Last modified by Admin on 2025/03/18 13:04

From version 20.1
edited by Admin
on 2025/03/18 12:51
Change comment: There is no comment for this version
To version 15.1
edited by Admin
on 2025/01/13 12:38
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,19 +1,8 @@
1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Installation and connection =
3 3  
4 -== ​​​​​Safety rules ==
4 +== ​​​​​Installation procedure ==
5 5  
6 -Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.
7 -
8 -It is not recommended to use the system in batteries formed by several series of cells connected in parallel. To increase capacity, it is recommended to connect several cells in parallel groups, and then connect the groups in series.
9 -
10 -(% class="box errormessage" %)
11 -(((
12 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
13 -)))
14 -
15 -== Installation procedure ==
16 -
17 17  The mounting area of the BMS Logic 18 must be protected from mechanical particles (dust, dirt, large objects) and water. The BMS Logic 18 is recommended to be placed close to the cells it controls, but away from high current circuits to reduce interference to measuring circuits and increase overall reliability of installation.
18 18  
19 19  The installation site must provide convenient access for subsequent connection to the device’s headers.
... ... @@ -30,6 +30,7 @@
30 30  )))|214 × 140 × 16
31 31  |Mounting dimensions (length × width), mm|198 × 132
32 32  |Mounting holes|M4
22 +|Headers X1-X5 type|Molex series Micro-Fit
33 33  
34 34  == Headers ==
35 35  
... ... @@ -45,8 +45,6 @@
45 45  
46 46  === X1 – header for cells ===
47 47  
48 -Receptacle Housing: Molex 430252000. Terminals: Molex 43030
49 -
50 50  [[image:1733150257406-647.jpeg||data-xwiki-image-style-alignment="center" height="73" width="256"]]
51 51  
52 52  |**Pin**|**Name**|**Description**
... ... @@ -73,8 +73,6 @@
73 73  
74 74  === X2 – header 1 for temperature sensors ===
75 75  
76 -Receptacle Housing: Molex 430251800. Terminals: Molex 43030
77 -
78 78  [[image:1733150257408-172.jpeg||data-xwiki-image-style-alignment="center" height="81" width="267"]]
79 79  
80 80  |**Pin**|**Name**|**Description**
... ... @@ -99,8 +99,6 @@
99 99  
100 100  === X3 – header 2 for temperature sensors ===
101 101  
102 -Receptacle Housing: Molex 430251800. Terminals: Molex 43030
103 -
104 104  [[image:1733150257410-796.jpeg||data-xwiki-image-style-alignment="center" height="81" width="268"]]
105 105  
106 106  |**Pin**|**Name**|**Description**
... ... @@ -125,8 +125,6 @@
125 125  
126 126  === X4, X5 – headers for communication with BMS Main ===
127 127  
128 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
129 -
130 130  [[image:1733150513230-598.png||data-xwiki-image-style-alignment="center" height="89" width="81"]]
131 131  
132 132  |**Pin**|**Name**|**Description**