Summary

Details

Page properties
Content
... ... @@ -1,8 +1,19 @@
1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Installation and connection =
3 3  
4 -== ​​​​​Installation procedure ==
4 +== ​​​​​Safety rules ==
5 5  
6 +Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.
7 +
8 +It is not recommended to use the system in batteries formed by several series of cells connected in parallel. To increase capacity, it is recommended to connect several cells in parallel groups, and then connect the groups in series.
9 +
10 +(% class="box warningmessage" %)
11 +(((
12 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
13 +)))
14 +
15 +== Installation procedure ==
16 +
6 6  The mounting area of the BMS Logic 18 must be protected from mechanical particles (dust, dirt, large objects) and water. The BMS Logic 18 is recommended to be placed close to the cells it controls, but away from high current circuits to reduce interference to measuring circuits and increase overall reliability of installation.
7 7  
8 8  The installation site must provide convenient access for subsequent connection to the device’s headers.
... ... @@ -19,7 +19,6 @@
19 19  )))|214 × 140 × 16
20 20  |Mounting dimensions (length × width), mm|198 × 132
21 21  |Mounting holes|M4
22 -|Headers X1-X5 type|Molex series Micro-Fit
23 23  
24 24  == Headers ==
25 25  
... ... @@ -35,6 +35,8 @@
35 35  
36 36  === X1 – header for cells ===
37 37  
48 +Receptacle Housing: Molex 430252000. Terminals: Molex 43030
49 +
38 38  [[image:1733150257406-647.jpeg||data-xwiki-image-style-alignment="center" height="73" width="256"]]
39 39  
40 40  |**Pin**|**Name**|**Description**
... ... @@ -61,6 +61,8 @@
61 61  
62 62  === X2 – header 1 for temperature sensors ===
63 63  
76 +Receptacle Housing: Molex 430251800. Terminals: Molex 43030
77 +
64 64  [[image:1733150257408-172.jpeg||data-xwiki-image-style-alignment="center" height="81" width="267"]]
65 65  
66 66  |**Pin**|**Name**|**Description**
... ... @@ -85,6 +85,8 @@
85 85  
86 86  === X3 – header 2 for temperature sensors ===
87 87  
102 +Receptacle Housing: Molex 430251800. Terminals: Molex 43030
103 +
88 88  [[image:1733150257410-796.jpeg||data-xwiki-image-style-alignment="center" height="81" width="268"]]
89 89  
90 90  |**Pin**|**Name**|**Description**
... ... @@ -109,6 +109,8 @@
109 109  
110 110  === X4, X5 – headers for communication with BMS Main ===
111 111  
128 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
129 +
112 112  [[image:1733150513230-598.png||data-xwiki-image-style-alignment="center" height="89" width="81"]]
113 113  