px" %)Termination resistor 120 Ohm is not connected 130 130 131 131 === 2.3.11 P22 - RS-485 termination resistor jumper === 132 132 ... ... @@ -134,80 +134,89 @@ 134 134 135 135 To connect the termination resistor between the **EXT_RS485_A** and **EXT_RS485_B** lines, install a jumper according to the P22 pinout: 136 136 137 -|**Pin**|**Name**|**Description** 138 -|**1-2**|**120 Ohm**|Terminating resistor 120 Ohm is connected 139 -|**2-3**|**-**|Terminating resistor 120 Ohm is not connected 149 +(% style="width:644px" %) 150 +|**Pin**|(% style="width:121px" %)**Name**|(% style="width:402px" %)**Description** 151 +|**1-2**|(% style="width:121px" %)**120 Ohm**|(% style="width:402px" %)Terminating resistor 120 Ohm is connected 152 +|**2-3**|(% style="width:121px" %)**-**|(% style="width:402px" %)Terminating resistor 120 Ohm is not connected 140 140 141 141 === 2.3.12 P11 – header for discrete inputs/outputs === 142 142 143 143 [[image:1732198937514-731.png||height="85" width="272"]] 144 144 145 -|**Pin**|**Name**|**Description** 146 -|**16**|**IN_1**|Discrete input #1 “dry contact” (+5V) 147 -|**8**|**GND_1**|Discrete input #1 “dry contact” (ground) 148 -|**15**|**IN_2**|Discrete input #2 “dry contact” (+5V) 149 -|**7**|**GND_2**|Discrete input #2 “dry contact” (ground) 150 -|**14**|**IN_3**|Discrete input #3 “dry contact” (+5V) 151 -|**6**|**GND_3**|Discrete input #3 “dry contact” (ground) 152 -|**13**|**IN_4**|Discrete input #4 “dry contact” (+5V) 153 -|**5**|**GND_4**|Discrete input #4 “dry contact” (ground) 154 -|**12**|**OUT_4**|Discrete output #4 (+5V, 20mA) 155 -|**4**|**GND_OUT_4**|Discrete output #4 (ground) 156 -|**11**|**OUT_3**|Discrete output #3 (+5V, 20mA) 157 -|**3**|**GND_OUT_3**|Discrete output #3 (ground) 158 -|**10**|**OUT_2**|Discrete output #2 (+5V, 20mA) 159 -|**2**|**GND_OUT_2**|Discrete output #2 (ground) 160 -|**9**|**OUT_1**|Discrete output #1 (+5V, 20mA) 161 -|**1**|**GND_OUT_1**|Discrete output #1 (ground) 158 +(% style="width:584px" %) 159 +|(% style="width:98px" %)**Pin**|(% style="width:157px" %)**Name**|(% style="width:326px" %)**Description** 160 +|(% style="width:98px" %)**16**|(% style="width:157px" %)**IN_1**|(% style="width:326px" %)Discrete input #1 “dry contact” (+5V) 161 +|(% style="width:98px" %)**8**|(% style="width:157px" %)**GND_1**|(% style="width:326px" %)Discrete input #1 “dry contact” (ground) 162 +|(% style="width:98px" %)**15**|(% style="width:157px" %)**IN_2**|(% style="width:326px" %)Discrete input #2 “dry contact” (+5V) 163 +|(% style="width:98px" %)**7**|(% style="width:157px" %)**GND_2**|(% style="width:326px" %)Discrete input #2 “dry contact” (ground) 164 +|(% style="width:98px" %)**14**|(% style="width:157px" %)**IN_3**|(% style="width:326px" %)Discrete input #3 “dry contact” (+5V) 165 +|(% style="width:98px" %)**6**|(% style="width:157px" %)**GND_3**|(% style="width:326px" %)Discrete input #3 “dry contact” (ground) 166 +|(% style="width:98px" %)**13**|(% style="width:157px" %)**IN_4**|(% style="width:326px" %)Discrete input #4 “dry contact” (+5V) 167 +|(% style="width:98px" %)**5**|(% style="width:157px" %)**GND_4**|(% style="width:326px" %)Discrete input #4 “dry contact” (ground) 168 +|(% style="width:98px" %)**12**|(% style="width:157px" %)**OUT_4**|(% style="width:326px" %)Discrete output #4 (+5V, 20mA) 169 +|(% style="width:98px" %)**4**|(% style="width:157px" %)**GND_OUT_4**|(% style="width:326px" %)Discrete output #4 (ground) 170 +|(% style="width:98px" %)**11**|(% style="width:157px" %)**OUT_3**|(% style="width:326px" %)Discrete output #3 (+5V, 20mA) 171 +|(% style="width:98px" %)**3**|(% style="width:157px" %)**GND_OUT_3**|(% style="width:326px" %)Discrete output #3 (ground) 172 +|(% style="width:98px" %)**10**|(% style="width:157px" %)**OUT_2**|(% style="width:326px" %)Discrete output #2 (+5V, 20mA) 173 +|(% style="width:98px" %)**2**|(% style="width:157px" %)**GND_OUT_2**|(% style="width:326px" %)Discrete output #2 (ground) 174 +|(% style="width:98px" %)**9**|(% style="width:157px" %)**OUT_1**|(% style="width:326px" %)Discrete