Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 13:04
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Logic 12.WebHome1 +Battery management systems.BMS Logic 12.WebHome - Content
-
... ... @@ -1,5 +1,8 @@ 1 -== 2.1 Installation procedure == 1 +(% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += nstallation and connection = 2 2 4 +== Installation procedure == 5 + 3 3 The mounting area of the BMS Logic 12 must be protected from mechanical particles (dust, dirt, large objects) and water. The BMS Logic 12 is recommended to be placed close to the cells it controls, but away from high current circuits to reduce interference to measuring circuits and increase overall reliability of installation. 4 4 5 5 The installation site must provide convenient access for subsequent connection to the device’s headers. ... ... @@ -8,25 +8,30 @@ 8 8 9 9 Overall and mounting dimensions of the BMS Logic 12 are shown below. 10 10 11 -[[image:1733 142832467-386.png||data-xwiki-image-style-alignment="center" height="410" width="486"]]14 +[[image:1736773655076-566.png||data-xwiki-image-style-alignment="center" height="534" width="600"]] 12 12 13 - 14 - 15 15 (% style="width:477px" %) 16 16 |**Parameter**|(% style="width:160px" %)**Value** 17 17 |Overall dimensions (length × width × height), mm|(% style="width:160px" %)139 × 126 × 16 18 18 |Mounting dimensions (length × width), mm|(% style="width:160px" %)123 × 118 19 19 |Mounting holes|(% style="width:160px" %)M4 20 -|Headers X1-X4 type|(% style="width:160px" %)Molex series Micro-Fit 21 21 22 -== 2.2Headers ==22 +== Headers == 23 23 24 24 The BMS Logic 12 is designed to measure temperature and voltage of 12 battery cells. 25 25 26 -[[image:173 3143089674-767.png||data-xwiki-image-style-alignment="center" height="356" width="531"]]26 +[[image:1736770542979-717.png||data-xwiki-image-style-alignment="center" height="356" width="450"]] 27 27 28 -=== 2.2.1 X1 – header for cells === 28 +(% class="box warningmessage" %) 29 +((( 30 +**Attention!** 31 +All headers are shown from the device side! 32 +))) 29 29 34 +=== X1 – header for cells === 35 + 36 +Receptacle Housing: Molex 430251400. Terminals: Molex 43030 37 + 30 30 [[image:1733143152741-474.jpeg||data-xwiki-image-style-alignment="center" height="81" width="210"]] 31 31 32 32 |**Pin**|**Name**|**Description** ... ... @@ -45,8 +45,10 @@ 45 45 |**13**|**C9**|Cell #9 46 46 |**14**|**C11**|Cell #11 47 47 48 -=== 2.2.2X2 – header for temperature sensors ===56 +=== X2 – header for temperature sensors === 49 49 58 +Receptacle Housing: Molex 430252400. Terminals: Molex 43030 59 + 50 50 [[image:1733143152745-708.jpeg||data-xwiki-image-style-alignment="center" height="92" width="368"]] 51 51 52 52 |**Pin**|**Name**|**Description** ... ... @@ -75,8 +75,10 @@ 75 75 |**23**|**TEMP2**|Signal from the thermistor #2 76 76 |**24**|**TEMP1**|Signal from the thermistor #1 77 77 78 -=== 2.2.3X3, X4 – headers for communication with BMS Main ===88 +=== X3, X4 – headers for communication with BMS Main === 79 79 90 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 91 + 80 80 [[image:1733151077073-306.png||data-xwiki-image-style-alignment="center" height="78" width="71"]] 81 81 82 82 |**Pin**|**Name**|**Description** ... ... @@ -85,9 +85,9 @@ 85 85 |**3**|**+5V**|Supply voltage 5V 86 86 |**4**|**GND**|Ground 87 87 88 -(% style="color:inherit; font-family:inherit; font-size:max(20px, min(24px, 12.8889px + 0.925926vw))" %) 2.3Switches and indicators100 +== (% style="color:inherit; font-family:inherit; font-size:max(20px, min(24px, 12.8889px + 0.925926vw))" %)Switches and indicators(%%) == 89 89 90 -=== 2.3.1SWD1 – address switch ===102 +=== SWD1 – address switch === 91 91 92 92 |**Switch number**|**Description** 93 93 |**1**|The first (the lowest) bit of the address. Position ON - bit is 1 ... ... @@ -98,10 +98,10 @@ 98 98 99 99 (% class="box infomessage" %) 100 100 ((( 101 -**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 12. The device address must be configured in the settings (see the section [[ 3.Configuration>>doc:drafts.BMS Logic 12.3\. Configuration.WebHome]]).113 +**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 12. The device address must be configured in the settings (see the section [[Configuration>>doc:Battery management systems.BMS Logic 12.3\. Configuration.WebHome]]). 102 102 ))) 103 103 104 -=== 2.3.2SWD2 – RS-485 termination resistor switch ===116 +=== SWD2 – RS-485 termination resistor switch === 105 105 106 106 To connect the termination resistor between the **RS485_A** and **RS485_B** lines, switch the SWD2 to the ON position. 107 107 ... ... @@ -110,7 +110,7 @@ 110 110 **Note: **There is no SWD2 switch in the recent revisions of the BMS Logic 12. Connect a 120 Ohm termination resistor directly to the X4 connector between the lines RS485_A and RS485_B. 111 111 ))) 112 112 113 -=== 2.3.3DS1 – mode indicator ===125 +=== DS1 – mode indicator === 114 114 115 115 (% style="width:718px" %) 116 116 |**State**|(% style="width:422px" %)**Description** ... ... @@ -118,9 +118,9 @@ 118 118 |Short flashing (~~50 milliseconds in a second)|(% style="width:422px" %)The device is measuring voltage and temperature. No communication between the BMS Main and the device 119 119 |Long flashing (1 second in a 2 second period)|(% style="width:422px" %)The device is in the bootloader mode 120 120 121 -== 2.4Connection procedure ==133 +== Connection procedure == 122 122 123 -=== 2.4.1Connection to BMS Main ===135 +=== Connection to BMS Main === 124 124 125 125 To connect the BMS Main to BMS Logic 12 do the following steps: 126 126 ... ... @@ -136,7 +136,7 @@ 136 136 3. For a total cable length of more than 10 meters use twisted pair with the 120 Ohm wave impedance. 137 137 ))) 138 138 139 -=== 2.4.2Connecting battery cells ===151 +=== Connecting battery cells === 140 140 141 141 To connect the battery cells, follow Figure 16. Incorrect connection of the cells can damage the BMS Logic 12. 142 142 ... ... @@ -151,7 +151,7 @@ 151 151 Connect the battery according to the diagram, otherwise the device may be damaged. 152 152 ))) 153 153 154 -=== 2.4.3Connecting thermistors ===166 +=== Connecting thermistors === 155 155 156 156 Thermistors should be fastened to the cells, excluding short circuits to the cell terminals (for example, isolate thermistors with heat shrink). For reliable operation, it is recommended to use all thermistors (a temperature sensor per cell). 157 157
- 1736770542979-717.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.4 KB - Content
- 1736773655076-566.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.4 KB - Content