Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -2. Connection 1 +2. Connection procedure - Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Additional modules.BMS Main 2\.1.WebHome1 +Controllers.BMS Main 2\.1.WebHome - Content
-
... ... @@ -1,46 +1,60 @@ 1 - =Headers=1 +The mounting area of the BMS Main 2.1 must be protected from mechanical particles (dust, dirt, large objects) and water. The installation site must provide convenient access for subsequent connection to the device’s headers. 2 2 3 +1. Connect the charging and discharging contactors to the P6-P9 headers. 4 +1. Connect a current sensor to the P12 header according to its documentation. The positive current direction (indicated by an arrow on the sensor) corresponds to the battery charging. It is recommended to use a shielded cable to connect the current sensor, the shield should be grounded on the side of the current sensor. The cable should be positioned as far as possible from the high current circuits. If the current sensor has a reference voltage line, connect it to pin 4 of the P12 header. 5 +1. Connect the BMS Main 2.1 to the on-board CAN network. Observe the rules for connecting CAN devices. If the BMS Main 2.1 is the last device on a bus, close pins 1-2 on the P21 jumper, otherwise leave the jumper on pins 2-3. 6 +1. Connect a power supply to the P1 header. It is not recommended to power the BMS Main 2.1 from the battery only, since at a critical discharge of the battery, it is not possible to turn on the BMS and close the charging contactor. 7 + 8 += Headers description = 9 + 3 3 The BMS Main 2.1 headers are shown in figure below. 4 4 5 5 [[The BMS Main 2.1 headers>>image:1731517946345-632.png||height="417" width="451"]] 6 6 14 +(% class="wikigeneratedid" %) 15 +Following chapters describes the BMS Main 2.1 headers pinout. 16 + 7 7 === P1 – header for power supply === 8 8 9 9 [[image:1731516593096-166.png||data-xwiki-image-style-alignment="center"]] 10 10 11 -|**Pin**|**Name**|**Description** 12 -|**1**|**GND**|Ground 13 -|**2**|**V+**|Supply voltage 9-30V 21 +(% style="width:339px" %) 22 +|(% style="width:71px" %)**Pin**|(% style="width:91px" %)**Name**|(% style="width:174px" %)**Description** 23 +|(% style="width:71px" %)**1**|(% style="width:91px" %)**GND**|(% style="width:174px" %)Ground 24 +|(% style="width:71px" %)**2**|(% style="width:91px" %)**V+**|(% style="width:174px" %)Supply voltage 9-30V 14 14 15 15 === P15 – header for BMS Logic === 16 16 17 17 [[image:1731516577472-301.png||data-xwiki-image-style-alignment="center"]] 18 18 19 -|**Pin**|**Name**|**Description** 20 -|**1**|**RS485_A**|RS-485 line A for communication with BMS Logic 21 -|**2**|**RS485_B**|RS-485 line B for communication with BMS Logic 22 -|**3**|**+5V**|Supply voltage for BMS Logic 23 -|**4**|**GND**|Ground 30 +(% style="width:524px" %) 31 +|(% style="width:69px" %)**Pin**|(% style="width:97px" %)**Name**|(% style="width:355px" %)**Description** 32 +|(% style="width:69px" %)**1**|(% style="width:97px" %)**RS485_A**|(% style="width:355px" %)RS-485 line A for communication with BMS Logic 33 +|(% style="width:69px" %)**2**|(% style="width:97px" %)**RS485_B**|(% style="width:355px" %)RS-485 line B for communication with BMS Logic 34 +|(% style="width:69px" %)**3**|(% style="width:97px" %)**+5V**|(% style="width:355px" %)Supply voltage for BMS Logic 35 +|(% style="width:69px" %)**4**|(% style="width:97px" %)**GND**|(% style="width:355px" %)Ground 24 24 25 25 === P12 – header for current sensor === 26 26 27 27 [[image:1731516685999-633.png||data-xwiki-image-style-alignment="center"]] 28 28 29 -|**Pin**|**Name**|**Description** 30 -|**1**|**+5V**|Supply voltage for the current sensor 5V, max 50 mA 31 -|**2**|**GND**|Ground 32 -|**3**|**Vcs**|ADC input (current sensor output) 33 -|**4**|**Vref**|ADC input (current sensor reference signal) 41 +(% style="width:531px" %) 42 +|(% style="width:75px" %)**Pin**|(% style="width:93px" %)**Name**|(% style="width:360px" %)**Description** 43 +|(% style="width:75px" %)**1**|(% style="width:93px" %)**+5V**|(% style="width:360px" %)Supply voltage for the current sensor 5V, max 50 mA 44 +|(% style="width:75px" %)**2**|(% style="width:93px" %)**GND**|(% style="width:360px" %)Ground 45 +|(% style="width:75px" %)**3**|(% style="width:93px" %)**Vcs**|(% style="width:360px" %)ADC input (current sensor output) 46 +|(% style="width:75px" %)**4**|(% style="width:93px" %)**Vref**|(% style="width:360px" %)ADC input (current sensor reference signal) 34 34 35 35 === P13 – header for humidity sensor === 36 36 37 37 [[image:1731516942455-641.png||data-xwiki-image-style-alignment="center"]] 38 38 39 -|**Pin**|**Name**|**Description** 40 -|**1**|**+5V**|Supply voltage 5 V, max 50 mA 41 -|**2**|**GND**|Ground 42 -|**3**|**Vhs**|ADC input (humidity sensor output) 43 -|**4**|**Vts**|ADC input (temperature sensor output) 52 +(% style="width:531px" %) 53 +|(% style="width:77px" %)**Pin**|(% style="width:92px" %)**Name**|(% style="width:359px" %)**Description** 54 +|(% style="width:77px" %)**1**|(% style="width:92px" %)**+5V**|(% style="width:359px" %)Supply voltage 5 V, max 50 mA 55 +|(% style="width:77px" %)**2**|(% style="width:92px" %)**GND**|(% style="width:359px" %)Ground 56 +|(% style="width:77px" %)**3**|(% style="width:92px" %)**Vhs**|(% style="width:359px" %)ADC input (humidity sensor output) 57 +|(% style="width:77px" %)**4**|(% style="width:92px" %)**Vts**|(% style="width:359px" %)ADC input (temperature sensor output) 44 44 45 45 === P8 – header of relay 1 === 46 46 ... ... @@ -48,9 +48,10 @@ 48 48 49 49 By default, relay 1 is used to control the discharging contactor. 50 50 51 -|**Pin**|**Name**|**Description** 52 -|**1**|**V+**|Switching voltage (up to 55V, max 2A) 53 -|**2**|**NO**|Normally open contact 65 +(% style="width:527px" %) 66 +|(% style="width:82px" %)**Pin**|(% style="width:91px" %)**Name**|(% style="width:351px" %)**Description** 67 +|(% style="width:82px" %)**1**|(% style="width:91px" %)**V+**|(% style="width:351px" %)Switching voltage (up to 55V, max 2A) 68 +|(% style="width:82px" %)**2**|(% style="width:91px" %)**NO**|(% style="width:351px" %)Normally open contact 54 54 55 55 === P9 – header of relay 2 === 56 56 ... ... @@ -58,9 +58,10 @@ 58 58 59 59 By default, relay 2 is used to output the “Allow charging” signal. 60 60 61 -|**Pin**|**Name**|**Description** 62 -|**1**|**V+**|Switching voltage (up to 55V, max 2A) 63 -|**2**|**NO**|Normally open contact 76 +(% style="width:524px" %) 77 +|(% style="width:89px" %)**Pin**|(% style="width:91px" %)**Name**|(% style="width:341px" %)**Description** 78 +|(% style="width:89px" %)**1**|(% style="width:91px" %)**V+**|(% style="width:341px" %)Switching voltage (up to 55V, max 2A) 79 +|(% style="width:89px" %)**2**|(% style="width:91px" %)**NO**|(% style="width:341px" %)Normally open contact 64 64 65 65 === P6 – header of relay 3 === 66 66 ... ... @@ -68,9 +68,10 @@ 68 68 69 69 By default, relay 3 is used to control the charging contactor. 