Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/12 11:13
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,21 +1,26 @@ 1 +[[image:https://movicomelectric.com/wa-data/public/site/img/10-BMS-Logic-12-34.png||alt="Logic 12" data-xwiki-image-style-alignment="center" height="224" width="442"]] 2 + 1 1 BMS Logic 12 represents the second generation of measuring modules that takes the best from BMS Logic 2.0 and offers greater accuracy and energy efficiency. It determines voltage and temperature of the battery cells and does passive balancing of the cells on a command from the BMS controller. 2 2 3 3 == 1.1 Specifications == 4 4 5 -|**Parameter**|**Value** 6 -|Supply voltage, V|5.0 ± 0.5 7 -|Current consumption @5 V, mA (typical)|4 8 -|Cell stack voltage, V|10 to 80 9 -|Power consumption @Cell stack, mW (maximum)|175 10 -|Number of cells|4 to 12 11 -|Balancing current @4.2 V on a cell, mA (average)|350 12 -|Cell voltage measurement error, V (maximum)|±0.003 13 -|Cell temperature measurement error, °С (maximum)|±2 14 -|Dimensions (length × width × height), mm|139 × 126 × 16 15 -|Weight, g|230 ± 5 16 -|Operating temperature range, ºС|-40 to +85 17 -|Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|3500 7 +(% style="width:605px" %) 8 +|(% style="width:472px" %)**Parameter**|(% style="width:130px" %)**Value** 9 +|(% style="width:472px" %)Supply voltage, V|(% style="width:130px" %)5.0 ± 0.5 10 +|(% style="width:472px" %)Current consumption @5 V, mA (typical)|(% style="width:130px" %)4 11 +|(% style="width:472px" %)Cell stack voltage, V|(% style="width:130px" %)10 to 80 12 +|(% style="width:472px" %)Power consumption @Cell stack, mW (maximum)|(% style="width:130px" %)175 13 +|(% style="width:472px" %)Number of cells|(% style="width:130px" %)4 to 12 14 +|(% style="width:472px" %)Balancing current @4.2 V on a cell, mA (average)|(% style="width:130px" %)350 15 +|(% style="width:472px" %)Cell voltage measurement error, V (maximum)|(% style="width:130px" %)±0.003 16 +|(% style="width:472px" %)Cell temperature measurement error, °С (maximum)|(% style="width:130px" %)±2 17 +|(% style="width:472px" %)Dimensions (length × width × height), mm|(% style="width:130px" %)139 × 126 × 16 18 +|(% style="width:472px" %)Weight, g|(% style="width:130px" %)230 ± 5 19 +|(% style="width:472px" %)Operating temperature range, ºС|(% style="width:130px" %)-40 to +85 20 +|(% style="width:472px" %)Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|(% style="width:130px" %)3500 18 18 19 19 == 1.2 Overall and mounting dimensions == 20 20 21 -[[image:1733141406083-452.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="494" width="468"]] 24 +[[image:1733141406083-452.png||data-xwiki-image-style-alignment="center" height="494" width="468"]] 25 + 26 +