Wiki source code of 3. Configuration
Last modified by Admin on 2024/12/11 11:19
Hide last authors
author | version | line-number | content |
---|---|---|---|
![]() |
9.1 | 1 | (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) |
2 | = Configuration = | ||
![]() |
1.1 | 3 | |
![]() |
9.1 | 4 | == Connecting device to PC == |
5 | |||
![]() |
1.1 | 6 | To connect the BMS Logic 12 to a PC, use the BMS USB-RS485 adapter. It allows to power and communicate with the BMS Logic 12: |
7 | |||
8 | 1. Connect the BMS USB-RS485 to the BMS Logic 12: | ||
9 | a) the communication circuits (X3 -> X3); | ||
10 | b) the circuits of cells (X5 -> X1). | ||
11 | 1. Connect the BMS USB-RS485 to a PC using a mini-USB or USB-C cable. | ||
12 | 1. Turn all the BMS USB-RS485’s switches to the “I” position. | ||
13 | |||
14 | The assembly drawings of the harnesses between the BMS USB-RS485 and BMS Logic 12 are give below. | ||
15 | |||
![]() |
9.1 | 16 | === Communication and power cable === |
![]() |
1.1 | 17 | |
![]() |
7.1 | 18 | [[image:1733145551342-738.png||data-xwiki-image-style-alignment="center" height="225" width="410"]] |
![]() |
1.1 | 19 | |
20 | The wires of the communication and power cable must be connected according to the following table: | ||
21 | |||
22 | (% style="width:398px" %) | ||
23 | |**Circuit name**|(% style="width:149px" %)**Pin of the connector to BMS USB-RS485**|(% style="width:153px" %)**Pin of the connector to BMS Logic 12** | ||
24 | |**RS485_A**|(% style="width:149px" %)1|(% style="width:153px" %)1 | ||
25 | |**RS485_B**|(% style="width:149px" %)2|(% style="width:153px" %)2 | ||
26 | |**+5V**|(% style="width:149px" %)3|(% style="width:153px" %)3 | ||
27 | |**GND**|(% style="width:149px" %)4|(% style="width:153px" %)4 | ||
28 | |||
![]() |
9.1 | 29 | === Cells cable === |
![]() |
1.1 | 30 | |
![]() |
7.1 | 31 | [[image:1733146156957-806.png||data-xwiki-image-style-alignment="center" height="131" width="599"]] |
![]() |
1.1 | 32 | |
![]() |
7.1 | 33 | [[image:1733145551345-310.png||data-xwiki-image-style-alignment="center" height="199" width="389"]] |
![]() |
1.1 | 34 | |
35 | |||
36 | The wires of the cells cable must be connected according to the following table: | ||
37 | |||
38 | (% style="width:393px" %) | ||
39 | |**Circuit name**|(% style="width:148px" %)**Pin of the connector to BMS USB-RS485**|(% style="width:149px" %)**Pin of the connector to BMS Logic 12** | ||
40 | |**V-**|(% style="width:148px" %)1|(% style="width:149px" %)1 | ||
41 | |**C1**|(% style="width:148px" %)13|(% style="width:149px" %)9 | ||
42 | |**C2**|(% style="width:148px" %)2|(% style="width:149px" %)2 | ||
43 | |**C3**|(% style="width:148px" %)14|(% style="width:149px" %)10 | ||
44 | |**C4**|(% style="width:148px" %)3|(% style="width:149px" %)3 | ||
45 | |**C5**|(% style="width:148px" %)15|(% style="width:149px" %)11 | ||
46 | |**C6**|(% style="width:148px" %)4|(% style="width:149px" %)4 | ||
47 | |**C7**|(% style="width:148px" %)5|(% style="width:149px" %)12 | ||
48 | |**C8**|(% style="width:148px" %)6|(% style="width:149px" %)5 | ||
49 | |**C9**|(% style="width:148px" %)7|(% style="width:149px" %)13 | ||
50 | |**C10**|(% style="width:148px" %)8|(% style="width:149px" %)6 | ||
51 | |**C11**|(% style="width:148px" %)9|(% style="width:149px" %)14 | ||
52 | |**C12**|(% style="width:148px" %)10|(% style="width:149px" %)7 | ||
53 | |||
![]() |
9.1 | 54 | == Setting the device address == |
![]() |
1.1 | 55 | |
56 | Launch the ElectricDeviceMonitor, then select the “BMS Logic 12/18 3.x” monitor: | ||
57 | |||
58 | [[image:1733145551346-396.png||data-xwiki-image-style-alignment="center" height="324" width="296"]] | ||
59 | |||
60 | |||
![]() |
2.1 | 61 | Set the following settings to connect to the BMS Logic 12: |
![]() |
1.1 | 62 | |
![]() |
2.1 | 63 | * 115200 bps, |
64 | * 8 bits, | ||
65 | * no parity, | ||
66 | * 1 stop bit, | ||
67 | * device address 247. | ||
68 | |||
69 | The address 247 is a service address that the device will always answer. | ||
70 | |||
![]() |
1.1 | 71 | [[image:1733145551347-494.png||data-xwiki-image-style-alignment="center" height="242" width="439"]] |
72 | |||
73 | Check the connection with the BMS Logic 12 is established. | ||
74 | |||
75 | Set the needed device address and click the “Save” button: | ||
76 | |||
![]() |
3.1 | 77 | [[image:1733145551348-226.png||data-xwiki-image-style-alignment="center" height="444" width="682"]] |
![]() |
5.1 | 78 | |
79 |