Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -2. Connection 1 +2. Connection procedure - Content
-
... ... @@ -1,5 +3,3 @@ 1 -== 2.1 Connection procedure == 2 - 3 3 The mounting area of the BMS Main 2.1 must be protected from mechanical particles (dust, dirt, large objects) and water. The installation site must provide convenient access for subsequent connection to the device’s headers. 4 4 5 5 1. Connect the charging and discharging contactors to the P6-P9 headers. ... ... @@ -7,7 +7,7 @@ 7 7 1. Connect the BMS Main 2.1 to the on-board CAN network. Observe the rules for connecting CAN devices. If the BMS Main 2.1 is the last device on a bus, close pins 1-2 on the P21 jumper, otherwise leave the jumper on pins 2-3. 8 8 1. Connect a power supply to the P1 header. It is not recommended to power the BMS Main 2.1 from the battery only, since at a critical discharge of the battery, it is not possible to turn on the BMS and close the charging contactor. 9 9 10 -= =2.2Headers description ==8 += Headers description = 11 11 12 12 The BMS Main 2.1 headers are shown in figure below. 13 13 ... ... @@ -16,7 +16,7 @@ 16 16 (% class="wikigeneratedid" %) 17 17 Following chapters describes the BMS Main 2.1 headers pinout. 18 18 19 -=== 2.2.1P1 – header for power supply ===17 +=== P1 – header for power supply === 20 20 21 21 [[image:1731516593096-166.png||height="80" width="42"]] 22 22 ... ... @@ -25,7 +25,7 @@ 25 25 |(% style="width:71px" %)**1**|(% style="width:91px" %)**GND**|(% style="width:174px" %)Ground 26 26 |(% style="width:71px" %)**2**|(% style="width:91px" %)**V+**|(% style="width:174px" %)Supply voltage 9-30V 27 27 28 -=== 2.2.2P15 – header for BMS Logic ===26 +=== P15 – header for BMS Logic === 29 29 30 30 [[image:1731516577472-301.png||height="77" width="71"]] 31 31 ... ... @@ -36,7 +36,7 @@ 36 36 |(% style="width:69px" %)**3**|(% style="width:97px" %)**+5V**|(% style="width:355px" %)Supply voltage for BMS Logic 37 37 |(% style="width:69px" %)**4**|(% style="width:97px" %)**GND**|(% style="width:355px" %)Ground 38 38 39 -=== 2.2.3P12 – header for current sensor ===37 +=== P12 – header for current sensor === 40 40 41 41 [[image:1731516685999-633.png||height="74" width="68"]] 42 42 ... ... @@ -47,7 +47,7 @@ 47 47 |(% style="width:75px" %)**3**|(% style="width:93px" %)**Vcs**|(% style="width:360px" %)ADC input (current sensor output) 48 48 |(% style="width:75px" %)**4**|(% style="width:93px" %)**Vref**|(% style="width:360px" %)ADC input (current sensor reference signal) 49 49 50 -=== 2.2.4P13 – header for humidity sensor ===48 +=== P13 – header for humidity sensor === 51 51 52 52 [[image:1731516942455-641.png||height="70" width="64"]] 53 53 ... ... @@ -58,7 +58,7 @@ 58 58 |(% style="width:77px" %)**3**|(% style="width:92px" %)**Vhs**|(% style="width:359px" %)ADC input (humidity sensor output) 59 59 |(% style="width:77px" %)**4**|(% style="width:92px" %)**Vts**|(% style="width:359px" %)ADC input (temperature sensor output) 60 60 61 -=== 2.2.5P8 – header of relay 1 ===59 +=== P8 – header of relay 1 === 62 62 63 63 [[image:1731517023208-641.png||height="80" width="42"]] 64 64 ... ... @@ -69,7 +69,7 @@ 69 69 |(% style="width:82px" %)**1**|(% style="width:91px" %)**V+**|(% style="width:351px" %)Switching voltage (up to 55V, max 2A) 70 70 |(% style="width:82px" %)**2**|(% style="width:91px" %)**NO**|(% style="width:351px" %)Normally open contact 71 71 72 -=== 2.2.6P9 – header of relay 2 ===70 +=== P9 – header of relay 2 === 73 73 74 74 [[image:1731517025702-799.png||height="71" width="37"]] 75 75 ... ... @@ -80,7 +80,7 @@ 80 80 |(% style="width:89px" %)**1**|(% style="width:91px" %)**V+**|(% style="width:341px" %)Switching voltage (up to 55V, max 2A) 81 81 |(% style="width:89px" %)**2**|(% style="width:91px" %)**NO**|(% style="width:341px" %)Normally open contact 82 82 83 -=== 2.2.7P6 – header of relay 3 ===81 +=== P6 – header of relay 3 === 84 84 85 85 [[image:1731517025702-799.png||height="67" width="35"]] 86 86 ... ... @@ -91,7 +91,7 @@ 91 91 |(% style="width:101px" %)**1**|(% style="width:88px" %)**V+**|(% style="width:332px" %)Switching voltage (up to 55V, max 8A) 92 92 |(% style="width:101px" %)**2**|(% style="width:88px" %)**NO**|(% style="width:332px" %)Normally open contact 93 93 94 -=== 2.2.8P7 – header of relay 4 ===92 +=== P7 – header of relay 4 === 95 95 96 96 [[image:1731517025702-799.png||height="65" width="34"]] 97 97 ... ... @@ -102,7 +102,7 @@ 102 102 |(% style="width:102px" %)**1**|(% style="width:93px" %)**V+**|(% style="width:332px" %)Switching voltage (up to 55V, max 8A) 103 103 |(% style="width:102px" %)**2**|(% style="width:93px" %)**NO**|(% style="width:332px" %)Normally open contact 104 104 105 -=== 2.2.9P14 – header for CAN and RS-485 interfaces ===103 +=== P14 – header for CAN and RS-485 interfaces === 106 106 107 107 [[image:1731517180930-597.png||height="81" width="113"]] 108 108 ... ... @@ -115,7 +115,7 @@ 115 115 |(% style="width:107px" %)**5**|(% style="width:127px" %)**CAN_L**|(% style="width:404px" %)CAN L line for communication with external equipment 116 116 |(% style="width:107px" %)**6**|(% style="width:127px" %)**GND_CAN**|(% style="width:404px" %)Ground 117 117 118 -=== 2.2.10P21 – CAN termination resistor jumper ===116 +=== P21 – CAN termination resistor jumper === 119 119 120 120 [[image:1731517188900-976.png||height="78" width="149"]] 121 121 ... ... @@ -126,7 +126,7 @@ 126 126 |**1-2**|(% style="width:122px" %)**120 Ohm**|(% style="width:400px" %)Termination resistor 120 Ohm is connected 127 127 |**2-3**|(% style="width:122px" %)**-**|(% style="width:400px" %)Termination resistor 120 Ohm is not connected 128 128 129 -=== 2.2.11P22 - RS-485 termination resistor jumper ===127 +=== P22 - RS-485 termination resistor jumper === 130 130 131 131 [[image:1731517195672-298.png||height="81" width="155"]] 132 132