Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 13:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Installation and connection =2 += nstallation and connection = 3 3 4 4 == Installation procedure == 5 5 ... ... @@ -26,7 +26,7 @@ 26 26 27 27 The BMS Logic 12 is designed to measure temperature and voltage of 12 battery cells. 28 28 29 -[[image:173 3143089674-767.png||data-xwiki-image-style-alignment="center" height="356" width="531"]]29 +[[image:1736770542979-717.png||data-xwiki-image-style-alignment="center" height="356" width="450"]] 30 30 31 31 (% class="box warningmessage" %) 32 32 ((( ... ... @@ -107,7 +107,7 @@ 107 107 108 108 (% class="box infomessage" %) 109 109 ((( 110 -**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 12. The device address must be configured in the settings (see the section [[Configuration>>doc: drafts.BMS Logic 12.3\. Configuration.WebHome]]).110 +**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 12. The device address must be configured in the settings (see the section [[Configuration>>doc:Battery management systems.BMS Logic 12.3\. Configuration.WebHome]]). 111 111 ))) 112 112 113 113 === SWD2 – RS-485 termination resistor switch ===
- 1736770542979-717.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.4 KB - Content