Last modified by Admin on 2025/03/18 13:04

From version 19.1
edited by Admin
on 2025/02/20 12:46
Change comment: There is no comment for this version
To version 13.2
edited by Admin
on 2024/12/11 11:19
Change comment: Update document after refactoring.

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,5 @@
1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 -= nstallation and connection =
2 += Installation and connection =
3 3  
4 4  == Installation procedure ==
5 5  
... ... @@ -11,19 +11,22 @@
11 11  
12 12  Overall and mounting dimensions of the BMS Logic 12 are shown below.
13 13  
14 -[[image:1736773655076-566.png||data-xwiki-image-style-alignment="center" height="534" width="600"]]
14 +[[image:1733142832467-386.png||data-xwiki-image-style-alignment="center" height="410" width="486"]]
15 15  
16 +
17 +
16 16  (% style="width:477px" %)
17 17  |**Parameter**|(% style="width:160px" %)**Value**
18 18  |Overall dimensions (length × width × height), mm|(% style="width:160px" %)139 × 126 × 16
19 19  |Mounting dimensions (length × width), mm|(% style="width:160px" %)123 × 118
20 20  |Mounting holes|(% style="width:160px" %)M4
23 +|Headers X1-X4 type|(% style="width:160px" %)Molex series Micro-Fit
21 21  
22 22  == Headers ==
23 23  
24 24  The BMS Logic 12 is designed to measure temperature and voltage of 12 battery cells.
25 25  
26 -[[image:1736770542979-717.png||data-xwiki-image-style-alignment="center" height="356" width="450"]]
29 +[[image:1733143089674-767.png||data-xwiki-image-style-alignment="center" height="356" width="531"]]
27 27  
28 28  (% class="box warningmessage" %)
29 29  (((
... ... @@ -33,8 +33,6 @@
33 33  
34 34  === X1 – header for cells ===
35 35  
36 -Receptacle Housing: Molex 430251400. Terminals: Molex 43030
37 -
38 38  [[image:1733143152741-474.jpeg||data-xwiki-image-style-alignment="center" height="81" width="210"]]
39 39  
40 40  |**Pin**|**Name**|**Description**
... ... @@ -106,7 +106,7 @@
106 106  
107 107  (% class="box infomessage" %)
108 108  (((
109 -**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 12. The device address must be configured in the settings (see the section [[Configuration>>doc:Battery management systems.BMS Logic 12.3\. Configuration.WebHome]]).
110 +**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 12. The device address must be configured in the settings (see the section [[Configuration>>doc:drafts.BMS Logic 12.3\. Configuration.WebHome]]).
110 110  )))
111 111  
112 112  === SWD2 – RS-485 termination resistor switch ===
1736770542979-717.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -39.4 KB
Content
1736773655076-566.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -35.4 KB
Content