Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 8 added, 9 removed)
- 1731516474613-418.png
- 1731516577472-301.png
- 1731516593096-166.png
- 1731516685999-633.png
- 1731516942455-641.png
- 1731517023208-641.png
- 1731517025702-799.png
- 1731517206246-979.png
- 1731517946345-632.png
- 1732198397369-222.png
- 1732198827034-560.png
- 1732198890482-787.png
- 1732198896526-660.png
- 1732198937514-731.png
- 1741619628288-759.jpg
- 1741619637854-961.jpg
- 1741619700532-367.png
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -2. Connectionprocedure1 +2. Installation and connection - Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Controllers.BMS Main 2\.1.WebHome1 +Battery management systems.BMS Main 2\.1.WebHome - Content
-
... ... @@ -1,3 +1,20 @@ 1 +(% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Installation and connection = 3 + 4 +== Installation procedure == 5 + 6 +Overall and mounting dimensions of the BMS Main 2.1 are shown below. 7 + 8 +[[image:1732198397369-222.png||data-xwiki-image-style-alignment="center" height="393" width="556"]] 9 + 10 +(% style="width:494px" %) 11 +|**Parameter**|(% style="width:178px" %)**Value** 12 +|Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 32 13 +|Mounting dimensions (length × width), mm|(% style="width:178px" %)114 × 114 14 +|Mounting holes|(% style="width:178px" %)M3 15 + 16 +== Connection procedure == 17 + 1 1 The mounting area of the BMS Main 2.1 must be protected from mechanical particles (dust, dirt, large objects) and water. The installation site must provide convenient access for subsequent connection to the device’s headers. 2 2 3 3 1. Connect the charging and discharging contactors to the P6-P9 headers. ... ... @@ -5,50 +5,58 @@ 5 5 1. Connect the BMS Main 2.1 to the on-board CAN network. Observe the rules for connecting CAN devices. If the BMS Main 2.1 is the last device on a bus, close pins 1-2 on the P21 jumper, otherwise leave the jumper on pins 2-3. 6 6 1. Connect a power supply to the P1 header. It is not recommended to power the BMS Main 2.1 from the battery only, since at a critical discharge of the battery, it is not possible to turn on the BMS and close the charging contactor. 7 7 8 -= Headers description = 25 +== Headers description == 9 9 10 10 The BMS Main 2.1 headers are shown in figure below. 11 11 12 -[[ The BMS Main 2.1 headers>>image:1731517946345-632.png||height="417" width="451"]]29 +[[image:1731516393377-928.jpeg||alt="1731517946345-632.png" data-xwiki-image-style-alignment="center" height="417" width="451"]] 13 13 14 -(% class="wikigeneratedid" %) 15 -Following chapters describes the BMS Main 2.1 headers pinout. 31 +(% class="box warningmessage" %) 32 +((( 33 +**Attention!** 34 +All headers are shown from the device side! 35 +))) 16 16 17 17 === P1 – header for power supply === 18 18 19 - [[image:1731516593096-166.png||data-xwiki-image-style-alignment="center"]]39 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 20 20 21 -(% style="width:339px" %) 22 -|(% style="width:71px" %)**Pin**|(% style="width:91px" %)**Name**|(% style="width:174px" %)**Description** 23 -|(% style="width:71px" %)**1**|(% style="width:91px" %)**GND**|(% style="width:174px" %)Ground 24 -|(% style="width:71px" %)**2**|(% style="width:91px" %)**V+**|(% style="width:174px" %)Supply voltage 9-30V 41 +[[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 25 25 43 +|**Pin**|**Name**|**Description** 44 +|**1**|**GND**|Ground 45 +|**2**|**V+**|Supply voltage 9-30V 46 + 26 26 === P15 – header for BMS Logic === 27 27 28 - [[image:1731516577472-301.png||data-xwiki-image-style-alignment="center"]]49 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 29 29 30 -(% style="width:524px" %) 31 -|(% style="width:69px" %)**Pin**|(% style="width:97px" %)**Name**|(% style="width:355px" %)**Description** 32 -|(% style="width:69px" %)**1**|(% style="width:97px" %)**RS485_A**|(% style="width:355px" %)RS-485 line A for communication with BMS Logic 33 -|(% style="width:69px" %)**2**|(% style="width:97px" %)**RS485_B**|(% style="width:355px" %)RS-485 line B for communication with BMS Logic 34 -|(% style="width:69px" %)**3**|(% style="width:97px" %)**+5V**|(% style="width:355px" %)Supply voltage for BMS Logic 35 -|(% style="width:69px" %)**4**|(% style="width:97px" %)**GND**|(% style="width:355px" %)Ground 51 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 36 36 53 +|**Pin**|**Name**|**Description** 54 +|**1**|**RS485_A**|RS-485 line A for communication with BMS Logic 55 +|**2**|**RS485_B**|RS-485 line B for communication with BMS Logic 56 +|**3**|**+5V**|Supply voltage for BMS Logic 57 +|**4**|**GND**|Ground 58 + 37 37 === P12 – header for current sensor === 38 38 39 - [[image:1731516685999-633.png||data-xwiki-image-style-alignment="center"]]61 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 40 40 41 -(% style="width:531px" %) 42 -|(% style="width:75px" %)**Pin**|(% style="width:93px" %)**Name**|(% style="width:360px" %)**Description** 43 -|(% style="width:75px" %)**1**|(% style="width:93px" %)**+5V**|(% style="width:360px" %)Supply voltage for the current sensor 5V, max 50 mA 44 -|(% style="width:75px" %)**2**|(% style="width:93px" %)**GND**|(% style="width:360px" %)Ground 45 -|(% style="width:75px" %)**3**|(% style="width:93px" %)**Vcs**|(% style="width:360px" %)ADC input (current sensor output) 46 -|(% style="width:75px" %)**4**|(% style="width:93px" %)**Vref**|(% style="width:360px" %)ADC input (current sensor reference signal) 63 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 47 47 65 +|**Pin**|**Name**|**Description** 66 +|**1**|**+5V**|Supply voltage for the current sensor 5V, max 50 mA 67 +|**2**|**GND**|Ground 68 +|**3**|**Vcs**|ADC input (current sensor output) 69 +|**4**|**Vref**|ADC input (current sensor reference signal) 70 + 48 48 === P13 – header for humidity sensor === 49 49 50 - [[image:1731516942455-641.png||data-xwiki-image-style-alignment="center"]]73 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 51 51 75 +[[image:1732198896526-660.png||data-xwiki-image-style-alignment="center" height="70" width="64"]] 76 + 52 52 |**Pin**|**Name**|**Description** 53 53 |**1**|**+5V**|Supply voltage 5 V, max 50 mA 54 54 |**2**|**GND**|Ground ... ... @@ -57,48 +57,63 @@ 57 57 58 58 === P8 – header of relay 1 === 59 59 60 - [[image:1731517023208-641.png||data-xwiki-image-style-alignment="center"]]85 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 61 61 87 +[[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 88 + 62 62 By default, relay 1 is used to control the discharging contactor. 63 63 64 64 |**Pin**|**Name**|**Description** 65 -|**1**|**V+**|Switching voltage (up to 55V, max 2A)92 +|**1**|**V+**|Switching voltage (up to 55V, max 3A) 66 66 |**2**|**NO**|Normally open contact 67 67 95 +Contactor 96 + 68 68 === P9 – header of relay 2 === 69 69 70 - [[image:1731517025702-799.png||data-xwiki-image-style-alignment="center"]]99 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 71 71 101 +[[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 102 + 72 72 By default, relay 2 is used to output the “Allow charging” signal. 73 73 74 74 |**Pin**|**Name**|**Description** 75 -|**1**|**V+**|Switching voltage (up to 55V, max 2A)106 +|**1**|**V+**|Switching voltage (up to 55V, max 3A) 76 76 |**2**|**NO**|Normally open contact 77 77 78 78 === P6 – header of relay 3 === 79 79 80 - [[image:1731517025702-799.png||data-xwiki-image-style-alignment="center"]]111 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 81 81 113 +[[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 114 + 82 82 By default, relay 3 is used to control the charging contactor. 83 83 84 84 |**Pin**|**Name**|**Description** 85 -|**1**|**V+**|Switching voltage (up to 55V, max 8A) 118 +|**1**|**V+**|Switching voltage up to 55V, 119 +up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 86 86 |**2**|**NO**|Normally open contact 87 87 88 88 === P7 – header of relay 4 === 89 89 90 - [[image:1731517025702-799.png||data-xwiki-image-style-alignment="center"]]124 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 91 91 126 +[[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 127 + 92 92 By default, relay 4 is used to control the heater. 