Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,7 +16,7 @@ 16 16 17 17 === P1 – header for power supply === 18 18 19 -[[image:1731516593096-166.png ||data-xwiki-image-style-alignment="center"]]19 +[[image:1731516593096-166.png]] 20 20 21 21 (% style="width:339px" %) 22 22 |(% style="width:71px" %)**Pin**|(% style="width:91px" %)**Name**|(% style="width:174px" %)**Description** ... ... @@ -25,7 +25,7 @@ 25 25 26 26 === P15 – header for BMS Logic === 27 27 28 -[[image:1731516577472-301.png ||data-xwiki-image-style-alignment="center"]]28 +[[image:1731516577472-301.png]] 29 29 30 30 (% style="width:524px" %) 31 31 |(% style="width:69px" %)**Pin**|(% style="width:97px" %)**Name**|(% style="width:355px" %)**Description** ... ... @@ -36,7 +36,7 @@ 36 36 37 37 === P12 – header for current sensor === 38 38 39 -[[image:1731516685999-633.png ||data-xwiki-image-style-alignment="center"]]39 +[[image:1731516685999-633.png]] 40 40 41 41 (% style="width:531px" %) 42 42 |(% style="width:75px" %)**Pin**|(% style="width:93px" %)**Name**|(% style="width:360px" %)**Description** ... ... @@ -47,7 +47,7 @@ 47 47 48 48 === P13 – header for humidity sensor === 49 49 50 -[[image:1731516942455-641.png ||data-xwiki-image-style-alignment="center"]]50 +[[image:1731516942455-641.png]] 51 51 52 52 (% style="width:531px" %) 53 53 |(% style="width:77px" %)**Pin**|(% style="width:92px" %)**Name**|(% style="width:359px" %)**Description** ... ... @@ -58,7 +58,7 @@ 58 58 59 59 === P8 – header of relay 1 === 60 60 61 -[[image:1731517023208-641.png ||data-xwiki-image-style-alignment="center"]]61 +[[image:1731517023208-641.png]] 62 62 63 63 By default, relay 1 is used to control the discharging contactor. 64 64 ... ... @@ -69,7 +69,7 @@ 69 69 70 70 === P9 – header of relay 2 === 71 71 72 -[[image:1731517025702-799.png ||data-xwiki-image-style-alignment="center"]]72 +[[image:1731517025702-799.png]] 73 73 74 74 By default, relay 2 is used to output the “Allow charging” signal. 75 75 ... ... @@ -80,7 +80,7 @@ 80 80 81 81 === P6 – header of relay 3 === 82 82 83 -[[image:1731517025702-799.png ||data-xwiki-image-style-alignment="center"]]83 +[[image:1731517025702-799.png]] 84 84 85 85 By default, relay 3 is used to control the charging contactor. 86 86 ... ... @@ -91,7 +91,7 @@ 91 91 92 92 === P7 – header of relay 4 === 93 93 94 -[[image:1731517025702-799.png ||data-xwiki-image-style-alignment="center"]]94 +[[image:1731517025702-799.png]] 95 95 96 96 By default, relay 4 is used to control the heater. 97 97 ... ... @@ -102,7 +102,7 @@ 102 102 103 103 === P14 – header for CAN and RS-485 interfaces === 104 104 105 -[[image:1731517180930-597.png ||data-xwiki-image-style-alignment="center"]]105 +[[image:1731517180930-597.png]] 106 106 107 107 (% style="width:641px" %) 108 108 |(% style="width:107px" %)**Pin**|(% style="width:127px" %)**Name**|(% style="width:404px" %)**Description** ... ... @@ -115,94 +115,105 @@ 115 115 116 116 === P21 – CAN termination resistor jumper === 117 117 118 -[[image:1731517188900-976.png ||data-xwiki-image-style-alignment="center"]]118 +[[image:1731517188900-976.png]] 119 119 120 120 To connect the termination resistor between the lines **CAN_H** and **CAN_L**, install a jumper, according to the P21 pinout: 121 121 122 -|**Pin**|**Name**|**Description** 123 -|**1-2**|**120 Ohm**|Termination resistor 120 Ohm is connected 124 -|**2-3**|**-**|Termination resistor 120 Ohm is not connected 122 +(% style="width:643px" %) 123 +|**Pin**|(% style="width:122px" %)**Name**|(% style="width:400px" %)**Description** 124 +|**1-2**|(% style="width:122px" %)**120 Ohm**|(% style="width:400px" %)Termination resistor 120 Ohm is connected 125 +|**2-3**|(% style="width:122px" %)**-**|(% style="width:400px" %)Termination resistor 120 Ohm is not connected 125 125 126 126 === P22 - RS-485 termination resistor jumper === 127 127 128 -[[image:1731517195672-298.png|| data-xwiki-image-style-alignment="center"]]129 +[[image:1731517195672-298.png||height="81" width="155"]] 129 129 130 130 To connect