Summary

Details

Page properties
Content
... ... @@ -1,7 +1,7 @@
1 1  (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Technical specifications =
3 3  
4 -[[image:https://movicomelectric.com/wa-data/public/site/img/10-BMS-Logic-18-34.png||alt="Logic 18" data-xwiki-image-style-alignment="center" height="227" width="503"]]
4 +[[image:10-BMS-Logic-18.png||alt="Logic 18" data-xwiki-image-style-alignment="center" height="179" width="450"]]
5 5  
6 6  BMS Logic 18 extends the second generation of measuring modules and provides the means to measure parameters up to 18 cells. It determines voltage and temperature of the battery cells and does passive balancing of the cells on a command from the BMS controller.
7 7  
... ... @@ -10,15 +10,15 @@
10 10  (% style="width:637px" %)
11 11  |(% style="width:473px" %)**Parameter**|(% style="width:160px" %)**Value**
12 12  |(% style="width:473px" %)Supply voltage, V|(% style="width:160px" %)5.0 ± 0.5
13 -|(% style="width:473px" %)Current consumption @5 V, mA (typical)|(% style="width:160px" %)4
14 -|(% style="width:473px" %)Cell stack voltage, V|(% style="width:160px" %)10 to 80
15 -|(% style="width:473px" %)Power consumption @Cell stack, mW (maximum)|(% style="width:160px" %)175
13 +|(% style="width:473px" %)Current consumption @5 V, mA (maximum)|(% style="width:160px" %)10
14 +|(% style="width:473px" %)Cell stack voltage, V|(% style="width:160px" %)16 to 52
15 +|(% style="width:473px" %)Power consumption @Cell stack, mW (maximum)|(% style="width:160px" %)200
16 16  |(% style="width:473px" %)Number of cells|(% style="width:160px" %)6 to 18
17 17  |(% style="width:473px" %)Balancing current @4.2 V on a cell, mA (average)|(% style="width:160px" %)350
18 18  |(% style="width:473px" %)Cell voltage measurement error, V (maximum)|(% style="width:160px" %)±0.004
19 19  |(% style="width:473px" %)Cell temperature measurement error, °С (maximum)|(% style="width:160px" %)±2
20 20  |(% style="width:473px" %)Dimensions (length × width × height), mm|(% style="width:160px" %)214 × 140 × 16
21 -|(% style="width:473px" %)Weight, g|(% style="width:160px" %)380 ± 5
21 +|(% style="width:473px" %)Weight, g|(% style="width:160px" %)390 ± 20
22 22  |(% style="width:473px" %)Operating temperature range, ºС|(% style="width:160px" %)-40 to +85
23 23  |(% style="width:473px" %)Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|(% style="width:160px" %)3500
24 24  |Headers X1-X5 type|(% style="width:160px" %)Molex series Micro-Fit
... ... @@ -25,6 +25,6 @@
25 25  
26 26  == Overall and mounting dimensions ==
27 27  
28 -[[image:1736771831256-302.png||data-xwiki-image-style-alignment="center" height="473" width="600"]]
28 +[[image:1746622186715-714.png||data-xwiki-image-style-alignment="center" height="383" width="450"]]
29 29  
30 30