Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 13:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -25,12 +25,6 @@ 25 25 26 26 [[image:1733143089674-767.png||data-xwiki-image-style-alignment="center" height="356" width="531"]] 27 27 28 -(% class="box warningmessage" %) 29 -((( 30 -**Attention!** 31 -All connectors are shown from the device side! 32 -))) 33 - 34 34 === 2.2.1 X1 – header for cells === 35 35 36 36 [[image:1733143152741-474.jpeg||data-xwiki-image-style-alignment="center" height="81" width="210"]] ... ... @@ -83,8 +83,6 @@ 83 83 84 84 === 2.2.3 X3, X4 – headers for communication with BMS Main === 85 85 86 -[[image:1733151077073-306.png||data-xwiki-image-style-alignment="center" height="78" width="71"]] 87 - 88 88 |**Pin**|**Name**|**Description** 89 89 |**1**|**RS485_A**|RS-485 line A for communication with the BMS Main 90 90 |**2**|**RS485_B**|RS-485 line B for communication with the BMS Main ... ... @@ -91,7 +91,7 @@ 91 91 |**3**|**+5V**|Supply voltage 5V 92 92 |**4**|**GND**|Ground 93 93 94 - (% style="color:inherit;font-family:inherit; font-size:max(20px, min(24px, 12.8889px + 0.925926vw))" %)2.3 Switches and indicators86 +== 2.3 Switches and indicators == 95 95 96 96 === 2.3.1 SWD1 – address switch === 97 97 ... ... @@ -104,7 +104,7 @@ 104 104 105 105 (% class="box infomessage" %) 106 106 ((( 107 -**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 12. The device address must be configured in the settings (see the section [[3. Configuration>>doc:drafts.BMSLogic12.3\. Configuration.WebHome]]).99 +**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 12. The device address must be configured in the settings (see the section 3.2** **Configuration procedure). 108 108 ))) 109 109 110 110 === 2.3.2 SWD2 – RS-485 termination resistor switch === ... ... @@ -160,7 +160,3 @@ 160 160 === 2.4.3 Connecting thermistors === 161 161 162 162 Thermistors should be fastened to the cells, excluding short circuits to the cell terminals (for example, isolate thermistors with heat shrink). For reliable operation, it is recommended to use all thermistors (a temperature sensor per cell). 163 - 164 -[[image:1733231119798-210.jpeg||data-xwiki-image-style-alignment="center" height="408" width="539"]] 165 - 166 -
- 1733151077073-306.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.7 KB - Content
- 1733231119798-210.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -109.2 KB - Content