the termination resistor between the **EXT_RS485_A** and **EXT_RS485_B** lines, install a jumper according to the P22 pinout: 131 131 132 -|**Pin**|(% style="width:108px" %)**Name**|(% style="width:1296px" %)**Description** 133 -|**1-2**|(% style="width:108px" %)**120 Ohm**|(% style="width:1296px" %)Terminating resistor 120 Ohm is connected 134 -|**2-3**|(% style="width:108px" %)**-**|(% style="width:1296px" %)Terminating resistor 120 Ohm is not connected 133 +(% style="width:644px" %) 134 +|**Pin**|(% style="width:121px" %)**Name**|(% style="width:402px" %)**Description** 135 +|**1-2**|(% style="width:121px" %)**120 Ohm**|(% style="width:402px" %)Terminating resistor 120 Ohm is connected 136 +|**2-3**|(% style="width:121px" %)**-**|(% style="width:402px" %)Terminating resistor 120 Ohm is not connected 135 135 136 136 === P11 – header for discrete inputs/outputs === 137 137 138 -[[image:1731517206246-979.png ||data-xwiki-image-style-alignment="center"]]140 +[[image:1731517206246-979.png]] 139 139 140 -|**Pin**|**Name**|**Description** 141 -|**16**|**IN_1**|Discrete input #1 “dry contact” (+5V) 142 -|**8**|**GND_1**|Discrete input #1 “dry contact” (ground) 143 -|**15**|**IN_2**|Discrete input #2 “dry contact” (+5V) 144 -|**7**|**GND_2**|Discrete input #2 “dry contact” (ground) 145 -|**14**|**IN_3**|Discrete input #3 “dry contact” (+5V) 146 -|**6**|**GND_3**|Discrete input #3 “dry contact” (ground) 147 -|**13**|**IN_4**|Discrete input #4 “dry contact” (+5V) 148 -|**5**|**GND_4**|Discrete input #4 “dry contact” (ground) 149 -|**12**|**OUT_4**|Discrete output #4 (+5V, 20mA) 150 -|**4**|**GND_OUT_4**|Discrete output #4 (ground) 151 -|**11**|**OUT_3**|Discrete output #3 (+5V, 20mA) 152 -|**3**|**GND_OUT_3**|Discrete output #3 (ground) 153 -|**10**|**OUT_2**|Discrete output #2 (+5V, 20mA) 154 -|**2**|**GND_OUT_2**|Discrete output #2 (ground) 155 -|**9**|**OUT_1**|Discrete output #1 (+5V, 20mA) 156 -|**1**|**GND_OUT_1**|Discrete output #1 (ground) 142 +(% style="width:584px" %) 143 +|(% style="width:98px" %)**Pin**|(% style="width:157px" %)**Name**|(% style="width:326px" %)**Description** 144 +|(% style="width:98px" %)**16**|(% style="width:157px" %)**IN_1**|(% style="width:326px" %)Discrete input #1 “dry contact” (+5V) 145 +|(% style="width:98px" %)**8**|(% style="width:157px" %)**GND_1**|(% style="width:326px" %)Discrete input #1 “dry contact” (ground) 146 +|(% style="width:98px" %)**15**|(% style="width:157px" %)**IN_2**|(% style="width:326px" %)Discrete input #2 “dry contact” (+5V) 147 +|(% style="width:98px" %)**7**|(% style="width:157px" %)**GND_2**|(% style="width:326px" %)Discrete input #2 “dry contact” (ground) 148 +|(% style="width:98px" %)**14**|(% style="width:157px" %)**IN_3**|(% style="width:326px" %)Discrete input #3 “dry contact” (+5V) 149 +|(% style="width:98px" %)**6**|(% style="width:157px" %)**GND_3**|(% style="width:326px" %)Discrete input #3 “dry contact” (ground) 150 +|(% style="width:98px" %)**13**|(% style="width:157px" %)**IN_4**|(% style="width:326px" %)Discrete input #4 “dry contact” (+5V) 151 +|(% style="width:98px" %)**5**|(% style="width:157px" %)**GND_4**|(% style="width:326px" %)Discrete input #4 “dry contact” (ground) 152 +|(% style="width:98px" %)**12**|(% style="width:157px" %)**OUT_4**|(% style="width:326px" %)Discrete output #4 (+5V, 20mA) 153 +|(% style="width:98px" %)**4**|(% style="width:157px" %)**GND_OUT_4**|(% style="width:326px" %)Discrete output #4 (ground) 154 +|(% style="width:98px" %)**11**|(% style="width:157px" %)**OUT_3**|(% style="width:326px" %)Discrete output #3 (+5V, 20mA) 155 +|(% style="width:98px" %)**3**|(% style="width:157px" %)**GND_OUT_3**|(% style="width:326px" %)Discrete output #3 (ground) 156 +|(% style="width:98px" %)**10**|(% style="width:157px" %)**OUT_2**|(% style="width:326px" %)Discrete output #2 (+5V, 20mA) 157 +|(% style="width:98px" %)**2**|(% style="width:157px" %)**GND_OUT_2**|(% style="width:326px" %)Discrete output #2 (ground) 158 +|(% style="width:98px" %)**9**|(% style="width:157px" %)**OUT_1**|(% style="width:326px" %)Discrete output #1 (+5V, 20mA) 159 +|(% style="width:98px" %)**1**|(% style="width:157px" %)**GND_OUT_1**|(% style="width:326px" %)Discrete output #1 (ground) 157 157 158 158 = Indicators = 159 159 160 160 === DS1 – power indicator === 161 161 162 -|**State**|**Description** 163 -|**Lights red**|The device is powered 164 -|**Off**|The device is not powered 165 +(% style="width:442px" %) 166 +|(% style="width:138px" %)**State**|(% style="width:301px" %)**Description** 167 +|(% style="width:138px" %)**Lights red**|(% style="width:301px" %)The device is powered 168 +|(% style="width:138px" %)**Off**|(% style="width:301px" %)The device is not powered 165 165 166 166 === DS2 – operation indicator === 167 167 168 -|**State**|**Description** 169 -|**Blinking green**|The BMS firmware is running 170 -|**Off**|The BMS firmware is not running 172 +(% style="width:442px" %) 173 +|(% style="width:137px" %)**State**|(% style="width:302px" %)**Description** 174 +|(% style="width:137px" %)**Blinking green**|(% style="width:302px" %)The BMS firmware is running 175 +|(% style="width:137px" %)**Off**|(% style="width:302px" %)The BMS firmware is not running 171 171 172 172 === DS3 – communication indicator === 173 173 174 -|**State**|**Description** 175 -|**Blinking yellow (2Hz)**|Initializing communication with BMS Logic boards 176 -|**Blinking yellow (25Hz)**|Communication with BMS Logic is established 179 +(% style="width:539px" %) 180 +|(% style="width:175px" %)**State**|(% style="width:361px" %)**Description** 181 +|(% style="width:175px" %)**Blinking yellow (2Hz)**|(% style="width:361px" %)Initializing communication with BMS Logic boards 182 +|(% style="width:175px" %)**Blinking yellow (25Hz)**|(% style="width:361px" %)Communication with BMS Logic is established 177 177 178 178 === DS4 – error indicator === 179 179 180 -|**State**|**Description** 181 -|**Blinking red**|Errors in communication with BMS Logic 186 +(% style="width:539px" %) 187 +|(% style="width:176px" %)**State**|(% style="width:360px" %)**Description** 188 +|(% style="width:176px" %)**Blinking red**|(% style="width:360px" %)Errors in communication with BMS Logic 182 182 183 183 === DS7 – relay 1 indicator === 184 184 185 -|**State**|**Description** 186 -|**Lights green**|Relay #1 is closed 187 -|**Off**|Relay #1 is opened 192 +(% style="width:541px" %) 193 +|(% style="width:179px" %)**State**|(% style="width:359px" %)**Description** 194 +|(% style="width:179px" %)**Lights green**|(% style="width:359px" %)Relay #1 is closed 195 +|(% style="width:179px" %)**Off**|(% style="width:359px" %)Relay #1 is opened 188 188 189 189 === DS8 – relay 2 indicator === 190 190 191 191 192 -|**State**|**Description** 193 -|**Lights green**|Relay #2 is closed 194 -|**Off**|Relay #2 is opened 200 +(% style="width:542px" %) 201 +|(% style="width:180px" %)**State**|(% style="width:359px" %)**Description** 202 +|(% style="width:180px" %)**Lights green**|(% style="width:359px" %)Relay #2 is closed 203 +|(% style="width:180px" %)**Off**|(% style="width:359px" %)Relay #2 is opened 195 195 196 196 === DS5 – relay 3 indicator === 197 197 198 -|**State**|**Description** 199 -|**Lights green**|Relay #3 is closed 200 -|**Off**|Relay #3 is opened 207 +(% style="width:542px" %) 208 +|(% style="width:183px" %)**State**|(% style="width:356px" %)**Description** 209 +|(% style="width:183px" %)**Lights green**|(% style="width:356px" %)Relay #3 is closed 210 +|(% style="width:183px" %)**Off**|(% style="width:356px" %)Relay #3 is opened 201 201 202 202 === DS6 – relay 4 indicator === 203 203 204 -|**State**|**Description** 205 -|**Lights green**|Relay #4 is closed 206 -|**Off**|Relay #4 is opened 214 +(% style="width:542px" %) 215 +|(% style="width:187px" %)**State**|(% style="width:352px" %)**Description** 216 +|(% style="width:187px" %)**Lights green**|(% style="width:352px" %)Relay #4 is closed 217 +|(% style="width:187px" %)**Off**|(% style="width:352px" %)Relay #4 is opened 207 207 208 208