Last modified by Admin on 2025/03/18 13:04

From version 7.1
edited by Admin
on 2024/12/02 14:53
Change comment: There is no comment for this version
To version 3.1
edited by Admin
on 2024/12/02 13:17
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -19,7 +19,7 @@
19 19  |Mounting holes|(% style="width:160px" %)M4
20 20  |Headers X1-X4 type|(% style="width:160px" %)Molex series Micro-Fit
21 21  
22 -== 2.2 Headers ==
22 +== 2.2 Headers description ==
23 23  
24 24  The BMS Logic 12 is designed to measure temperature and voltage of 12 battery cells.
25 25  
... ... @@ -77,8 +77,6 @@
77 77  
78 78  === 2.2.3 X3, X4 – headers for communication with BMS Main ===
79 79  
80 -[[image:1733151077073-306.png||data-xwiki-image-style-alignment="center" height="78" width="71"]]
81 -
82 82  |**Pin**|**Name**|**Description**
83 83  |**1**|**RS485_A**|RS-485 line A for communication with the BMS Main
84 84  |**2**|**RS485_B**|RS-485 line B for communication with the BMS Main
... ... @@ -85,7 +85,7 @@
85 85  |**3**|**+5V**|Supply voltage 5V
86 86  |**4**|**GND**|Ground
87 87  
88 -(% style="color:inherit; font-family:inherit; font-size:max(20px, min(24px, 12.8889px + 0.925926vw))" %)2.3 Switches and indicators
86 +== 2.3 Switches and indicators ==
89 89  
90 90  === 2.3.1 SWD1 – address switch ===
91 91  
... ... @@ -98,7 +98,7 @@
98 98  
99 99  (% class="box infomessage" %)
100 100  (((
101 -**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 12. The device address must be configured in the settings (see the section [[3. Configuration>>doc:drafts.BMS Logic 12.3\. Configuration.WebHome]]).
99 +**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 12. The device address must be configured in the settings (see the section 3.2** **Configuration procedure).
102 102  )))
103 103  
104 104  === 2.3.2 SWD2 – RS-485 termination resistor switch ===
... ... @@ -142,8 +142,8 @@
142 142  
143 143  Begin the connection with the negative of the battery: the "V-" of the first BMS Logic 12 is connected to "B-", then the first cell (C1) of the battery is connected, then the second (C2), etc. The “V-“ of the next BMS Logic 12 is connected to the C12 of the previous BMS Logic 12. If not all inputs of the cells are used, then the remaining inputs are connected to the cell with the highest potential.
144 144  
145 -[[image:1733145484804-250.jpeg||data-xwiki-image-style-alignment="center" height="507" width="587"]]
146 146  
144 +[[image:1733143549304-570.jpeg||data-xwiki-image-style-alignment="center" height="572" width="662"]]
147 147  
148 148  (% class="box warningmessage" %)
149 149  (((
1733145484804-250.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -96.7 KB
Content
1733151077073-306.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -1.7 KB
Content