... ... @@ -1,8 +1,5 @@
1 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 -= Configuration =
1 +== 3.1 Connecting device to PC ==
3 3  
4 -== Connecting device to PC ==
5 -
6 6  To connect the BMS Logic 12 to a PC, use the BMS USB-RS485 adapter. It allows to power and communicate with the BMS Logic 12:
7 7  
8 8  1. Connect the BMS USB-RS485 to the BMS Logic 12:
... ... @@ -13,9 +13,9 @@
13 13  
14 14  The assembly drawings of the harnesses between the BMS USB-RS485 and BMS Logic 12 are give below.
15 15  
16 -=== Communication and power cable ===
13 +=== 3.1.1 Communication and power cable ===
17 17  
18 -[[image:1733145551342-738.png||data-xwiki-image-style-alignment="center" height="225" width="410"]]
15 +[[image:1733145551342-738.png||data-xwiki-image-style-alignment="center" height="214" width="389"]]
19 19  
20 20  The wires of the communication and power cable must be connected according to the following table:
21 21  
... ... @@ -26,11 +26,11 @@
26 26  |**+5V**|(% style="width:149px" %)3|(% style="width:153px" %)3
27 27  |**GND**|(% style="width:149px" %)4|(% style="width:153px" %)4
28 28  
29 -=== Cells cable ===
26 +=== 3.1.2 Cells cable ===
30 30  
31 -[[image:1733146156957-806.png||data-xwiki-image-style-alignment="center" height="131" width="599"]]
28 +[[image:1733145551344-998.png||data-xwiki-image-style-alignment="center" height="100" width="456"]]
32 32  
33 -[[image:1733145551345-310.png||data-xwiki-image-style-alignment="center" height="199" width="389"]]
30 +[[image:1733145551345-310.png||data-xwiki-image-style-alignment="center" height="217" width="425"]]
34 34  
35 35  
36 36  The wires of the cells cable must be connected according to the following table:
... ... @@ -51,7 +51,7 @@
51 51  |**C11**|(% style="width:148px" %)9|(% style="width:149px" %)14
52 52  |**C12**|(% style="width:148px" %)10|(% style="width:149px" %)7
53 53  
54 -== Setting the device address ==
51 +=== 3.2 Setting the device address ===
55 55  
56 56  Launch the ElectricDeviceMonitor, then select the “BMS Logic 12/18 3.x” monitor:
57 57  
... ... @@ -58,16 +58,8 @@
58 58  [[image:1733145551346-396.png||data-xwiki-image-style-alignment="center" height="324" width="296"]]
59 59  
60 60  
61 -Set the following settings to connect to the BMS Logic 12:
58 +Select the following settings to connect to the BMS Logic 12: 115200 bps, 8 bits, no parity, 1 stop bit, device address 247. The address 247 is a service address that the device will always answer.
62 62  
63 -* 115200 bps,
64 -* 8 bits,
65 -* no parity,
66 -* 1 stop bit,
67 -* device address 247.
68 -
69 -The address 247 is a service address that the device will always answer.
70 -
71 71  [[image:1733145551347-494.png||data-xwiki-image-style-alignment="center" height="242" width="439"]]
72 72  
73 73  Check the connection with the BMS Logic 12 is established.
... ... @@ -74,6 +74,4 @@
74 74  
75 75  Set the needed device address and click the “Save” button:
76 76  
77 -[[image:1733145551348-226.png||data-xwiki-image-style-alignment="center" height="444" width="682"]]
78 -
79 -
66 +[[image:1733145551348-226.png||data-xwiki-image-style-alignment="center" height="464" width="712"]]
1733146156957-806.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -19.5 KB
Content
1733145551344-998.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +19.5 KB
Content