Wiki source code of 1. Technical specifications

Last modified by Admin on 2025/05/28 17:26

Hide last authors
Admin 3.1 1 (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 = Technical specifications =
3
Admin 10.1 4 [[image:10-BMS-Logic-18.png||alt="Logic 18" data-xwiki-image-style-alignment="center" height="179" width="450"]]
Admin 1.1 5
6 BMS Logic 18 extends the second generation of measuring modules and provides the means to measure parameters up to 18 cells. It determines voltage and temperature of the battery cells and does passive balancing of the cells on a command from the BMS controller.
7
Admin 3.1 8 == Specifications ==
Admin 1.1 9
Admin 7.1 10 (% style="width:637px" %)
11 |(% style="width:473px" %)**Parameter**|(% style="width:160px" %)**Value**
12 |(% style="width:473px" %)Supply voltage, V|(% style="width:160px" %)5.0 ± 0.5
Admin 11.1 13 |(% style="width:473px" %)Current consumption @5 V, mA (maximum)|(% style="width:160px" %)10
Admin 11.2 14 |(% style="width:473px" %)Cell stack voltage, V|(% style="width:160px" %)16 to 78
Admin 11.1 15 |(% style="width:473px" %)Power consumption @Cell stack, mW (maximum)|(% style="width:160px" %)200
Admin 7.1 16 |(% style="width:473px" %)Number of cells|(% style="width:160px" %)6 to 18
17 |(% style="width:473px" %)Balancing current @4.2 V on a cell, mA (average)|(% style="width:160px" %)350
Admin 12.1 18 |(% style="width:473px" %)Cell voltage measurement error, V (maximum)|(% style="width:160px" %)± 0.004
19 |(% style="width:473px" %)Cell temperature measurement error, °С (maximum)|(% style="width:160px" %)± 2
Admin 7.1 20 |(% style="width:473px" %)Dimensions (length × width × height), mm|(% style="width:160px" %)214 × 140 × 16
Admin 11.1 21 |(% style="width:473px" %)Weight, g|(% style="width:160px" %)390 ± 20
Admin 7.1 22 |(% style="width:473px" %)Operating temperature range, ºС|(% style="width:160px" %)-40 to +85
23 |(% style="width:473px" %)Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|(% style="width:160px" %)3500
24 |Headers X1-X5 type|(% style="width:160px" %)Molex series Micro-Fit
Admin 1.1 25
Admin 3.1 26 == Overall and mounting dimensions ==
Admin 1.1 27
Admin 10.1 28 [[image:1746622186715-714.png||data-xwiki-image-style-alignment="center" height="383" width="450"]]
Admin 2.1 29
30