Wiki source code of BMS LANmodule
Last modified by Admin on 2025/05/12 11:26
Hide last authors
author | version | line-number | content |
---|---|---|---|
![]() |
12.1 | 1 | = General information = |
![]() |
1.1 | 2 | |
3 | [[image:1734099407734-687.png||data-xwiki-image-style-alignment="center" height="167" width="300"]] | ||
4 | |||
![]() |
12.1 | 5 | BMS LANmodule is an extension module that can be inserted to the BMS Mini, BMS Mini S, BMS Main 3, BMS Main X, or BMS Main 3X controller. It allows a BMS controller to be configured over an Ethernet network. |
![]() |
1.1 | 6 | |
7 | (% id="cke_bm_4104S" style="display:none" %) (%%)Overall architecture of a battery system that is controlled by an upper-level system via Ethernet is shown below. | ||
8 | |||
![]() |
12.1 | 9 | [[image:1734099501895-554.png||data-xwiki-image-style-alignment="center" height="344" width="450"]] |
![]() |
1.1 | 10 | |
![]() |
12.1 | 11 | = Specifications = |
![]() |
1.1 | 12 | |
![]() |
12.1 | 13 | |**Parameter**|**Value** |
14 | |Supply voltage, V|5.0 ± 0.5 | ||
15 | |Current consumption, mA, max|200 | ||
16 | |Network speed, Mbps|10/100 | ||
17 | |Dimensions (length × width × height), mm|44 × 42 × 24 | ||
![]() |
16.1 | 18 | |Weight, g|14 ± 5 |
![]() |
12.1 | 19 | |(% colspan="2" %)**Operating conditions** |
20 | |Operating temperature range, ° С|-40 to +85 | ||
21 | |Degree of protection from external influences|IP00 | ||
![]() |
1.1 | 22 | |
![]() |
12.1 | 23 | = Connection procedure = |
![]() |
1.1 | 24 | |
25 | (% class="box warningmessage" %) | ||
26 | ((( | ||
![]() |
12.1 | 27 | **Attention!** |
![]() |
13.1 | 28 | Connecting the BMS LANmodule is performed to the powered-off BMS controller! |
![]() |
15.1 | 29 | To prevent the damage of device avoid electrostatic discharges. |
![]() |
1.1 | 30 | ))) |
31 | |||
![]() |
12.1 | 32 | The BMS LANmodule must be inserted into the corresponding header of the BMS controller. The device must be fixed to the BMS controller by **11mm M3 standoffs** and M3 screws. |
![]() |
1.1 | 33 | |
![]() |
12.1 | 34 | Here is the example of header for additional devices on BMS Main X: |
![]() |
1.1 | 35 | |
36 | [[image:1734099661846-836.png||data-xwiki-image-style-alignment="center" height="423" width="450"]] | ||
37 | |||
![]() |
12.1 | 38 | = Configuration = |
![]() |
1.1 | 39 | |
![]() |
12.1 | 40 | Configuration of the BMS LANmodule must be done according to the BMS controller’s configuration manual, see [[Battery management systems>>path:/bin/view/Battery%20management%20systems/]]. Typically, the connection settings located in the “Connectivity -> LAN” section of the settings. |
![]() |
1.1 | 41 | |
![]() |
13.1 | 42 | (% class="box infomessage" %) |
![]() |
1.1 | 43 | ((( |
![]() |
12.1 | 44 | To apply new connection settings, it is necessary to restart the BMS controller. |
![]() |
1.1 | 45 | ))) |