Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/28 17:26
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7,21 +7,21 @@ 7 7 8 8 == Specifications == 9 9 10 -(% style="width:6 11.818px" %)11 -|(% style="width:473px" %)**Parameter**|(% style="width:1 36px" %)**Value**12 -|(% style="width:473px" %)Supply voltage, V|(% style="width:1 36px" %)5.0 ± 0.513 -|(% style="width:473px" %)Current consumption @5 V, mA (typical)|(% style="width:1 36px" %)414 -|(% style="width:473px" %)Cell stack voltage, V|(% style="width:1 36px" %)10 to 8015 -|(% style="width:473px" %)Power consumption @Cell stack, mW (maximum)|(% style="width:1 36px" %)17516 -|(% style="width:473px" %)Number of cells|(% style="width:1 36px" %)6 to 1817 -|(% style="width:473px" %)Balancing current @4.2 V on a cell, mA (average)|(% style="width:1 36px" %)35018 -|(% style="width:473px" %)Cell voltage measurement error, V (maximum)|(% style="width:1 36px" %)±0.00419 -|(% style="width:473px" %)Cell temperature measurement error, °С (maximum)|(% style="width:1 36px" %)±220 -|(% style="width:473px" %)Dimensions (length × width × height), mm|(% style="width:1 36px" %)214 × 140 × 1621 -|(% style="width:473px" %)Weight, g|(% style="width:1 36px" %)380 ± 522 -|(% style="width:473px" %)Operating temperature range, ºС|(% style="width:1 36px" %)-40 to +8523 -|(% style="width:473px" %)Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|(% style="width:1 36px" %)350024 -|Headers X1-X5 type|Molex series Micro-Fit 10 +(% style="width:637px" %) 11 +|(% style="width:473px" %)**Parameter**|(% style="width:160px" %)**Value** 12 +|(% style="width:473px" %)Supply voltage, V|(% style="width:160px" %)5.0 ± 0.5 13 +|(% style="width:473px" %)Current consumption @5 V, mA (typical)|(% style="width:160px" %)4 14 +|(% style="width:473px" %)Cell stack voltage, V|(% style="width:160px" %)10 to 80 15 +|(% style="width:473px" %)Power consumption @Cell stack, mW (maximum)|(% style="width:160px" %)175 16 +|(% style="width:473px" %)Number of cells|(% style="width:160px" %)6 to 18 17 +|(% style="width:473px" %)Balancing current @4.2 V on a cell, mA (average)|(% style="width:160px" %)350 18 +|(% style="width:473px" %)Cell voltage measurement error, V (maximum)|(% style="width:160px" %)±0.004 19 +|(% style="width:473px" %)Cell temperature measurement error, °С (maximum)|(% style="width:160px" %)±2 20 +|(% style="width:473px" %)Dimensions (length × width × height), mm|(% style="width:160px" %)214 × 140 × 16 21 +|(% style="width:473px" %)Weight, g|(% style="width:160px" %)380 ± 5 22 +|(% style="width:473px" %)Operating temperature range, ºС|(% style="width:160px" %)-40 to +85 23 +|(% style="width:473px" %)Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|(% style="width:160px" %)3500 24 +|Headers X1-X5 type|(% style="width:160px" %)Molex series Micro-Fit 25 25 26 26 == Overall and mounting dimensions == 27 27