93 93 94 94 |**Pin**|**Name**|**Description** 95 -|**1**|**V+**|Switching voltage (up to 55V, max 8A) 131 +|**1**|**V+**|Switching voltage up to 55V, 132 +up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 96 96 |**2**|**NO**|Normally open contact 97 97 98 98 === P14 – header for CAN and RS-485 interfaces === 99 99 100 - [[image:1731517180930-597.png||data-xwiki-image-style-alignment="center"]]137 +Receptacle Housing: Molex 430250600. Terminals: Molex 43030 101 101 139 +[[image:1731517180930-597.png||data-xwiki-image-style-alignment="center" height="81" width="113"]] 140 + 141 +(% style="width:641px" %) 102 102 |**Pin**|**Name**|**Description** 103 103 |**1**|**EXT_RS485_A**|RS-485 line A for communication with external equipment 104 104 |**2**|**CAN_H**|CAN H line for communication with external equipment ... ... @@ -109,7 +109,7 @@ 109 109 110 110 === P21 – CAN termination resistor jumper === 111 111 112 -[[image:1731517188900-976.png||data-xwiki-image-style-alignment="center"]] 152 +[[image:1731517188900-976.png||data-xwiki-image-style-alignment="center" height="78" width="149"]] 113 113 114 114 To connect the termination resistor between the lines **CAN_H** and **CAN_L**, install a jumper, according to the P21 pinout: 115 115 ... ... @@ -119,7 +119,7 @@ 119 119 120 120 === P22 - RS-485 termination resistor jumper === 121 121 122 -[[image:1731517195672-298.png||data-xwiki-image-style-alignment="center"]] 162 +[[image:1731517195672-298.png||data-xwiki-image-style-alignment="center" height="81" width="155"]] 123 123 124 124 To connect the termination resistor between the **EXT_RS485_A** and **EXT_RS485_B** lines, install a jumper according to the P22 pinout: 125 125 ... ... @@ -129,8 +129,10 @@ 129 129 130 130 === P11 – header for discrete inputs/outputs === 131 131 132 - [[image:1731517206246-979.png||data-xwiki-image-style-alignment="center"]]172 +Receptacle Housing: Molex 430251600. Terminals: Molex 43030 133 133 174 +[[image:1732198937514-731.png||data-xwiki-image-style-alignment="center" height="85" width="272"]] 175 + 134 134 |**Pin**|**Name**|**Description** 135 135 |**16**|**IN_1**|Discrete input #1 “dry contact” (+5V) 136 136 |**8**|**GND_1**|Discrete input #1 “dry contact” (ground) ... ... @@ -149,7 +149,7 @@ 149 149 |**9**|**OUT_1**|Discrete output #1 (+5V, 20mA) 150 150 |**1**|**GND_OUT_1**|Discrete output #1 (ground) 151 151 152 -= Indicators = 194 +== Indicators == 153 153 154 154 === DS1 – power indicator === 155 155 ... ... @@ -171,9 +171,10 @@ 171 171 172 172 === DS4 – error indicator === 173 173 174 -|**State**|**Description** 175 -|**Blinking red**|Errors in communication with BMS Logic 176 176 217 +|(**State**|**Description** 218 +|(**Blinking red**|Errors in communication with BMS Logic 219 + 177 177 === DS7 – relay 1 indicator === 178 178 179 179 |**State**|**Description** ... ... @@ -182,7 +182,6 @@ 182 182 183 183 === DS8 – relay 2 indicator === 184 184 185 - 186 186 |**State**|**Description** 187 187 |**Lights green**|Relay #2 is closed 188 188 |**Off**|Relay #2 is opened
- 1731516474613-418.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -981 bytes - Content
- 1731516577472-301.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.5 KB - Content
- 1731516593096-166.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -981 bytes - Content
- 1731516685999-633.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.5 KB - Content
- 1731516942455-641.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.5 KB - Content
- 1731517023208-641.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -981 bytes - Content
- 1731517025702-799.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -981 bytes - Content
- 1731517206246-979.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -4.2 KB - Content
- 1731517946345-632.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -107.3 KB - Content
- 1732198397369-222.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +81.3 KB - Content
- 1732198827034-560.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.1 KB - Content
- 1732198890482-787.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.0 KB - Content
- 1732198896526-660.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.0 KB - Content
- 1732198937514-731.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.1 KB - Content
- 1741619628288-759.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.2 KB - Content
- 1741619637854-961.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.2 KB - Content
- 1741619700532-367.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.1 KB - Content