Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 13:04
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS Logic 18.WebHome1 +drafts.BMS Logic 18.WebHome - Content
-
... ... @@ -1,8 +1,5 @@ 1 -(% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Installation and connection = 1 +== 2.1 Installation procedure == 3 3 4 -== Installation procedure == 5 - 6 6 The mounting area of the BMS Logic 18 must be protected from mechanical particles (dust, dirt, large objects) and water. The BMS Logic 18 is recommended to be placed close to the cells it controls, but away from high current circuits to reduce interference to measuring circuits and increase overall reliability of installation. 7 7 8 8 The installation site must provide convenient access for subsequent connection to the device’s headers. ... ... @@ -11,7 +11,7 @@ 11 11 12 12 Overall and mounting dimensions of the BMS Logic 18 are shown below. 13 13 14 -[[image:173 6771889450-259.png||data-xwiki-image-style-alignment="center" height="405" width="600"]]11 +[[image:1733150108388-179.png||data-xwiki-image-style-alignment="center" height="384" width="555"]] 15 15 16 16 |**Parameter**|**Value** 17 17 |((( ... ... @@ -21,11 +21,11 @@ 21 21 |Mounting holes|M4 22 22 |Headers X1-X5 type|Molex series Micro-Fit 23 23 24 -== Headers == 21 +== (% style="color:#333333" %)2.2 (%%)Headers == 25 25 26 26 The BMS Logic 18 is designed to measure temperature and voltage of 18 battery cells. 27 27 28 -[[image:173 6770801015-488.png||data-xwiki-image-style-alignment="center" height="350" width="600"]]25 +[[image:1733150257403-684.png||data-xwiki-image-style-alignment="center" height="376" width="640"]] 29 29 30 30 (% class="box warningmessage" %) 31 31 ((( ... ... @@ -33,10 +33,8 @@ 33 33 All headers are shown from the device side! 34 34 ))) 35 35 36 -=== X1 – header for cells === 33 +=== 2.2.1 X1 – header for cells === 37 37 38 -Receptacle Housing: Molex 430252000. Terminals: Molex 43030 39 - 40 40 [[image:1733150257406-647.jpeg||data-xwiki-image-style-alignment="center" height="73" width="256"]] 41 41 42 42 |**Pin**|**Name**|**Description** ... ... @@ -61,10 +61,8 @@ 61 61 |**19**|**C15**|Cell #15 62 62 |**20**|**C17**|Cell #17 63 63 64 -=== X2 – header 1 for temperature sensors === 59 +=== 2.2.2 X2 – header 1 for temperature sensors === 65 65 66 -Receptacle Housing: Molex 430251800. Terminals: Molex 43030 67 - 68 68 [[image:1733150257408-172.jpeg||data-xwiki-image-style-alignment="center" height="81" width="267"]] 69 69 70 70 |**Pin**|**Name**|**Description** ... ... @@ -87,10 +87,8 @@ 87 87 |**17**|**TEMP2**|Signal from the thermistor #2 88 88 |**18**|**TEMP1**|Signal from the thermistor #1 89 89 90 -== =X3 – header 2 for temperature sensors ===83 +== 2.2.3 X3 – header 2 for temperature sensors == 91 91 92 -Receptacle Housing: Molex 430251800. Terminals: Molex 43030 93 - 94 94 [[image:1733150257410-796.jpeg||data-xwiki-image-style-alignment="center" height="81" width="268"]] 95 95 96 96 |**Pin**|**Name**|**Description** ... ... @@ -113,10 +113,8 @@ 113 113 |**17**|**TEMP11**|Signal from the thermistor #11 114 114 |**18**|**TEMP10**|Signal from the thermistor #10 115 115 116 -=== X4, X5 – headers for communication with BMS Main === 107 +=== 2.3.4 X4, X5 – headers for communication with BMS Main === 117 117 118 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030 119 - 120 120 [[image:1733150513230-598.png||data-xwiki-image-style-alignment="center" height="89" width="81"]] 121 121 122 122 |**Pin**|**Name**|**Description** ... ... @@ -125,9 +125,9 @@ 125 125 |**3**|**+5V**|Supply voltage 5V 126 126 |**4**|**GND**|Ground 127 127 128 -== Switches and Indicators == 117 +== 2.4 Switches and Indicators == 129 129 130 -=== SWD1 – address switch === 119 +=== 2.4.1 SWD1 – address switch === 131 131 132 132 |**Switch number**|**Description** 133 133 |**1**|The first (the lowest) bit of the address. Position ON - bit is 1 ... ... @@ -138,10 +138,10 @@ 138 138 139 139 (% class="box infomessage" %) 140 140 ((( 141 -**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 18. The device address must be configured in the settings (see the section [[3. Configuration>>doc: Battery managementystems.BMS Logic 18.3\. Configuration.WebHome]]).130 +**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 18. The device address must be configured in the settings (see the section [[3. Configuration>>doc:drafts.BMS Logic 18.3\. Configuration.WebHome]]). 142 142 ))) 143 143 144 -=== SWD2 – RS-485 termination resistor switch === 133 +=== 2.4.2 SWD2 – RS-485 termination resistor switch === 145 145 146 146 To connect the termination resistor between the **RS485_A** and **RS485_B** lines, switch SWD2 to the ON position. 147 147 ... ... @@ -150,7 +150,7 @@ 150 150 **Note: **There is no SWD2 switch in the recent revisions of the BMS Logic 18. Connect a 120 Ohm termination resistor directly to the X5 connector between the lines RS485_A and RS485_B. 151 151 ))) 152 152 153 -=== DS1 – mode indicator === 142 +=== 2.4.3 DS1 – mode indicator === 154 154 155 155 (% style="width:551px" %) 156 156 |(% style="width:188px" %)**State**|(% style="width:362px" %)**Description** ... ... @@ -158,9 +158,9 @@ 158 158 |(% style="width:188px" %)**Short flashing (~~50 milliseconds in a second)**|(% style="width:362px" %)The device is measuring voltage and temperature. No communication between the BMS Main and the device 159 159 |(% style="width:188px" %)**Long flashing (1 second in a 2 second period)**|(% style="width:362px" %)The device is in the bootloader mode 160 160 161 -== Connection procedure == 150 +== 2.5 Connection procedure == 162 162 163 -=== Connection to BMS Main === 152 +=== 2.5.1 Connection to BMS Main === 164 164 165 165 To connect the BMS Main to BMS Logic 18 do the following steps: 166 166 ... ... @@ -176,7 +176,7 @@ 176 176 3. For a total cable length of more than 10 meters use twisted pair with the 120 Ohm wave impedance. 177 177 ))) 178 178 179 -=== Connecting battery cells === 168 +=== 2.5.2 Connecting battery cells === 180 180 181 181 To connect the battery cells, follow figure below. Incorrect connection of the cells can damage the BMS Logic 18. 182 182 ... ... @@ -191,7 +191,7 @@ 191 191 Connect the battery according to the diagram, otherwise the device may be damaged! 192 192 ))) 193 193 194 -=== Connecting thermistors === 183 +=== 2.5.3 Connecting thermistors === 195 195 196 196 Thermistors should be fastened to the cells, excluding short circuits to the cell terminals (for example, isolate thermistors with heat shrink). For reliable operation, it is recommended to use all thermistors (a temperature sensor per cell). 197 197
- 1736770801015-488.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -26.0 KB - Content
- 1736771889450-259.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -36.9 KB - Content