1 == 2.1 Installation procedure ==
2
3 The mounting area of the BMS Logic 12 must be protected from mechanical particles (dust, dirt, large objects) and water. The BMS Logic 12 is recommended to be placed close to the cells it controls, but away from high current circuits to reduce interference to measuring circuits and increase overall reliability of installation.
4
5 The installation site must provide convenient access for subsequent connection to the device’s headers.
6
7 The BMS Logic 12 has a heat sink to dissipate the heat generated during the balancing of the cells. When used in enclosed enclosures, heat must be removed from the sink, otherwise it may damage the device.
8
9 Overall and mounting dimensions of the BMS Logic 12 are shown below.
10
11 [[image:1733142832467-386.png||data-xwiki-image-style-alignment="center" height="410" width="486"]]
12
13
14
15 (% style="width:477px" %)
16 |**Parameter**|(% style="width:160px" %)**Value**
17 |Overall dimensions (length × width × height), mm|(% style="width:160px" %)139 × 126 × 16
18 |Mounting dimensions (length × width), mm|(% style="width:160px" %)123 × 118
19 |Mounting holes|(% style="width:160px" %)M4
20 |Headers X1-X4 type|(% style="width:160px" %)Molex series Micro-Fit
21
22
23 == 2.2 Headers description ==