Changes for page 3. Configuration

Last modified by Admin on 2024/12/11 11:19

From version 3.1
edited by Admin
on 2024/12/02 13:27
Change comment: There is no comment for this version
To version 9.2
edited by Admin
on 2024/12/11 11:19
Change comment: Update document after refactoring.

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -drafts.BMS Logic 12.WebHome
1 +Battery management systems.BMS Logic 12.WebHome
Content
... ... @@ -1,5 +1,8 @@
1 -== 3.1 Connecting device to PC ==
1 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 += Configuration =
2 2  
4 +== Connecting device to PC ==
5 +
3 3  To connect the BMS Logic 12 to a PC, use the BMS USB-RS485 adapter. It allows to power and communicate with the BMS Logic 12:
4 4  
5 5  1. Connect the BMS USB-RS485 to the BMS Logic 12:
... ... @@ -10,9 +10,9 @@
10 10  
11 11  The assembly drawings of the harnesses between the BMS USB-RS485 and BMS Logic 12 are give below.
12 12  
13 -=== 3.1.1 Communication and power cable ===
16 +=== Communication and power cable ===
14 14  
15 -[[image:1733145551342-738.png||data-xwiki-image-style-alignment="center" height="206" width="375"]]
18 +[[image:1733145551342-738.png||data-xwiki-image-style-alignment="center" height="225" width="410"]]
16 16  
17 17  The wires of the communication and power cable must be connected according to the following table:
18 18  
... ... @@ -23,11 +23,11 @@
23 23  |**+5V**|(% style="width:149px" %)3|(% style="width:153px" %)3
24 24  |**GND**|(% style="width:149px" %)4|(% style="width:153px" %)4
25 25  
26 -=== 3.1.2 Cells cable ===
29 +=== Cells cable ===
27 27  
28 -[[image:1733145551344-998.png||data-xwiki-image-style-alignment="center" height="100" width="456"]]
31 +[[image:1733146156957-806.png||data-xwiki-image-style-alignment="center" height="131" width="599"]]
29 29  
30 -[[image:1733145551345-310.png||data-xwiki-image-style-alignment="center" height="217" width="425"]]
33 +[[image:1733145551345-310.png||data-xwiki-image-style-alignment="center" height="199" width="389"]]
31 31  
32 32  
33 33  The wires of the cells cable must be connected according to the following table:
... ... @@ -48,7 +48,7 @@
48 48  |**C11**|(% style="width:148px" %)9|(% style="width:149px" %)14
49 49  |**C12**|(% style="width:148px" %)10|(% style="width:149px" %)7
50 50  
51 -=== 3.2 Setting the device address ===
54 +== Setting the device address ==
52 52  
53 53  Launch the ElectricDeviceMonitor, then select the “BMS Logic 12/18 3.x” monitor:
54 54  
... ... @@ -72,3 +72,5 @@
72 72  Set the needed device address and click the “Save” button:
73 73  
74 74  [[image:1733145551348-226.png||data-xwiki-image-style-alignment="center" height="444" width="682"]]
78 +
79 +
1733145551344-998.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -19.5 KB
Content
1733146156957-806.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +19.5 KB
Content