Last modified by Admin on 2025/05/12 11:13

From version 1.1
edited by Admin
on 2024/12/02 12:10
Change comment: There is no comment for this version
To version 19.1
edited by Admin
on 2025/05/12 11:13
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -drafts.BMS Logic 12.WebHome
1 +Battery management systems.BMS Logic 12.WebHome
Content
... ... @@ -1,21 +1,30 @@
1 +(% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 += echnical specifications =
3 +
4 +[[image:1746620257874-435.png||data-xwiki-image-style-alignment="center" height="211" width="450"]]
5 +
1 1  BMS Logic 12 represents the second generation of measuring modules that takes the best from BMS Logic 2.0 and offers greater accuracy and energy efficiency. It determines voltage and temperature of the battery cells and does passive balancing of the cells on a command from the BMS controller.
2 2  
3 -== 1.1 Specifications ==
8 +== Specifications ==
4 4  
5 -|**Parameter**|**Value**
6 -|Supply voltage, V|5.0 ± 0.5
7 -|Current consumption @5 V, mA (typical)|4
8 -|Cell stack voltage, V|10 to 80
9 -|Power consumption @Cell stack, mW (maximum)|175
10 -|Number of cells|4 to 12
11 -|Balancing current @4.2 V on a cell, mA (average)|350
12 -|Cell voltage measurement error, V (maximum)|±0.003
13 -|Cell temperature measurement error, °С (maximum)|±2
14 -|Dimensions (length × width × height), mm|139 × 126 × 16
15 -|Weight, g|230 ± 5
16 -|Operating temperature range, ºС|-40 to +85
17 -|Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|3500
10 +(% style="width:628px" %)
11 +|(% style="width:472px" %)**Parameter**|(% style="width:151px" %)**Value**
12 +|(% style="width:472px" %)Supply voltage, V|(% style="width:151px" %)5.0 ± 0.5
13 +|(% style="width:472px" %)Current consumption @5 V, mA (maximum)|(% style="width:151px" %)10
14 +|(% style="width:472px" %)Cell stack voltage, V|(% style="width:151px" %)11 to 52
15 +|(% style="width:472px" %)Power consumption @Cell stack, mW (maximum)|(% style="width:151px" %)200
16 +|(% style="width:472px" %)Number of cells|(% style="width:151px" %)4 to 12
17 +|(% style="width:472px" %)Balancing current @4.2 V on a cell, mA (average)|(% style="width:151px" %)350
18 +|(% style="width:472px" %)Cell voltage measurement error, V (maximum)|(% style="width:151px" %)±0.003
19 +|(% style="width:472px" %)Cell temperature measurement error, °С (maximum)|(% style="width:151px" %)±2
20 +|(% style="width:472px" %)Dimensions (length × width × height), mm|(% style="width:151px" %)139 × 126 × 16
21 +|(% style="width:472px" %)Weight, g|(% style="width:151px" %)250 ± 20
22 +|(% style="width:472px" %)Operating temperature range, ºС|(% style="width:151px" %)-40 to +85
23 +|(% style="width:472px" %)Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, V,,RMS,, (minimum)|(% style="width:151px" %)3500
24 +|Headers X1-X4 type|(% style="width:151px" %)Molex series Micro-Fit
18 18  
19 -== 1.2 Overall and mounting dimensions ==
26 +== Overall and mounting dimensions ==
20 20  
21 -[[image:1733141406083-452.png||data-xwiki-image-style-border="true"]]
28 +[[image:1746622870523-241.png||data-xwiki-image-style-alignment="center" height="492" width="450"]]
29 +
30 +
1736773614836-174.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +42.5 KB
Content
1746619842455-105.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +16.5 KB
Content
1746620257874-435.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +521.7 KB
Content
1746622870523-241.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +16.7 KB
Content
1746622892783-944.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +16.7 KB
Content