Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -Controllers. BMS Main\.1.WebHome1 +Controllers.bms-main-2-1.WebHome - Content
-
... ... @@ -16,7 +16,7 @@ 16 16 17 17 === P1 – header for power supply === 18 18 19 -[[image:1731516593096-166.png]] 19 +[[image:1731516593096-166.png||height="80" width="42"]] 20 20 21 21 (% style="width:339px" %) 22 22 |(% style="width:71px" %)**Pin**|(% style="width:91px" %)**Name**|(% style="width:174px" %)**Description** ... ... @@ -25,7 +25,7 @@ 25 25 26 26 === P15 – header for BMS Logic === 27 27 28 -[[image:1731516577472-301.png]] 28 +[[image:1731516577472-301.png||height="77" width="71"]] 29 29 30 30 (% style="width:524px" %) 31 31 |(% style="width:69px" %)**Pin**|(% style="width:97px" %)**Name**|(% style="width:355px" %)**Description** ... ... @@ -36,7 +36,7 @@ 36 36 37 37 === P12 – header for current sensor === 38 38 39 -[[image:1731516685999-633.png]] 39 +[[image:1731516685999-633.png||height="74" width="68"]] 40 40 41 41 (% style="width:531px" %) 42 42 |(% style="width:75px" %)**Pin**|(% style="width:93px" %)**Name**|(% style="width:360px" %)**Description** ... ... @@ -47,7 +47,7 @@ 47 47 48 48 === P13 – header for humidity sensor === 49 49 50 -[[image:1731516942455-641.png]] 50 +[[image:1731516942455-641.png||height="70" width="64"]] 51 51 52 52 (% style="width:531px" %) 53 53 |(% style="width:77px" %)**Pin**|(% style="width:92px" %)**Name**|(% style="width:359px" %)**Description** ... ... @@ -58,7 +58,7 @@ 58 58 59 59 === P8 – header of relay 1 === 60 60 61 -[[image:1731517023208-641.png]] 61 +[[image:1731517023208-641.png||height="80" width="42"]] 62 62 63 63 By default, relay 1 is used to control the discharging contactor. 64 64 ... ... @@ -69,7 +69,7 @@ 69 69 70 70 === P9 – header of relay 2 === 71 71 72 -[[image:1731517025702-799.png]] 72 +[[image:1731517025702-799.png||height="71" width="37"]] 73 73 74 74 By default, relay 2 is used to output the “Allow charging” signal. 75 75 ... ... @@ -80,7 +80,7 @@ 80 80 81 81 === P6 – header of relay 3 === 82 82 83 -[[image:1731517025702-799.png]] 83 +[[image:1731517025702-799.png||height="67" width="35"]] 84 84 85 85 By default, relay 3 is used to control the charging contactor. 86 86 ... ... @@ -91,7 +91,7 @@ 91 91 92 92 === P7 – header of relay 4 === 93 93 94 -[[image:1731517025702-799.png]] 94 +[[image:1731517025702-799.png||height="65" width="34"]] 95 95 96 96 By default, relay 4 is used to control the heater. 97 97 ... ... @@ -102,7 +102,7 @@ 102 102 103 103 === P14 – header for CAN and RS-485 interfaces === 104 104 105 -[[image:1731517180930-597.png]] 105 +[[image:1731517180930-597.png||height="81" width="113"]] 106 106 107 107 (% style="width:641px" %) 108 108 |(% style="width:107px" %)**Pin**|(% style="width:127px" %)**Name**|(% style="width:404px" %)**Description** ... ... @@ -115,7 +115,7 @@ 115 115 116 116 === P21 – CAN termination resistor jumper === 117 117 118 -[[image:1731517188900-976.png]] 118 +[[image:1731517188900-976.png||height="78" width="149"]] 119 119 120 120 To connect the termination resistor between the lines **CAN_H** and **CAN_L**, install a jumper, according to the P21 pinout: 121 121 ... ... @@ -137,7 +137,7 @@ 137 137 138 138 === P11 – header for discrete inputs/outputs === 139 139 140 -[[image:1731517206246-979.png]] 140 +[[image:1731517206246-979.png||height="81" width="258"]] 141 141 142 142 (% style="width:584px" %) 143 143 |(% style="width:98px" %)**Pin**|(% style="width:157px" %)**Name**|(% style="width:326px" %)**Description**