Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 13:04
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 5 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS Logic 12.WebHome1 +drafts.BMS Logic 12.WebHome - Content
-
... ... @@ -1,8 +1,5 @@ 1 -(% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= nstallation and connection = 1 +== 2.1 Installation procedure == 3 3 4 -== Installation procedure == 5 - 6 6 The mounting area of the BMS Logic 12 must be protected from mechanical particles (dust, dirt, large objects) and water. The BMS Logic 12 is recommended to be placed close to the cells it controls, but away from high current circuits to reduce interference to measuring circuits and increase overall reliability of installation. 7 7 8 8 The installation site must provide convenient access for subsequent connection to the device’s headers. ... ... @@ -22,22 +22,16 @@ 22 22 |Mounting holes|(% style="width:160px" %)M4 23 23 |Headers X1-X4 type|(% style="width:160px" %)Molex series Micro-Fit 24 24 25 -== Headers == 22 +== 2.2 Headers description == 26 26 27 27 The BMS Logic 12 is designed to measure temperature and voltage of 12 battery cells. 28 28 29 -[[image:173 6770542979-717.png||data-xwiki-image-style-alignment="center" height="356" width="450"]]26 +[[image:1733143089674-767.png||data-xwiki-image-style-alignment="center" height="356" width="531"]] 30 30 31 -(% class="box warningmessage" %) 32 -((( 33 -**Attention!** 34 -All headers are shown from the device side! 35 -))) 28 +=== 2.2.1 X1 – header for cells === 36 36 37 - === X1– headerfor cells===30 +[[image:1733143152741-474.jpeg||data-xwiki-image-style-alignment="center" height="93" width="241"]] 38 38 39 -[[image:1733143152741-474.jpeg||data-xwiki-image-style-alignment="center" height="81" width="210"]] 40 - 41 41 |**Pin**|**Name**|**Description** 42 42 |**1**|**V-**|Minus of the cell stack 43 43 |**2**|**C2**|Cell #2 ... ... @@ -54,7 +54,7 @@ 54 54 |**13**|**C9**|Cell #9 55 55 |**14**|**C11**|Cell #11 56 56 57 -=== X2 – header for temperature sensors === 48 +=== 2.2.2 X2 – header for temperature sensors === 58 58 59 59 [[image:1733143152745-708.jpeg||data-xwiki-image-style-alignment="center" height="92" width="368"]] 60 60 ... ... @@ -84,10 +84,8 @@ 84 84 |**23**|**TEMP2**|Signal from the thermistor #2 85 85 |**24**|**TEMP1**|Signal from the thermistor #1 86 86 87 -=== X3, X4 – headers for communication with BMS Main === 78 +=== 2.2.3 X3, X4 – headers for communication with BMS Main === 88 88 89 -[[image:1733151077073-306.png||data-xwiki-image-style-alignment="center" height="78" width="71"]] 90 - 91 91 |**Pin**|**Name**|**Description** 92 92 |**1**|**RS485_A**|RS-485 line A for communication with the BMS Main 93 93 |**2**|**RS485_B**|RS-485 line B for communication with the BMS Main ... ... @@ -94,9 +94,9 @@ 94 94 |**3**|**+5V**|Supply voltage 5V 95 95 |**4**|**GND**|Ground 96 96 97 -== (% style="color:inherit; font-family:inherit; font-size:max(20px, min(24px, 12.8889px+ 0.925926vw))" %)Switches and indicators(%%)==86 +== 2.3 Switches and indicators == 98 98 99 -=== SWD1 – address switch === 88 +=== 2.3.1 SWD1 – address switch === 100 100 101 101 |**Switch number**|**Description** 102 102 |**1**|The first (the lowest) bit of the address. Position ON - bit is 1 ... ... @@ -107,10 +107,10 @@ 107 107 108 108 (% class="box infomessage" %) 109 109 ((( 110 -**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 12. The device address must be configured in the settings (see the section [[Configuration>>doc:Batterymanagement systems.BMS Logic12.3\. Configuration.WebHome]]).99 +**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 12. The device address must be configured in the settings (see the section 3.2** **Configuration procedure). 