Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/12 11:13
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7,23 +7,24 @@ 7 7 8 8 == Specifications == 9 9 10 -(% style="width:605px" %) 11 -|(% style="width:472px" %)**Parameter**|(% style="width:130px" %)**Value** 12 -|(% style="width:472px" %)Supply voltage, V|(% style="width:130px" %)5.0 ± 0.5 13 -|(% style="width:472px" %)Current consumption @5 V, mA (typical)|(% style="width:130px" %)4 14 -|(% style="width:472px" %)Cell stack voltage, V|(% style="width:130px" %)10 to 80 15 -|(% style="width:472px" %)Power consumption @Cell stack, mW (maximum)|(% style="width:130px" %)175 16 -|(% style="width:472px" %)Number of cells|(% style="width:130px" %)4 to 12 17 -|(% style="width:472px" %)Balancing current @4.2 V on a cell, mA (average)|(% style="width:130px" %)350 18 -|(% style="width:472px" %)Cell voltage measurement error, V (maximum)|(% style="width:130px" %)±0.003 19 -|(% style="width:472px" %)Cell temperature measurement error, °С (maximum)|(% style="width:130px" %)±2 20 -|(% style="width:472px" %)Dimensions (length × width × height), mm|(% style="width:130px" %)139 × 126 × 16 21 -|(% style="width:472px" %)Weight, g|(% style="width:130px" %)230 ± 5 22 -|(% style="width:472px" %)Operating temperature range, ºС|(% style="width:130px" %)-40 to +85 23 -|(% style="width:472px" %)Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|(% style="width:130px" %)3500 10 +(% style="width:628px" %) 11 +|(% style="width:472px" %)**Parameter**|(% style="width:151px" %)**Value** 12 +|(% style="width:472px" %)Supply voltage, V|(% style="width:151px" %)5.0 ± 0.5 13 +|(% style="width:472px" %)Current consumption @5 V, mA (typical)|(% style="width:151px" %)4 14 +|(% style="width:472px" %)Cell stack voltage, V|(% style="width:151px" %)10 to 80 15 +|(% style="width:472px" %)Power consumption @Cell stack, mW (maximum)|(% style="width:151px" %)175 16 +|(% style="width:472px" %)Number of cells|(% style="width:151px" %)4 to 12 17 +|(% style="width:472px" %)Balancing current @4.2 V on a cell, mA (average)|(% style="width:151px" %)350 18 +|(% style="width:472px" %)Cell voltage measurement error, V (maximum)|(% style="width:151px" %)±0.003 19 +|(% style="width:472px" %)Cell temperature measurement error, °С (maximum)|(% style="width:151px" %)±2 20 +|(% style="width:472px" %)Dimensions (length × width × height), mm|(% style="width:151px" %)139 × 126 × 16 21 +|(% style="width:472px" %)Weight, g|(% style="width:151px" %)230 ± 5 22 +|(% style="width:472px" %)Operating temperature range, ºС|(% style="width:151px" %)-40 to +85 23 +|(% style="width:472px" %)Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|(% style="width:151px" %)3500 24 +|Headers X1-X4 type|(% style="width:151px" %)Molex series Micro-Fit 24 24 25 25 == Overall and mounting dimensions == 26 26 27 -[[image:17 36773614836-174.png||data-xwiki-image-style-alignment="center" height="651" width="600"]]28 +[[image:1746619842455-105.png||data-xwiki-image-style-alignment="center" height="492" width="450"]] 28 28 29 29
- 1746619842455-105.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.5 KB - Content