Last modified by Admin on 2025/03/18 13:04

From version 10.2
edited by Admin
on 2024/12/11 11:20
Change comment: Update document after refactoring.
To version 17.1
edited by Admin
on 2025/02/20 12:51
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,7 +11,7 @@
11 11  
12 12  Overall and mounting dimensions of the BMS Logic 18 are shown below.
13 13  
14 -[[image:1733150108388-179.png||data-xwiki-image-style-alignment="center" height="384" width="555"]]
14 +[[image:1736771889450-259.png||data-xwiki-image-style-alignment="center" height="405" width="600"]]
15 15  
16 16  |**Parameter**|**Value**
17 17  |(((
... ... @@ -19,13 +19,12 @@
19 19  )))|214 × 140 × 16
20 20  |Mounting dimensions (length × width), mm|198 × 132
21 21  |Mounting holes|M4
22 -|Headers X1-X5 type|Molex series Micro-Fit
23 23  
24 24  == Headers ==
25 25  
26 26  The BMS Logic 18 is designed to measure temperature and voltage of 18 battery cells.
27 27  
28 -[[image:1733150257403-684.png||data-xwiki-image-style-alignment="center" height="376" width="640"]]
27 +[[image:1736770801015-488.png||data-xwiki-image-style-alignment="center" height="350" width="600"]]
29 29  
30 30  (% class="box warningmessage" %)
31 31  (((
... ... @@ -35,6 +35,8 @@
35 35  
36 36  === X1 – header for cells ===
37 37  
37 +Receptacle Housing: Molex 430252000. Terminals: Molex 43030
38 +
38 38  [[image:1733150257406-647.jpeg||data-xwiki-image-style-alignment="center" height="73" width="256"]]
39 39  
40 40  |**Pin**|**Name**|**Description**
... ... @@ -61,6 +61,8 @@
61 61  
62 62  === X2 – header 1 for temperature sensors ===
63 63  
65 +Receptacle Housing: Molex 430251800. Terminals: Molex 43030
66 +
64 64  [[image:1733150257408-172.jpeg||data-xwiki-image-style-alignment="center" height="81" width="267"]]
65 65  
66 66  |**Pin**|**Name**|**Description**
... ... @@ -85,6 +85,8 @@
85 85  
86 86  === X3 – header 2 for temperature sensors ===
87 87  
91 +Receptacle Housing: Molex 430251800. Terminals: Molex 43030
92 +
88 88  [[image:1733150257410-796.jpeg||data-xwiki-image-style-alignment="center" height="81" width="268"]]
89 89  
90 90  |**Pin**|**Name**|**Description**
... ... @@ -109,6 +109,8 @@
109 109  
110 110  === X4, X5 – headers for communication with BMS Main ===
111 111  
117 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
118 +
112 112  [[image:1733150513230-598.png||data-xwiki-image-style-alignment="center" height="89" width="81"]]
113 113  
114 114  |**Pin**|**Name**|**Description**
... ... @@ -130,7 +130,7 @@
130 130  
131 131  (% class="box infomessage" %)
132 132  (((
133 -**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 18. The device address must be configured in the settings (see the section [[3. Configuration>>doc:drafts.BMS Logic 18.3\. Configuration.WebHome]]).
140 +**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 18. The device address must be configured in the settings (see the section [[3. Configuration>>doc:Battery management systems.BMS Logic 18.3\. Configuration.WebHome]]).
134 134  )))
135 135  
136 136  === SWD2 – RS-485 termination resistor switch ===
1736770801015-488.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +26.0 KB
Content
1736771889450-259.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +36.9 KB
Content