Last modified by Admin on 2025/03/18 13:04

From version 6.1
edited by Admin
on 2025/02/20 12:05
Change comment: Загрузить новое вложение 1740053112487-862.png
To version 10.1
edited by Admin
on 2025/02/20 12:57
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -19,7 +19,6 @@
19 19  )))|125 × 84 × 25
20 20  |Mounting dimensions (length × width), mm|115 × 50
21 21  |Mounting holes|M4
22 -|Headers X1-X3 type|Molex series Mini-Fit
23 23  
24 24  == Headers ==
25 25  
... ... @@ -33,8 +33,21 @@
33 33  All headers are shown from the device side!
34 34  )))
35 35  
36 -=== X1 – header for cells and temperature sensors[[image:1733148735564-962.png||data-xwiki-image-style-alignment="center" height="84" width="218"]] ===
35 +=== X1 – header for cells and temperature sensors ===
37 37  
37 +(% class="wikigeneratedid" %)
38 +Receptacle Housing: Molex 39012160. Terminals: Molex 5556
39 +
40 +
41 +
42 +
43 +
44 +
45 +
46 +
47 +(% class="wikigeneratedid" %)
48 +[[image:1740053130023-265.png||data-xwiki-image-style-alignment="center"]]
49 +
38 38  |**Pin**|**Name**|**Description**
39 39  |**1**|**TEMP2**|Signal from the thermistor #2
40 40  |**2**|**TEMPC**|Ground of the thermistors
... ... @@ -55,8 +55,10 @@
55 55  
56 56  === X2, X3 – headers for communication with BMS Main ===
57 57  
58 -[[image:1733148758240-550.jpeg||data-xwiki-image-style-alignment="center" height="86" width="344"]]
70 +Receptacle Housing: Molex 39012040. Terminals: Molex 5556
59 59  
72 +[[image:1740053153731-112.png||data-xwiki-image-style-alignment="center"]]
73 +
60 60  |**Pin**|**Name**|**Description**
61 61  |**1**|**RS485_A**|RS-485 line A for communication with the BMS Main
62 62  |**2**|**RS485_B**|RS-485 line B for communication with the BMS Main
1740053130023-265.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +5.0 KB
Content
1740053153731-112.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +1.9 KB
Content