Last modified by Admin on 2025/03/18 13:04

From version 3.1
edited by Admin
on 2024/12/02 14:57
Change comment: There is no comment for this version
To version 1.1
edited by Admin
on 2024/12/02 14:40
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,7 +11,7 @@
11 11  [[image:1733150108388-179.png||data-xwiki-image-style-alignment="center" height="384" width="555"]]
12 12  
13 13  |**Parameter**|**Value**
14 -|(((
14 +| (((
15 15  Overall dimensions (length × width × height), mm
16 16  )))|214 × 140 × 16
17 17  |Mounting dimensions (length × width), mm|198 × 132
... ... @@ -20,6 +20,14 @@
20 20  
21 21  == (% style="color:#333333" %)2.2 (%%)Headers ==
22 22  
23 +
24 +
25 +
26 +
27 +
28 +
29 +== ==
30 +
23 23  The BMS Logic 18 is designed to measure temperature and voltage of 18 battery cells.
24 24  
25 25  [[image:1733150257403-684.png||data-xwiki-image-style-alignment="center" height="376" width="640"]]
... ... @@ -26,7 +26,7 @@
26 26  
27 27  === 2.2.1 X1 – header for cells ===
28 28  
29 -[[image:1733150257406-647.jpeg||data-xwiki-image-style-alignment="center" height="73" width="256"]]
37 +[[image:1733150257406-647.jpeg||data-xwiki-image-style-alignment="center" height="76" width="268"]]
30 30  
31 31  |**Pin**|**Name**|**Description**
32 32  |**1**|**V-**|Minus of the cell stack
... ... @@ -50,9 +50,9 @@
50 50  |**19**|**C15**|Cell #15
51 51  |**20**|**C17**|Cell #17
52 52  
53 -=== 2.2.2 X2 – header 1 for temperature sensors ===
61 +=== X2 – header 1 for temperature sensors ===
54 54  
55 -[[image:1733150257408-172.jpeg||data-xwiki-image-style-alignment="center" height="81" width="267"]]
63 +[[image:1733150257408-172.jpeg||data-xwiki-image-style-alignment="center"]]
56 56  
57 57  |**Pin**|**Name**|**Description**
58 58  |**1**|**TEMPG9**|Ground of the thermistor #9
... ... @@ -74,10 +74,14 @@
74 74  |**17**|**TEMP2**|Signal from the thermistor #2
75 75  |**18**|**TEMP1**|Signal from the thermistor #1
76 76  
77 -== 2.2.3 X3 – header 2 for temperature sensors ==
78 78  
79 -[[image:1733150257410-796.jpeg||data-xwiki-image-style-alignment="center" height="81" width="268"]]
86 +1.
87 +11.
88 +111. X3 – header 2 for temperature sensors
80 80  
90 +
91 +[[image:1733150257410-796.jpeg]]
92 +
81 81  |**Pin**|**Name**|**Description**
82 82  |**1**|**TEMPG18**|Ground of the thermistor #18
83 83  |**2**|**TEMPG17**|Ground of the thermistor #17
... ... @@ -98,10 +98,13 @@
98 98  |**17**|**TEMP11**|Signal from the thermistor #11
99 99  |**18**|**TEMP10**|Signal from the thermistor #10
100 100  
101 -=== 2.3.4 X4, X5 – headers for communication with BMS Main ===
102 102  
103 -[[image:1733150513230-598.png||data-xwiki-image-style-alignment="center" height="89" width="81"]]
114 +1.
115 +11.
116 +111. X4, X5 – headers for communication with BMS Main
104 104  
118 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image005.emz]]
119 +
105 105  |**Pin**|**Name**|**Description**
106 106  |**1**|**RS485_A**|RS-485 line A for communication with the BMS Main
107 107  |**2**|**RS485_B**|RS-485 line B for communication with the BMS Main
... ... @@ -108,9 +108,10 @@
108 108  |**3**|**+5V**|Supply voltage 5V
109 109  |**4**|**GND**|Ground
110 110  
111 -== 2.4 Switches and Indicators ==
112 112  
113 -=== 2.4.1 SWD1 – address switch ===
127 +1.
128 +11.
