7 -|**Parameter**|**Value**
8 -|Supply voltage, V|5.0 ± 0.5
9 -|Current consumption @5 V, mA (typical)|4
10 -|Cell stack voltage, V|10 to 80
11 -|Power consumption @Cell stack, mW (maximum)|175
12 -|Number of cells|4 to 12
13 -|Balancing current @4.2 V on a cell, mA (average)|350
14 -|Cell voltage measurement error, V (maximum)|±0.003
15 -|Cell temperature measurement error, °С (maximum)|±2
16 -|Dimensions (length × width × height), mm|139 × 126 × 16
17 -|Weight, g|230 ± 5
18 -|Operating temperature range, ºС|-40 to +85
19 -|Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|3500
7 +(% style="width:605px" %)
8 +|(% style="width:472px" %)**Parameter**|(% style="width:130px" %)**Value**
9 +|(% style="width:472px" %)Supply voltage, V|(% style="width:130px" %)5.0 ± 0.5
10 +|(% style="width:472px" %)Current consumption @5 V, mA (typical)|(% style="width:130px" %)4
11 +|(% style="width:472px" %)Cell stack voltage, V|(% style="width:130px" %)10 to 80
12 +|(% style="width:472px" %)Power consumption @Cell stack, mW (maximum)|(% style="width:130px" %)175
13 +|(% style="width:472px" %)Number of cells|(% style="width:130px" %)4 to 12
14 +|(% style="width:472px" %)Balancing current @4.2 V on a cell, mA (average)|(% style="width:130px" %)350
15 +|(% style="width:472px" %)Cell voltage measurement error, V (maximum)|(% style="width:130px" %)±0.003
16 +|(% style="width:472px" %)Cell temperature measurement error, °С (maximum)|(% style="width:130px" %)±2
17 +|(% style="width:472px" %)Dimensions (length × width × height), mm|(% style="width:130px" %)139 × 126 × 16
18 +|(% style="width:472px" %)Weight, g|(% style="width:130px" %)230 ± 5
19 +|(% style="width:472px" %)Operating temperature range, ºС|(% style="width:130px" %)-40 to +85
20 +|(% style="width:472px" %)Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|(% style="width:130px" %)3500