Summary

Details

Page properties
Content
... ... @@ -7,20 +7,21 @@
7 7  
8 8  == Specifications ==
9 9  
10 -(% style="width:605px" %)
11 -|(% style="width:472px" %)**Parameter**|(% style="width:130px" %)**Value**
12 -|(% style="width:472px" %)Supply voltage, V|(% style="width:130px" %)5.0 ± 0.5
13 -|(% style="width:472px" %)Current consumption @5 V, mA (typical)|(% style="width:130px" %)4
14 -|(% style="width:472px" %)Cell stack voltage, V|(% style="width:130px" %)10 to 80
15 -|(% style="width:472px" %)Power consumption @Cell stack, mW (maximum)|(% style="width:130px" %)175
16 -|(% style="width:472px" %)Number of cells|(% style="width:130px" %)4 to 12
17 -|(% style="width:472px" %)Balancing current @4.2 V on a cell, mA (average)|(% style="width:130px" %)350
18 -|(% style="width:472px" %)Cell voltage measurement error, V (maximum)|(% style="width:130px" %)±0.003
19 -|(% style="width:472px" %)Cell temperature measurement error, °С (maximum)|(% style="width:130px" %)±2
20 -|(% style="width:472px" %)Dimensions (length × width × height), mm|(% style="width:130px" %)139 × 126 × 16
21 -|(% style="width:472px" %)Weight, g|(% style="width:130px" %)230 ± 5
22 -|(% style="width:472px" %)Operating temperature range, ºС|(% style="width:130px" %)-40 to +85
23 -|(% style="width:472px" %)Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|(% style="width:130px" %)3500
10 +(% style="width:628px" %)
11 +|(% style="width:472px" %)**Parameter**|(% style="width:151px" %)**Value**
12 +|(% style="width:472px" %)Supply voltage, V|(% style="width:151px" %)5.0 ± 0.5
13 +|(% style="width:472px" %)Current consumption @5 V, mA (typical)|(% style="width:151px" %)4
14 +|(% style="width:472px" %)Cell stack voltage, V|(% style="width:151px" %)10 to 80
15 +|(% style="width:472px" %)Power consumption @Cell stack, mW (maximum)|(% style="width:151px" %)175
16 +|(% style="width:472px" %)Number of cells|(% style="width:151px" %)4 to 12
17 +|(% style="width:472px" %)Balancing current @4.2 V on a cell, mA (average)|(% style="width:151px" %)350
18 +|(% style="width:472px" %)Cell voltage measurement error, V (maximum)|(% style="width:151px" %)±0.003
19 +|(% style="width:472px" %)Cell temperature measurement error, °С (maximum)|(% style="width:151px" %)±2
20 +|(% style="width:472px" %)Dimensions (length × width × height), mm|(% style="width:151px" %)139 × 126 × 16
21 +|(% style="width:472px" %)Weight, g|(% style="width:151px" %)230 ± 5
22 +|(% style="width:472px" %)Operating temperature range, ºС|(% style="width:151px" %)-40 to +85
23 +|(% style="width:472px" %)Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|(% style="width:151px" %)3500
24 +|Headers X1-X4 type|(% style="width:151px" %)Molex series Micro-Fit