output #1 (+5V, 20mA) 175 +|(% style="width:98px" %)**1**|(% style="width:157px" %)**GND_OUT_1**|(% style="width:326px" %)Discrete output #1 (ground) 162 162 163 163 = 2.4 Indicators = 164 164 165 165 === 2.4.1 DS1 – power indicator === 166 166 167 -|**State**|**Description** 168 -|**Lights red**|The device is powered 169 -|**Off**|The device is not powered 181 +(% style="width:442px" %) 182 +|(% style="width:138px" %)**State**|(% style="width:301px" %)**Description** 183 +|(% style="width:138px" %)**Lights red**|(% style="width:301px" %)The device is powered 184 +|(% style="width:138px" %)**Off**|(% style="width:301px" %)The device is not powered 170 170 171 171 === 2.4.2 DS2 – operation indicator === 172 172 173 -|**State**|**Description** 174 -|**Blinking green**|The BMS firmware is running 175 -|**Off**|The BMS firmware is not running 188 +(% style="width:442px" %) 189 +|(% style="width:137px" %)**State**|(% style="width:302px" %)**Description** 190 +|(% style="width:137px" %)**Blinking green**|(% style="width:302px" %)The BMS firmware is running 191 +|(% style="width:137px" %)**Off**|(% style="width:302px" %)The BMS firmware is not running 176 176 177 177 === 2.4.3 DS3 – communication indicator === 178 178 179 -|**State**|**Description** 180 -|**Blinking yellow (2Hz)**|Initializing communication with BMS Logic boards 181 -|**Blinking yellow (25Hz)**|Communication with BMS Logic is established 195 +(% style="width:539px" %) 196 +|(% style="width:175px" %)**State**|(% style="width:361px" %)**Description** 197 +|(% style="width:175px" %)**Blinking yellow (2Hz)**|(% style="width:361px" %)Initializing communication with BMS Logic boards 198 +|(% style="width:175px" %)**Blinking yellow (25Hz)**|(% style="width:361px" %)Communication with BMS Logic is established 182 182 183 183 === 2.4.4 DS4 – error indicator === 184 184 202 +(% style="width:539px" %) 203 +|(% style="width:176px" %)**State**|(% style="width:360px" %)**Description** 204 +|(% style="width:176px" %)**Blinking red**|(% style="width:360px" %)Errors in communication with BMS Logic 185 185 186 -|(**State**|**Description** 187 -|(**Blinking red**|Errors in communication with BMS Logic 188 - 189 189 === 2.4.5 DS7 – relay 1 indicator === 190 190 191 -|**State**|**Description** 192 -|**Lights green**|Relay #1 is closed 193 -|**Off**|Relay #1 is opened 208 +(% style="width:541px" %) 209 +|(% style="width:179px" %)**State**|(% style="width:359px" %)**Description** 210 +|(% style="width:179px" %)**Lights green**|(% style="width:359px" %)Relay #1 is closed 211 +|(% style="width:179px" %)**Off**|(% style="width:359px" %)Relay #1 is opened 194 194 195 195 === 2.4.6 DS8 – relay 2 indicator === 196 196 197 -|**State**|**Description** 198 -|**Lights green**|Relay #2 is closed 199 -|**Off**|Relay #2 is opened 215 +(% style="width:542px" %) 216 +|(% style="width:180px" %)**State**|(% style="width:359px" %)**Description** 217 +|(% style="width:180px" %)**Lights green**|(% style="width:359px" %)Relay #2 is closed 218 +|(% style="width:180px" %)**Off**|(% style="width:359px" %)Relay #2 is opened 200 200 201 201 === 2.4.7 DS5 – relay 3 indicator === 202 202 203 -|**State**|**Description** 204 -|**Lights green**|Relay #3 is closed 205 -|**Off**|Relay #3 is opened 222 +(% style="width:542px" %) 223 +|(% style="width:183px" %)**State**|(% style="width:356px" %)**Description** 224 +|(% style="width:183px" %)**Lights green**|(% style="width:356px" %)Relay #3 is closed 225 +|(% style="width:183px" %)**Off**|(% style="width:356px" %)Relay #3 is opened 206 206 207 207 === 2.4.8 DS6 – relay 4 indicator === 208 208 209 -|**State**|**Description** 210 -|**Lights green**|Relay #4 is closed 211 -|**Off**|Relay #4 is opened 229 +(% style="width:542px" %) 230 +|(% style="width:187px" %)**State**|(% style="width:352px" %)**Description** 231 +|(% style="width:187px" %)**Lights green**|(% style="width:352px" %)Relay #4 is closed 232 +|(% style="width:187px" %)**Off**|(% style="width:352px" %)Relay #4 is opened 212 212 213 213