Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -26,21 +26,21 @@ 26 26 27 27 [[image:1731516685999-633.png||data-xwiki-image-style-alignment="center"]] 28 28 29 -|(% style="width:100px" %)**Pin**| (% style="width:293px" %)**Name**|(% style="width:1129px" %)**Description**30 -|(% style="width:100px" %)**1**| (% style="width:293px" %)**+5V**|(% style="width:1129px" %)Supply voltage for the current sensor 5V, max 50 mA31 -|(% style="width:100px" %)**2**| (% style="width:293px" %)**GND**|(% style="width:1129px" %)Ground32 -|(% style="width:100px" %)**3**| (% style="width:293px" %)**Vcs**|(% style="width:1129px" %)ADC input (current sensor output)33 -|(% style="width:100px" %)**4**| (% style="width:293px" %)**Vref**|(% style="width:1129px" %)ADC input (current sensor reference signal)29 +|(% style="width:100px" %)**Pin**|**Name**|**Description** 30 +|(% style="width:100px" %)**1**|**+5V**|Supply voltage for the current sensor 5V, max 50 mA 31 +|(% style="width:100px" %)**2**|**GND**|Ground 32 +|(% style="width:100px" %)**3**|**Vcs**|ADC input (current sensor output) 33 +|(% style="width:100px" %)**4**|**Vref**|ADC input (current sensor reference signal) 34 34 35 35 === P13 – header for humidity sensor === 36 36 37 37 [[image:1731516942455-641.png||data-xwiki-image-style-alignment="center"]] 38 38 39 -|(% style="width:100px" %)**Pin**| (% style="width:292px" %)**Name**|(% style="width:1130px" %)**Description**40 -|(% style="width:100px" %)**1**| (% style="width:292px" %)**+5V**|(% style="width:1130px" %)Supply voltage 5 V, max 50 mA41 -|(% style="width:100px" %)**2**| (% style="width:292px" %)**GND**|(% style="width:1130px" %)Ground42 -|(% style="width:100px" %)**3**| (% style="width:292px" %)**Vhs**|(% style="width:1130px" %)ADC input (humidity sensor output)43 -|(% style="width:100px" %)**4**| (% style="width:292px" %)**Vts**|(% style="width:1130px" %)ADC input (temperature sensor output)39 +|(% style="width:100px" %)**Pin**|**Name**|**Description** 40 +|(% style="width:100px" %)**1**|**+5V**|Supply voltage 5 V, max 50 mA 41 +|(% style="width:100px" %)**2**|**GND**|Ground 42 +|(% style="width:100px" %)**3**|**Vhs**|ADC input (humidity sensor output) 43 +|(% style="width:100px" %)**4**|**Vts**|ADC input (temperature sensor output) 44 44 45 45 === P8 – header of relay 1 === 46 46 ... ... @@ -48,9 +48,9 @@ 48 48 49 49 By default, relay 1 is used to control the discharging contactor. 50 50 51 -|(% style="width:100px" %)**Pin**| (% style="width:291px" %)**Name**|(% style="width:1131px" %)**Description**52 -|(% style="width:100px" %)**1**| (% style="width:291px" %)**V+**|(% style="width:1131px" %)Switching voltage (up to 55V, max 2A)53 -|(% style="width:100px" %)**2**| (% style="width:291px" %)**NO**|(% style="width:1131px" %)Normally open contact51 +|(% style="width:100px" %)**Pin**|**Name**|**Description** 52 +|(% style="width:100px" %)**1**|**V+**|Switching voltage (up to 55V, max 2A) 53 +|(% style="width:100px" %)**2**|**NO**|Normally open contact 54 54 55 55 === P9 – header of relay 2 === 56 56 ... ... @@ -58,9 +58,9 @@ 58 58 59 59 By default, relay 2 is used to output the “Allow charging” signal. 60 60 61 -|(% style="width:100px" %)**Pin**| (% style="width:297px" %)**Name**|(% style="width:1125px" %)**Description**62 -|(% style="width:100px" %)**1**| (% style="width:297px" %)**V+**|(% style="width:1125px" %)Switching voltage (up to 55V, max 2A)63 -|(% style="width:100px" %)**2**| (% style="width:297px" %)**NO**|(% style="width:1125px" %)Normally open contact61 +|(% style="width:100px" %)**Pin**|**Name**|**Description** 62 +|(% style="width:100px" %)**1**|**V+**|Switching voltage (up to 55V, max 2A) 63 +|(% style="width:100px" %)**2**|**NO**|Normally open contact 64 64 65 65 === P6 – header of relay 3 === 66 66 ... ... @@ -68,9 +68,9 @@ 68 68 69 69 By default, relay 3 is used to control the charging contactor. 