... ... @@ -88,12 +88,14 @@
88 88  1. Connect the BMS Logic 2.0 to each other (X2 -> X3).
89 89  1. Install jumper P1 on the last BMS Logic 2.0 in the chain.
90 90  
91 -Recommendations:
91 +(% class="box infomessage" %)
92 +(((
93 +**Recommendations:**
94 +~1. The total cable length (the sum of the lengths of all cables) between the BMS Main and the last BMS Logic 2.0 should not exceed 500 meters.
95 +2. Make all connections with the same cable.
96 +3. For a total cable length of more than 10 meters use twisted pair with the 120 Ohm wave impedance.
97 +)))
92 92  
93 -1. The total cable length (the sum of the lengths of all cables) between the BMS Main and the last BMS Logic 2.0 should not exceed 500 meters.
94 -1. Make all connections with the same cable.
95 -1. For a total cable length of more than 10 meters use twisted pair with the 120 Ohm wave impedance.
96 -
97 97  === 2.4.2 Connecting battery cells ===
98 98  
99 99  To connect the battery cells, follow the picture below. Incorrect connection of the cells can damage the BMS Logic 2.0.