Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 13:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -11,13 +11,16 @@ 11 11 12 12 Overall and mounting dimensions of the BMS Logic 12 are shown below. 13 13 14 -[[image:173 6773655076-566.png||data-xwiki-image-style-alignment="center" height="534" width="600"]]14 +[[image:1733142832467-386.png||data-xwiki-image-style-alignment="center" height="410" width="486"]] 15 15 16 + 17 + 16 16 (% style="width:477px" %) 17 17 |**Parameter**|(% style="width:160px" %)**Value** 18 18 |Overall dimensions (length × width × height), mm|(% style="width:160px" %)139 × 126 × 16 19 19 |Mounting dimensions (length × width), mm|(% style="width:160px" %)123 × 118 20 20 |Mounting holes|(% style="width:160px" %)M4 23 +|Headers X1-X4 type|(% style="width:160px" %)Molex series Micro-Fit 21 21 22 22 == Headers == 23 23 ... ... @@ -33,8 +33,6 @@ 33 33 34 34 === X1 – header for cells === 35 35 36 -Receptacle Housing: Molex 430251400. Terminals: Molex 43030 37 - 38 38 [[image:1733143152741-474.jpeg||data-xwiki-image-style-alignment="center" height="81" width="210"]] 39 39 40 40 |**Pin**|**Name**|**Description** ... ... @@ -55,8 +55,6 @@ 55 55 56 56 === X2 – header for temperature sensors === 57 57 58 -Receptacle Housing: Molex 430252400. Terminals: Molex 43030 59 - 60 60 [[image:1733143152745-708.jpeg||data-xwiki-image-style-alignment="center" height="92" width="368"]] 61 61 62 62 |**Pin**|**Name**|**Description** ... ... @@ -87,8 +87,6 @@ 87 87 88 88 === X3, X4 – headers for communication with BMS Main === 89 89 90 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030 91 - 92 92 [[image:1733151077073-306.png||data-xwiki-image-style-alignment="center" height="78" width="71"]] 93 93 94 94 |**Pin**|**Name**|**Description**