Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,25 +2,25 @@ 2 2 3 3 The BMS Main 2.1 headers are shown in figure below. 4 4 5 -[[The BMS Main 2.1 headers>>image:17315163 93377-928.jpeg||height="430" width="428"]]5 +[[The BMS Main 2.1 headers>>image:1731517946345-632.png||height="417" width="451"]] 6 6 7 7 === P1 – header for power supply === 8 8 9 9 [[image:1731516593096-166.png||data-xwiki-image-style-alignment="center"]] 10 10 11 -| (% style="width:100px" %)**Pin**|(% style="width:502px" %)**Name**|**Description**12 -| (% style="width:100px" %)**1**|(% style="width:502px" %)**GND**|Ground13 -| (% style="width:100px" %)**2**|(% style="width:502px" %)**V+**|Supply voltage 9-30V11 +|**Pin**|**Name**|**Description** 12 +|**1**|**GND**|Ground 13 +|**2**|**V+**|Supply voltage 9-30V 14 14 15 15 === P15 – header for BMS Logic === 16 16 17 17 [[image:1731516577472-301.png||data-xwiki-image-style-alignment="center"]] 18 18 19 -| (% style="width:100px" %)**Pin**|(% style="width:290px" %)**Name**|**Description**20 -| (% style="width:100px" %)**1**|(% style="width:290px" %)**RS485_A**|RS-485 line A for communication with BMS Logic21 -| (% style="width:100px" %)**2**|(% style="width:290px" %)**RS485_B**|RS-485 line B for communication with BMS Logic22 -| (% style="width:100px" %)**3**|(% style="width:290px" %)**+5V**|Supply voltage for BMS Logic23 -| (% style="width:100px" %)**4**|(% style="width:290px" %)**GND**|Ground19 +|**Pin**|**Name**|**Description** 20 +|**1**|**RS485_A**|RS-485 line A for communication with BMS Logic 21 +|**2**|**RS485_B**|RS-485 line B for communication with BMS Logic 22 +|**3**|**+5V**|Supply voltage for BMS Logic 23 +|**4**|**GND**|Ground 24 24 25 25 === P12 – header for current sensor === 26 26 ... ... @@ -78,9 +78,9 @@ 78 78 79 79 By default, relay 4 is used to control the heater. 80 80 81 - |**Pin**|**Name**|**Description**82 - |**1**|**V+**|Switching voltage (up to 55V, max 8A)83 - |**2**|**NO**|Normally open contact81 +**Pin**|**Name**|**Description** 82 +**1**|**V+**|Switching voltage (up to 55V, max 8A) 83 +**2**|**NO**|Normally open contact 84 84 85 85 === P14 – header for CAN and RS-485 interfaces === 86 86 ... ... @@ -169,10 +169,11 @@ 169 169 170 170 === DS8 – relay 2 indicator === 171 171 172 -|**State**|**Description** 173 -|**Lights green**|Relay #2 is closed 174 -|**Off**|Relay #2 is opened 175 175 173 +|**State**|(% style="width:183px" %)**Description** 174 +|**Lights green**|(% style="width:183px" %)Relay #2 is closed 175 +|**Off**|(% style="width:183px" %)Relay #2 is opened 176 + 176 176 === DS5 – relay 3 indicator === 177 177 178 178 |**State**|**Description**
- 1731517946345-632.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.3 KB - Content