Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -2. Connection procedure1 +2. Connection - Content
-
... ... @@ -1,3 +1,5 @@ 1 +== 2.1 Connection procedure == 2 + 1 1 The mounting area of the BMS Main 2.1 must be protected from mechanical particles (dust, dirt, large objects) and water. The installation site must provide convenient access for subsequent connection to the device’s headers. 2 2 3 3 1. Connect the charging and discharging contactors to the P6-P9 headers. ... ... @@ -5,7 +5,7 @@ 5 5 1. Connect the BMS Main 2.1 to the on-board CAN network. Observe the rules for connecting CAN devices. If the BMS Main 2.1 is the last device on a bus, close pins 1-2 on the P21 jumper, otherwise leave the jumper on pins 2-3. 6 6 1. Connect a power supply to the P1 header. It is not recommended to power the BMS Main 2.1 from the battery only, since at a critical discharge of the battery, it is not possible to turn on the BMS and close the charging contactor. 7 7 8 -= Headers description = 10 +== 2.2 Headers description == 9 9 10 10 The BMS Main 2.1 headers are shown in figure below. 11 11 ... ... @@ -14,7 +14,7 @@ 14 14 (% class="wikigeneratedid" %) 15 15 Following chapters describes the BMS Main 2.1 headers pinout. 16 16 17 -=== P1 – header for power supply === 19 +=== 2.2.1 P1 – header for power supply === 18 18 19 19 [[image:1731516593096-166.png||height="80" width="42"]] 20 20 ... ... @@ -23,7 +23,7 @@ 23 23 |(% style="width:71px" %)**1**|(% style="width:91px" %)**GND**|(% style="width:174px" %)Ground 24 24 |(% style="width:71px" %)**2**|(% style="width:91px" %)**V+**|(% style="width:174px" %)Supply voltage 9-30V 25 25 26 -=== P15 – header for BMS Logic === 28 +=== 2.2.2 P15 – header for BMS Logic === 27 27 28 28 [[image:1731516577472-301.png||height="77" width="71"]] 29 29 ... ... @@ -34,7 +34,7 @@ 34 34 |(% style="width:69px" %)**3**|(% style="width:97px" %)**+5V**|(% style="width:355px" %)Supply voltage for BMS Logic 35 35 |(% style="width:69px" %)**4**|(% style="width:97px" %)**GND**|(% style="width:355px" %)Ground 36 36 37 -=== P12 – header for current sensor === 39 +=== 2.2.3 P12 – header for current sensor === 38 38 39 39 [[image:1731516685999-633.png||height="74" width="68"]] 40 40 ... ... @@ -45,7 +45,7 @@ 45 45 |(% style="width:75px" %)**3**|(% style="width:93px" %)**Vcs**|(% style="width:360px" %)ADC input (current sensor output) 46 46 |(% style="width:75px" %)**4**|(% style="width:93px" %)**Vref**|(% style="width:360px" %)ADC input (current sensor reference signal) 47 47 48 -=== P13 – header for humidity sensor === 50 +=== 2.2.4 P13 – header for humidity sensor === 49 49 50 50 [[image:1731516942455-641.png||height="70" width="64"]] 51 51 ... ... @@ -56,7 +56,7 @@ 56 56 |(% style="width:77px" %)**3**|(% style="width:92px" %)**Vhs**|(% style="width:359px" %)ADC input (humidity sensor output) 57 57 |(% style="width:77px" %)**4**|(% style="width:92px" %)**Vts**|(% style="width:359px" %)ADC input (temperature sensor output) 58 58 59 -=== P8 – header of relay 1 === 61 +=== 2.2.5 P8 – header of relay 1 === 60 60 61 61 [[image:1731517023208-641.png||height="80" width="42"]] 62 62 ... ... @@ -67,7 +67,7 @@ 67 67 |(% style="width:82px" %)**1**|(% style="width:91px" %)**V+**|(% style="width:351px" %)Switching voltage (up to 55V, max 2A) 68 68 |(% style="width:82px" %)**2**|(% style="width:91px" %)**NO**|(% style="width:351px" %)Normally open contact 69 69 70 -=== P9 – header of relay 2 === 72 +=== 2.2.6 P9 – header of relay 2 === 71 71 72 72 [[image:1731517025702-799.png||height="71" width="37"]] 73 73 ... ... @@ -78,7 +78,7 @@ 78 78 |(% style="width:89px" %)**1**|(% style="width:91px" %)**V+**|(% style="width:341px" %)Switching voltage (up to 55V, max 2A) 79 79 |(% style="width:89px" %)**2**|(% style="width:91px" %)**NO**|(% style="width:341px" %)Normally open contact 80 80 81 -=== P6 – header of relay 3 === 83 +=== 2.2.7 P6 – header of relay 3 === 82 82 83 83 [[image:1731517025702-799.png||height="67" width="35"]] 84 84 ... ... @@ -89,7 +89,7 @@ 89 89 |(% style="width:101px" %)**1**|(% style="width:88px" %)**V+**|(% style="width:332px" %)Switching voltage (up to 55V, max 8A) 90 90 |(% style="width:101px" %)**2**|(% style="width:88px" %)**NO**|(% style="width:332px" %)Normally open contact 91 91 92 -=== P7 – header of relay 4 === 94 +=== 2.2.8 P7 – header of relay 4 === 93 93 94 94 [[image:1731517025702-799.png||height="65" width="34"]] 95 95 ... ... @@ -100,7 +100,7 @@ 100 100 |(% style="width:102px" %)**1**|(% style="width:93px" %)**V+**|(% style="width:332px" %)Switching voltage (up to 55V, max 8A) 101 101 |(% style="width:102px" %)**2**|(% style="width:93px" %)**NO**|(% style="width:332px" %)Normally open contact 102 102 103 -=== P14 – header for CAN and RS-485 interfaces === 105 +=== 2.2.9 P14 – header for CAN and RS-485 interfaces === 104 104 105 105 [[image:1731517180930-597.png||height="81" width="113"]] 106 106 ... ... @@ -113,7 +113,7 @@ 113 113 |(% style="width:107px" %)**5**|(% style="width:127px" %)**CAN_L**|(% style="width:404px" %)CAN L line for communication with external equipment 114 114 |(% style="width:107px" %)**6**|(% style="width:127px" %)**GND_CAN**|(% style="width:404px" %)Ground 115 115 116 -=== P21 – CAN termination resistor jumper === 118 +=== 2.2.10 P21 – CAN termination resistor jumper === 117 117 118 118 [[image:1731517188900-976.png||height="78" width="149"]] 119 119 ... ... @@ -124,7 +124,7 @@ 124 124 |**1-2**|(% style="width:122px" %)**120 Ohm**|(% style="width:400px" %)Termination resistor 120 Ohm is connected 125 125 |**2-3**|(% style="width:122px" %)**-**|(% style="width:400px" %)Termination resistor 120 Ohm is not connected 126 126 127 -=== P22 - RS-485 termination resistor jumper === 129 +=== 2.2.11 P22 - RS-485 termination resistor jumper === 128 128 129 129 [[image:1731517195672-298.png||height="81" width="155"]] 130 130