... ... @@ -19,7 +19,7 @@
19 19  |Mounting holes|(% style="width:160px" %)M4
20 20  |Headers X1-X4 type|(% style="width:160px" %)Molex series Micro-Fit
21 21  
22 -== 2.2 Headers description ==
22 +== 2.2 Headers ==
23 23  
24 24  The BMS Logic 12 is designed to measure temperature and voltage of 12 battery cells.
25 25  
... ... @@ -77,6 +77,8 @@
77 77  
78 78  === 2.2.3 X3, X4 – headers for communication with BMS Main ===
79 79  
80 +[[image:1733151077073-306.png||data-xwiki-image-style-alignment="center" height="78" width="71"]]
81 +
80 80  |**Pin**|**Name**|**Description**
81 81  |**1**|**RS485_A**|RS-485 line A for communication with the BMS Main
82 82  |**2**|**RS485_B**|RS-485 line B for communication with the BMS Main
... ... @@ -83,7 +83,7 @@
83 83  |**3**|**+5V**|Supply voltage 5V
84 84  |**4**|**GND**|Ground
85 85  
86 -== 2.3 Switches and indicators ==
88 +(% style="color:inherit; font-family:inherit; font-size:max(20px, min(24px, 12.8889px + 0.925926vw))" %)2.3 Switches and indicators
87 87  
88 88  === 2.3.1 SWD1 – address switch ===
89 89  
... ... @@ -96,7 +96,7 @@
96 96  
97 97  (% class="box infomessage" %)
98 98  (((
99 -**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 12. The device address must be configured in the settings (see the section 3.2** **Configuration procedure).
101 +**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 12. The device address must be configured in the settings (see the section [[3.** **Configuration procedure>>doc:drafts.BMS Logic 12.3\. Configuration.WebHome]]).
100 100  )))
101 101  
102 102  === 2.3.2 SWD2 – RS-485 termination resistor switch ===
... ... @@ -140,8 +140,8 @@
140 140  
141 141  Begin the connection with the negative of the battery: the "V-" of the first BMS Logic 12 is connected to "B-", then the first cell (C1) of the battery is connected, then the second (C2), etc. The “V-“ of the next BMS Logic 12 is connected to the C12 of the previous BMS Logic 12. If not all inputs of the cells are used, then the remaining inputs are connected to the cell with the highest potential.
142 142  
145 +[[image:1733145484804-250.jpeg||data-xwiki-image-style-alignment="center" height="507" width="587"]]
143 143  
144 -[[image:1733143549304-570.jpeg||data-xwiki-image-style-alignment="center" height="572" width="662"]]
145 145  
146 146  (% class="box warningmessage" %)
147 147  (((
1733145484804-250.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +96.7 KB
Content
1733151077073-306.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +1.7 KB
Content