129 +111. SWD1 – address switch
114 114  
115 115  |**Switch number**|**Description**
116 116  |**1**|The first (the lowest) bit of the address. Position ON - bit is 1
... ... @@ -119,60 +119,27 @@
119 119  |**4**|The fourth bit of the address. Position ON - bit is 1
120 120  |**5**|The fifth (the highest) bit of the address. Position ON - bit is 1
121 121  
122 -(% class="box infomessage" %)
123 -(((
124 -**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 18. The device address must be configured in the settings (see the section 4.2 Configuration procedure).
125 -)))
126 126  
127 -=== 2.4.2 SWD2 RS-485 termination resistor switch ===
139 +**Note There is no SWD1 switch in the recent revisions of the BMS Logic 18. The device address must be configured in the settings **(see the section 4.2 Configuration procedure).
128 128  
141 +
142 +1.
143 +11.
144 +111. SWD2 – RS-485 termination resistor switch
145 +
129 129  To connect the termination resistor between the **RS485_A** and **RS485_B** lines, switch SWD2 to the ON position.
130 130  
131 -(% class="box infomessage" %)
132 -(((
133 -**Note: **There is no SWD2 switch in the recent revisions of the BMS Logic 18. Connect a 120 Ohm termination resistor directly to the X5 connector between the lines RS485_A and RS485_B.
134 -)))
135 135  
136 -=== 2.4.3 DS1 mode indicator ===
149 +**Note There is no SWD2 switch in the recent revisions of the BMS Logic 18. Connect a 120 Ohm termination resistor directly to the X5 connector between the lines RS485_A and RS485_B.**
137 137  
151 +
152 +1.
153 +11.
154 +111. DS1 – mode indicator
155 +
138 138  |**State**|**Description**
139 139  |**Blinking**|Connection between the BMS Main and the device is established
140 140  |**Short flashing (~~50 milliseconds in a second)**|The device is measuring voltage and temperature. No communication between the BMS Main and the device
141 141  |**Long flashing (1 second in a 2 second period)**|The device is in the bootloader mode
142 142  
143 -== 2.5 Connection procedure ==
144 -
145 -=== 2.5.1 Connection to BMS Main ===
146 -
147 -To connect the BMS Main to BMS Logic 18 do the following steps:
148 -
149 -1. Connect the BMS Main to the first BMS Logic 18 (P15 -> X4);
150 -1. Connect the BMS Logic 18 to each other (X5 -> X4);
151 -1. Switch SWD2 on the last BMS Logic 18 to the ON position or connect a 120 Ohm termination resistor directly to the X5 connector of the last BMS Logic 18.
152 -
153 -(% class="box infomessage" %)
154 -(((
155 -**Recommendations:**
156 -~1. The total cable length (the sum of the lengths of all cables) between the BMS Main and the last BMS Logic 18 should not exceed 500 meters.
157 -2. Make all connections with the same cable.
158 -3. For a total cable length of more than 10 meters use twisted pair with the 120 Ohm wave impedance.
159 -)))
160 -
161 -=== 2.5.2 Connecting battery cells ===
162 -
163 -To connect the battery cells, follow figure below. Incorrect connection of the cells can damage the BMS Logic 18.
164 -
165 -Begin the connection with the negative of the battery: the "V-" of the first BMS Logic 18 is connected to "B-", then the first cell (C1) of the battery is connected, then the second (C2), etc. The “V-“ of the next BMS Logic 18 is connected to the C18 of the previous BMS Logic 18. If not all inputs of the cells are used, then the remaining inputs are connected to the cell with the most potential.
166 -
167 -
168 -[[image:1733151263524-832.jpeg||data-xwiki-image-style-alignment="center" height="492" width="612"]]
169 -
170 -(% class="box warningmessage" %)
171 -(((
172 -**Attention!**
173 -Connect the battery according to the diagram, otherwise the device may be damaged!
174 -)))
175 -
176 -=== 2.5.3 Connecting thermistors ===
177 -
178 -Thermistors should be fastened to the cells, excluding short circuits to the cell terminals (for example, isolate thermistors with heat shrink). For reliable operation, it is recommended to use all thermistors (a temperature sensor per cell).
161 +
1733150486376-819.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -1.5 KB
Content
1733150513230-598.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -1.7 KB
Content
1733151263524-832.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -114.2 KB
Content