... ... @@ -7,21 +7,21 @@
7 7  
8 8  == Specifications ==
9 9  
10 -(% style="width:611.818px" %)
11 -|(% style="width:473px" %)**Parameter**|(% style="width:136px" %)**Value**
12 -|(% style="width:473px" %)Supply voltage, V|(% style="width:136px" %)5.0 ± 0.5
13 -|(% style="width:473px" %)Current consumption @5 V, mA (typical)|(% style="width:136px" %)4
14 -|(% style="width:473px" %)Cell stack voltage, V|(% style="width:136px" %)10 to 80
15 -|(% style="width:473px" %)Power consumption @Cell stack, mW (maximum)|(% style="width:136px" %)175
16 -|(% style="width:473px" %)Number of cells|(% style="width:136px" %)6 to 18
17 -|(% style="width:473px" %)Balancing current @4.2 V on a cell, mA (average)|(% style="width:136px" %)350
18 -|(% style="width:473px" %)Cell voltage measurement error, V (maximum)|(% style="width:136px" %)±0.004
19 -|(% style="width:473px" %)Cell temperature measurement error, °С (maximum)|(% style="width:136px" %)±2
20 -|(% style="width:473px" %)Dimensions (length × width × height), mm|(% style="width:136px" %)214 × 140 × 16
21 -|(% style="width:473px" %)Weight, g|(% style="width:136px" %)380 ± 5
22 -|(% style="width:473px" %)Operating temperature range, ºС|(% style="width:136px" %)-40 to +85
23 -|(% style="width:473px" %)Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|(% style="width:136px" %)3500
24 -|Headers X1-X5 type|Molex series Micro-Fit
10 +(% style="width:637px" %)
11 +|(% style="width:473px" %)**Parameter**|(% style="width:160px" %)**Value**
12 +|(% style="width:473px" %)Supply voltage, V|(% style="width:160px" %)5.0 ± 0.5
13 +|(% style="width:473px" %)Current consumption @5 V, mA (typical)|(% style="width:160px" %)4
14 +|(% style="width:473px" %)Cell stack voltage, V|(% style="width:160px" %)10 to 80
15 +|(% style="width:473px" %)Power consumption @Cell stack, mW (maximum)|(% style="width:160px" %)175
16 +|(% style="width:473px" %)Number of cells|(% style="width:160px" %)6 to 18
17 +|(% style="width:473px" %)Balancing current @4.2 V on a cell, mA (average)|(% style="width:160px" %)350
18 +|(% style="width:473px" %)Cell voltage measurement error, V (maximum)|(% style="width:160px" %)±0.004
19 +|(% style="width:473px" %)Cell temperature measurement error, °С (maximum)|(% style="width:160px" %)±2
20 +|(% style="width:473px" %)Dimensions (length × width × height), mm|(% style="width:160px" %)214 × 140 × 16
21 +|(% style="width:473px" %)Weight, g|(% style="width:160px" %)380 ± 5
22 +|(% style="width:473px" %)Operating temperature range, ºС|(% style="width:160px" %)-40 to +85
23 +|(% style="width:473px" %)Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|(% style="width:160px" %)3500
24 +|Headers X1-X5 type|(% style="width:160px" %)Molex series Micro-Fit
25 25  