Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/12 11:13
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,23 +1,29 @@ 1 +(% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Technical specifications = 3 + 1 1 [[image:https://movicomelectric.com/wa-data/public/site/img/10-BMS-Logic-12-34.png||alt="Logic 12" data-xwiki-image-style-alignment="center" height="224" width="442"]] 2 2 3 3 BMS Logic 12 represents the second generation of measuring modules that takes the best from BMS Logic 2.0 and offers greater accuracy and energy efficiency. It determines voltage and temperature of the battery cells and does passive balancing of the cells on a command from the BMS controller. 4 4 5 -== 1.1Specifications ==8 +== Specifications == 6 6 7 -|**Parameter**|**Value** 8 -|Supply voltage, V|5.0 ± 0.5 9 -|Current consumption @5 V, mA (typical)|4 10 -|Cell stack voltage, V|10 to 80 11 -|Power consumption @Cell stack, mW (maximum)|175 12 -|Number of cells|4 to 12 13 -|Balancing current @4.2 V on a cell, mA (average)|350 14 -|Cell voltage measurement error, V (maximum)|±0.003 15 -|Cell temperature measurement error, °С (maximum)|±2 16 -|Dimensions (length × width × height), mm|139 × 126 × 16 17 -|Weight, g|230 ± 5 18 -|Operating temperature range, ºС|-40 to +85 19 -|Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|3500 10 +(% style="width:605px" %) 11 +|(% style="width:472px" %)**Parameter**|(% style="width:130px" %)**Value** 12 +|(% style="width:472px" %)Supply voltage, V|(% style="width:130px" %)5.0 ± 0.5 13 +|(% style="width:472px" %)Current consumption @5 V, mA (typical)|(% style="width:130px" %)4 14 +|(% style="width:472px" %)Cell stack voltage, V|(% style="width:130px" %)10 to 80 15 +|(% style="width:472px" %)Power consumption @Cell stack, mW (maximum)|(% style="width:130px" %)175 16 +|(% style="width:472px" %)Number of cells|(% style="width:130px" %)4 to 12 17 +|(% style="width:472px" %)Balancing current @4.2 V on a cell, mA (average)|(% style="width:130px" %)350 18 +|(% style="width:472px" %)Cell voltage measurement error, V (maximum)|(% style="width:130px" %)±0.003 19 +|(% style="width:472px" %)Cell temperature measurement error, °С (maximum)|(% style="width:130px" %)±2 20 +|(% style="width:472px" %)Dimensions (length × width × height), mm|(% style="width:130px" %)139 × 126 × 16 21 +|(% style="width:472px" %)Weight, g|(% style="width:130px" %)230 ± 5 22 +|(% style="width:472px" %)Operating temperature range, ºС|(% style="width:130px" %)-40 to +85 23 +|(% style="width:472px" %)Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|(% style="width:130px" %)3500 20 20 21 -== 1.2Overall and mounting dimensions ==25 +== Overall and mounting dimensions == 22 22 23 23 [[image:1733141406083-452.png||data-xwiki-image-style-alignment="center" height="494" width="468"]] 28 + 29 +