70 70 71 -|**Pin**|**Name**|**Description** 72 -|**1**|**V+**|Switching voltage (up to 55V, max 8A) 73 -|**2**|**NO**|Normally open contact 87 +(% style="width:524px" %) 88 +|(% style="width:101px" %)**Pin**|(% style="width:88px" %)**Name**|(% style="width:332px" %)**Description** 89 +|(% style="width:101px" %)**1**|(% style="width:88px" %)**V+**|(% style="width:332px" %)Switching voltage (up to 55V, max 8A) 90 +|(% style="width:101px" %)**2**|(% style="width:88px" %)**NO**|(% style="width:332px" %)Normally open contact 74 74 75 75 === P7 – header of relay 4 === 76 76 ... ... @@ -78,21 +78,23 @@ 78 78 79 79 By default, relay 4 is used to control the heater. 80 80 81 -**Pin**|**Name**|**Description** 82 -**1**|**V+**|Switching voltage (up to 55V, max 8A) 83 -**2**|**NO**|Normally open contact 98 +(% style="width:530px" %) 99 +|(% style="width:102px" %)**Pin**|(% style="width:93px" %)**Name**|(% style="width:332px" %)**Description** 100 +|(% style="width:102px" %)**1**|(% style="width:93px" %)**V+**|(% style="width:332px" %)Switching voltage (up to 55V, max 8A) 101 +|(% style="width:102px" %)**2**|(% style="width:93px" %)**NO**|(% style="width:332px" %)Normally open contact 84 84 85 85 === P14 – header for CAN and RS-485 interfaces === 86 86 87 87 [[image:1731517180930-597.png||data-xwiki-image-style-alignment="center"]] 88 88 89 -|**Pin**|**Name**|**Description** 90 -|**1**|**EXT_RS485_A**|RS-485 line A for communication with external equipment 91 -|**2**|**CAN_H**|CAN H line for communication with external equipment 92 -|**3**|**+5V_CAN**|Supply voltage 5V for external devices, max 200 mA 93 -|**4**|**EXT_RS485_B**|RS-485 line B for communication with external equipment 94 -|**5**|**CAN_L**|CAN L line for communication with external equipment 95 -|**6**|**GND_CAN**|Ground 107 +(% style="width:641px" %) 108 +|(% style="width:107px" %)**Pin**|(% style="width:127px" %)**Name**|(% style="width:404px" %)**Description** 109 +|(% style="width:107px" %)**1**|(% style="width:127px" %)**EXT_RS485_A**|(% style="width:404px" %)RS-485 line A for communication with external equipment 110 +|(% style="width:107px" %)**2**|(% style="width:127px" %)**CAN_H**|(% style="width:404px" %)CAN H line for communication with external equipment 111 +|(% style="width:107px" %)**3**|(% style="width:127px" %)**+5V_CAN**|(% style="width:404px" %)Supply voltage 5V for external devices, max 200 mA 112 +|(% style="width:107px" %)**4**|(% style="width:127px" %)**EXT_RS485_B**|(% style="width:404px" %)RS-485 line B for communication with external equipment 113 +|(% style="width:107px" %)**5**|(% style="width:127px" %)**CAN_L**|(% style="width:404px" %)CAN L line for communication with external equipment 114 +|(% style="width:107px" %)**6**|(% style="width:127px" %)**GND_CAN**|(% style="width:404px" %)Ground 96 96 97 97 === P21 – CAN termination resistor jumper === 98 98 ... ... @@ -110,9 +110,9 @@ 110 110 111 111 To connect the termination resistor between the **EXT_RS485_A** and **EXT_RS485_B** lines, install a jumper according to the P22 pinout: 112 112 113 -|**Pin**|**Name**|**Description** 114 -|**1-2**|**120 Ohm**|Terminating resistor 120 Ohm is connected 115 -|**2-3**|**-**|Terminating resistor 120 Ohm is not connected 132 +|**Pin**|(% style="width:108px" %)**Name**|(% style="width:1296px" %)**Description** 133 +|**1-2**|(% style="width:108px" %)**120 Ohm**|(% style="width:1296px" %)Terminating resistor 120 Ohm is connected 134 +|**2-3**|(% style="width:108px" %)**-**|(% style="width:1296px" %)Terminating resistor 120 Ohm is not connected 116 116 117 117 === P11 – header for discrete inputs/outputs === 118 118