111 111 ))) 112 112 113 -=== SWD2 – RS-485 termination resistor switch === 102 +=== 2.3.2 SWD2 – RS-485 termination resistor switch === 114 114 115 115 To connect the termination resistor between the **RS485_A** and **RS485_B** lines, switch the SWD2 to the ON position. 116 116 ... ... @@ -119,51 +119,11 @@ 119 119 **Note: **There is no SWD2 switch in the recent revisions of the BMS Logic 12. Connect a 120 Ohm termination resistor directly to the X4 connector between the lines RS485_A and RS485_B. 120 120 ))) 121 121 122 -=== DS1 – mode indicator === 111 +=== 2.3.3 DS1 – mode indicator === 123 123 124 -(% style="width:718px" %) 125 -|**State**|(% style="width:422px" %)**Description** 126 -|Blinking|(% style="width:422px" %)Connection between the BMS Main and the device is established 127 -|Short flashing (~~50 milliseconds in a second)|(% style="width:422px" %)The device is measuring voltage and temperature. No communication between the BMS Main and the device 128 -|Long flashing (1 second in a 2 second period)|(% style="width:422px" %)The device is in the bootloader mode 113 +|**State**|**Description** 114 +|Blinking|Connection between the BMS Main and the device is established 115 +|Short flashing (~~50 milliseconds in a second)|The device is measuring voltage and temperature. No communication between the BMS Main and the device 116 +|Long flashing (1 second in a 2 second period)|The device is in the bootloader mode 129 129 130 -== Connection procedure == 131 - 132 -=== Connection to BMS Main === 133 - 134 -To connect the BMS Main to BMS Logic 12 do the following steps: 135 - 136 -1. Connect the BMS Main to the first BMS Logic 12 (P15 -> X3). 137 -1. Connect the BMS Logic 12 to each other (X4 -> X3). 138 -1. Switch SWD2 on the last BMS Logic 12 to the ON position or connect a 120 Ohm termination resistor directly to the X4 connector of the last BMS Logic 12. 139 - 140 -(% class="box infomessage" %) 141 -((( 142 -**Recommendations:** 143 -~1. The total cable length (the sum of the lengths of all cables) between the BMS Main and the last BMS Logic 12 should not exceed 500 meters. 144 -2. Make all connections with the same cable. 145 -3. For a total cable length of more than 10 meters use twisted pair with the 120 Ohm wave impedance. 146 -))) 147 - 148 -=== Connecting battery cells === 149 - 150 -To connect the battery cells, follow Figure 16. Incorrect connection of the cells can damage the BMS Logic 12. 151 - 152 -Begin the connection with the negative of the battery: the "V-" of the first BMS Logic 12 is connected to "B-", then the first cell (C1) of the battery is connected, then the second (C2), etc. The “V-“ of the next BMS Logic 12 is connected to the C12 of the previous BMS Logic 12. If not all inputs of the cells are used, then the remaining inputs are connected to the cell with the highest potential. 153 - 154 -[[image:1733145484804-250.jpeg||data-xwiki-image-style-alignment="center" height="507" width="587"]] 155 - 156 - 157 -(% class="box warningmessage" %) 158 -((( 159 -**Attention!** 160 -Connect the battery according to the diagram, otherwise the device may be damaged. 161 -))) 162 - 163 -=== Connecting thermistors === 164 - 165 -Thermistors should be fastened to the cells, excluding short circuits to the cell terminals (for example, isolate thermistors with heat shrink). For reliable operation, it is recommended to use all thermistors (a temperature sensor per cell). 166 - 167 -[[image:1733231119798-210.jpeg||data-xwiki-image-style-alignment="center" height="408" width="539"]] 168 - 169 169
- 1733145484804-250.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -96.7 KB - Content
- 1733151077073-306.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.7 KB - Content
- 1733231119798-210.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -109.2 KB - Content
- 1736770542979-717.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -39.4 KB - Content
- 1736773655076-566.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -35.4 KB - Content