70 70 71 -|(% style="width:100px" %)**Pin**| (% style="width:297px" %)**Name**|(% style="width:1125px" %)**Description**72 -|(% style="width:100px" %)**1**| (% style="width:297px" %)**V+**|(% style="width:1125px" %)Switching voltage (up to 55V, max 8A)73 -|(% style="width:100px" %)**2**| (% style="width:297px" %)**NO**|(% style="width:1125px" %)Normally open contact71 +|(% style="width:100px" %)**Pin**|**Name**|**Description** 72 +|(% style="width:100px" %)**1**|**V+**|Switching voltage (up to 55V, max 8A) 73 +|(% style="width:100px" %)**2**|**NO**|Normally open contact 74 74 75 75 === P7 – header of relay 4 === 76 76 ... ... @@ -78,9 +78,9 @@ 78 78 79 79 By default, relay 4 is used to control the heater. 80 80 81 -|(% style="width:100px" %)**Pin**| (% style="width:298px" %)**Name**|(% style="width:1124px" %)**Description**82 -|(% style="width:100px" %)**1**| (% style="width:298px" %)**V+**|(% style="width:1124px" %)Switching voltage (up to 55V, max 8A)83 -|(% style="width:100px" %)**2**| (% style="width:298px" %)**NO**|(% style="width:1124px" %)Normally open contact81 +|(% style="width:100px" %)**Pin**|**Name**|**Description** 82 +|(% style="width:100px" %)**1**|**V+**|Switching voltage (up to 55V, max 8A) 83 +|(% style="width:100px" %)**2**|**NO**|Normally open contact 84 84 85 85 === P14 – header for CAN and RS-485 interfaces === 86 86 ... ... @@ -100,9 +100,9 @@ 100 100 101 101 To connect the termination resistor between the lines **CAN_H** and **CAN_L**, install a jumper, according to the P21 pinout: 102 102 103 -|(% style="width:100px" %)**Pin**| (% style="width:299px" %)**Name**|(% style="width:1123px" %)**Description**104 -|(% style="width:100px" %)**1-2**| (% style="width:299px" %)**120 Ohm**|(% style="width:1123px" %)Termination resistor 120 Ohm is connected105 -|(% style="width:100px" %)**2-3**| (% style="width:299px" %)**-**|(% style="width:1123px" %)Termination resistor 120 Ohm is not connected103 +|(% style="width:100px" %)**Pin**|**Name**|**Description** 104 +|(% style="width:100px" %)**1-2**|**120 Ohm**|Termination resistor 120 Ohm is connected 105 +|(% style="width:100px" %)**2-3**|**-**|Termination resistor 120 Ohm is not connected 106 106 107 107 === P22 - RS-485 termination resistor jumper === 108 108 ... ... @@ -110,31 +110,31 @@ 110 110 111 111 To connect the termination resistor between the **EXT_RS485_A** and **EXT_RS485_B** lines, install a jumper according to the P22 pinout: 112 112 113 -|(% style="width:100px" %)**Pin**| (% style="width:301px" %)**Name**|(% style="width:1121px" %)**Description**114 -|(% style="width:100px" %)**1-2**| (% style="width:301px" %)**120 Ohm**|(% style="width:1121px" %)Terminating resistor 120 Ohm is connected115 -|(% style="width:100px" %)**2-3**| (% style="width:301px" %)**-**|(% style="width:1121px" %)Terminating resistor 120 Ohm is not connected113 +|(% style="width:100px" %)**Pin**|**Name**|**Description** 114 +|(% style="width:100px" %)**1-2**|**120 Ohm**|Terminating resistor 120 Ohm is connected 115 +|(% style="width:100px" %)**2-3**|**-**|Terminating resistor 120 Ohm is not connected 116 116 117 117 === P11 – header for discrete inputs/outputs === 118 118 119 119 [[image:1731517206246-979.png||data-xwiki-image-style-alignment="center"]] 120 120 121 -|(% style="width:100px" %)**Pin**| (% style="width:310px" %)**Name**|(% style="width:1112px" %)**Description**122 -|(% style="width:100px" %)**16**| (% style="width:310px" %)**IN_1**|(% style="width:1112px" %)Discrete input #1 “dry contact” (+5V)123 -|(% style="width:100px" %)**8**| (% style="width:310px" %)**GND_1**|(% style="width:1112px" %)Discrete input #1 “dry contact” (ground)124 -|(% style="width:100px" %)**15**| (% style="width:310px" %)**IN_2**|(% style="width:1112px" %)Discrete input #2 “dry contact” (+5V)125 -|(% style="width:100px" %)**7**| (% style="width:310px" %)**GND_2**|(% style="width:1112px" %)Discrete input #2 “dry contact” (ground)126 -|(% style="width:100px" %)**14**| (% style="width:310px" %)**IN_3**|(% style="width:1112px" %)Discrete input #3 “dry contact” (+5V)127 -|(% style="width:100px" %)**6**| (% style="width:310px" %)**GND_3**|(% style="width:1112px" %)Discrete input #3 “dry contact” (ground)128 -|(% style="width:100px" %)**13**| (% style="width:310px" %)**IN_4**|(% style="width:1112px" %)Discrete input #4 “dry contact” (+5V)129 -|(% style="width:100px" %)**5**| (% style="width:310px" %)**GND_4**|(% style="width:1112px" %)Discrete input #4 “dry contact” (ground)130 -|(% style="width:100px" %)**12**| (% style="width:310px" %)**OUT_4**|(% style="width:1112px" %)Discrete output #4 (+5V, 20mA)131 -|(% style="width:100px" %)**4**| (% style="width:310px" %)**GND_OUT_4**|(% style="width:1112px" %)Discrete output #4 (ground)132 -|(% style="width:100px" %)**11**| (% style="width:310px" %)**OUT_3**|(% style="width:1112px" %)Discrete output #3 (+5V, 20mA)133 -|(% style="width:100px" %)**3**| (% style="width:310px" %)**GND_OUT_3**|(% style="width:1112px" %)Discrete output #3 (ground)134 -|(% style="width:100px" %)**10**| (% style="width:310px" %)**OUT_2**|(% style="width:1112px" %)Discrete output #2 (+5V, 20mA)135 -|(% style="width:100px" %)**2**| (% style="width:310px" %)**GND_OUT_2**|(% style="width:1112px" %)Discrete output #2 (ground)136 -|(% style="width:100px" %)**9**| (% style="width:310px" %)**OUT_1**|(% style="width:1112px" %)Discrete output #1 (+5V, 20mA)137 -|(% style="width:100px" %)**1**| (% style="width:310px" %)**GND_OUT_1**|(% style="width:1112px" %)Discrete output #1 (ground)121 +|(% style="width:100px" %)**Pin**|**Name**|**Description** 122 +|(% style="width:100px" %)**16**|**IN_1**|Discrete input #1 “dry contact” (+5V) 123 +|(% style="width:100px" %)**8**|**GND_1**|Discrete input #1 “dry contact” (ground) 124 +|(% style="width:100px" %)**15**|**IN_2**|Discrete input #2 “dry contact” (+5V) 125 +|(% style="width:100px" %)**7**|**GND_2**|Discrete input #2 “dry contact” (ground) 126 +|(% style="width:100px" %)**14**|**IN_3**|Discrete input #3 “dry contact” (+5V) 127 +|(% style="width:100px" %)**6**|**GND_3**|Discrete input #3 “dry contact” (ground) 128 +|(% style="width:100px" %)**13**|**IN_4**|Discrete input #4 “dry contact” (+5V) 129 +|(% style="width:100px" %)**5**|**GND_4**|Discrete input #4 “dry contact” (ground) 130 +|(% style="width:100px" %)**12**|**OUT_4**|Discrete output #4 (+5V, 20mA) 131 +|(% style="width:100px" %)**4**|**GND_OUT_4**|Discrete output #4 (ground) 132 +|(% style="width:100px" %)**11**|**OUT_3**|Discrete output #3 (+5V, 20mA) 133 +|(% style="width:100px" %)**3**|**GND_OUT_3**|Discrete output #3 (ground) 134 +|(% style="width:100px" %)**10**|**OUT_2**|Discrete output #2 (+5V, 20mA) 135 +|(% style="width:100px" %)**2**|**GND_OUT_2**|Discrete output #2 (ground) 136 +|(% style="width:100px" %)**9**|**OUT_1**|Discrete output #1 (+5V, 20mA) 137 +|(% style="width:100px" %)**1**|**GND_OUT_1**|Discrete output #1 (ground) 138 138 139 139 = Indicators = 140 140